1.
Sensors (Basel) ; 23(1)2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36616996

RESUMO

This paper presents the measurement methodology of diameter reduction monitoring of micro-tunnel structures used for radioactive waste storage based on distributed strain measurements along fiber optic sensors installed on the circumference. The whole measurement procedure is described: the calibration of the sensors for use in harsh environment (temperature and radioactivity), the measurement analysis technique, the performance assessment of different measurement systems on a surface mock-up and the in-situ validation on an underground structure. The performances of Brillouin and Rayleigh backscattering measurements are compared, as well as different fixation technologies. Distributed measurements are compared to alternative measurements: displacement sensors, Bragg grating extensometers and MEMS accelerometers. The distributed Rayleigh backscattering measurement performed on optical cables bonded to the surface of the structure appears to be the best solution for monitoring the convergence of micro-tunnels and offers comparable performance to alternative technologies tested on the surface demonstrator.


Assuntos
Fibras Ópticas , Resíduos Radioativos , Tecnologia de Fibra Óptica/métodos , Calibragem , Transdutores
2.
Sensors (Basel) ; 20(3)2020 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-32012773

RESUMO

Optical fiber strain sensing cables are widely used in structural health monitoring; however, the impact of a harsh environment on them is not assessed despite the huge importance of the stable performances of the monitoring systems. This paper analyzes (i) the impact of the different constituent layers on the behavior of a strain sensing cable whose constitutive materials are metal and polyamide, (ii) the radiation influence on the optical fiber strain sensing cable response (500 kGy of γ -rays), and (iii) the behavior of the cable under high axial strain (up to 1%, 10,000 µ ε ). Radiation impact on strain sensitivity is negligible for practical application, i.e., the coefficient changes by 4% at the max. The influence of the composition of the cable is also assessed: the sensitivity differences remain under 15%, a standard variation range when different cable compositions and structures are considered. The elasto-plastic behavior is at the end evaluated, highlighting the residual strain (about 1600 µ ε after imposing 10,000 µ ε ) of the cable (especially for metallic parts).

3.
Opt Express ; 27(20): 29026-29033, 2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31684644

RESUMO

We have designed and implemented a fiber optic shape sensor for high-energy ionizing environments based on multicore optical fibers. We inscribed two fiber Bragg gratings arrays in a seven-core optical fiber. One of the arrays has been inscribed in a hydrogen-loaded fiber and the other one in an unloaded fiber in order to have two samples with very different radiation sensitivity. The two samples were coiled in a metallic circular structure and were exposed to gamma radiation. We have analyzed the permanent radiation effects. The radiation-induced Bragg wavelength shift (RI-BWS) in the hydrogen-loaded fiber is near ten times higher than the one observed for the unloaded fiber, with a maximum wavelength shift of 415 pm. However, the use of the multiple cores permits to make these sensors immune to RI-BWS obtaining a similar curvature error in both samples of approximately 1 cm without modifying the composition of the fiber, pre-irradiation or thermal treatment.

4.
Sensors (Basel) ; 17(6)2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28608831

RESUMO

This paper presents the state of the art distributed sensing systems, based on optical fibres, developed and qualified for the French Cigéo project, the underground repository for high level and intermediate level long-lived radioactive wastes. Four main parameters, namely strain, temperature, radiation and hydrogen concentration are currently investigated by optical fibre sensors, as well as the tolerances of selected technologies to the unique constraints of the Cigéo's severe environment. Using fluorine-doped silica optical fibre surrounded by a carbon layer and polyimide coating, it is possible to exploit its Raman, Brillouin and Rayleigh scattering signatures to achieve the distributed sensing of the temperature and the strain inside the repository cells of radioactive wastes. Regarding the dose measurement, promising solutions are proposed based on Radiation Induced Attenuation (RIA) responses of sensitive fibres such as the P-doped ones. While for hydrogen measurements, the potential of specialty optical fibres with Pd particles embedded in their silica matrix is currently studied for this gas monitoring through its impact on the fibre Brillouin signature evolution.

5.
Sensors (Basel) ; 17(2)2017 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-28218652

RESUMO

We investigated the evolution of the performances of Pulse Pre Pump-Brillouin Time Domain Analysis (PPP-BOTDA) and Tunable Wavelength Coherent Optical Time Domain Reflectometry (TW-COTDR) fiber-based temperature and strain sensors when the sensing optical fiber is exposed to two γ-ray irradiation conditions: (i) at room temperature and a dose rate of 370 Gy(SiO2)/h up to a total ionizing dose (TID) of 56 kGy; (ii) at room temperature and a dose rate of 25 kGy(SiO2)/h up to a TID of 10 MGy. Two main different classes of single-mode optical fibers have been tested in situ, radiation-tolerant ones: fluorine-doped or nitrogen-doped core fibers, as well as Telecom-grade germanosilicate ones. Brillouin and Rayleigh Sensitivities of N-Doped fibers were not reported yet, and these characterizations pave the way for a novel and alternative sensing scheme. Moreover, in these harsh conditions, our results showed that the main parameter affecting the sensor sensitivity remains the Radiation Induced Attenuation (RIA) at its operation wavelength of 1550 nm. RIA limits the maximal sensing range but does not influence the measurement uncertainty. F-doped fiber is the most tolerant against RIA with induced losses below 8 dB/km after a 56 kGy accumulated dose whereas the excess losses of other fibers exceed 22 dB/km. Both Rayleigh and Brillouin signatures that are exploited by the PPP-BOTDA and the TW-COTDR remain unchanged (within our experimental uncertainties). The strain and temperature coefficients of the various fibers under test are not modified by radiations, at these dose/dose rate levels. Consequently, this enables the design of a robust strain and temperature sensing architecture for the monitoring of radioactive waste disposals.

6.
Sensors (Basel) ; 16(4)2016 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-27096865

RESUMO

Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling.

7.
Opt Express ; 20(24): 26978-85, 2012 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-23187553

RESUMO

The use of distributed strain and temperature in optical fiber sensors based on Brillouin scattering for the monitoring of nuclear waste repository requires investigation of their performance changes under irradiation. For this purpose, we irradiated various fiber types at high gamma doses which represented the harsh environment constraints associated with the considered application. Radiation leads to two phenomena impacting the Brillouin scattering: 1) decreasing in the fiber linear transmission through the radiation-induced attenuation (RIA) phenomenon which impacts distance range and 2) modifying the Brillouin scattering properties, both intrinsic frequency position of Brillouin loss and its dependence on strain and temperature. We then examined the dose dependence of these radiation-induced changes in the 1 to 10 MGy dose range, showing that the responses strongly depend on the fiber composition. We characterized the radiation effects on strain and temperature coefficients, dependencies of the Brillouin frequency, providing evidence for a strong robustness of these intrinsic properties against radiations. From our results, Fluorine-doped fibers appear to be very promising candidates for temperature and strain sensing through Brillouin-based sensors in high gamma-ray dose radiative environments.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Raios gama , Fibras Ópticas , Radiometria/métodos , Refratometria/instrumentação , Espalhamento de Radiação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento