Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Pharm ; 592: 120056, 2021 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-33161035

RESUMO

Currently, there is a need for new technology for in-line or fast at-line assessment of solid material porosity. One specific gap is a fast technology to be used in connection to roller compaction (RC) manufacturing, where the porosity of the RC ribbons is critical to the manufacturing of tablets of the right tensile strength and disintegration properties. In this paper, the development of an at-line technology for fast, non-destructive assessment of porosity of RC ribbons is reported. The technology is based on a diode laser spectroscopic technique called Gas in scattering media absorption spectroscopy (GASMAS). GASMAS measures the sample voids by laser light, giving the distance through air. The total distance the light travels is measured using time-of-flight spectroscopy (TOFS). The ratio of these measures gives an "optical porosity", which through theory relates to the porosity of the sample. We present a description of the technology, evaluations of measurement robustness and results from an experimental design where roller compactor, roll force, roll gap and formulation were varied. It is concluded that the data from two different pharmaceutical formulations is supported by the same calibration curve, which indicates that optical porosimetry is a general technique for pharmaceutical materials that does not require frequent calibrations.


Assuntos
Gases , Tecnologia Farmacêutica , Composição de Medicamentos , Porosidade , Análise Espectral , Comprimidos , Resistência à Tração
2.
J Biophotonics ; 12(8): e201800350, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30993871

RESUMO

Oxygen and water vapor content, in the lungs of a 3D-printed phantom model based on CT-images of a preterm infant, is evaluated using Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Gas in Scattering Media Absorption Spectroscopy (GASMAS), that is, the TDLAS-GASMAS technique. Oxygen gas is detected through an absorption line near 764 nm and water vapor through an absorption line near 820 nm. A model with a lung containing interior structure is compared to a model with a hollow lung. Compared to the model with the hollow lung, both the mean absorption path length and the transmitted intensity are found to be lower for the model with the structured lung. A new approach, where laser light is delivered internally into the model through an optical fiber, is compared to dermal light administration, that is, illumination onto the skin, for the model with structure inside the lung. The internal light administration generally resulted in larger gas absorption, and higher signal-to-noise ratios, compared to the dermal light administration. The results from the phantom measurements show great promise for the internal illumination approach and a natural next step would be to investigate it further in clinical studies.


Assuntos
Absorção Fisico-Química , Luz , Pulmão/metabolismo , Pulmão/efeitos da radiação , Imagens de Fantasmas , Pele , Análise Espectral , Humanos , Fibras Ópticas , Oxigênio/metabolismo , Impressão Tridimensional
3.
J Biophotonics ; 11(11): e201800023, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29978572

RESUMO

Further improvements in the clinical care of our most vulnerable patients-preterm infants-are needed. Novel diagnostic and surveillance tools facilitate such advances. The GASMAS technique has shown potential to become a tool to, noninvasively, monitor gas in the lungs of preterm infants, by placing a laser source and a detector on the chest wall skin. It is believed that this technology will become a valuable clinical diagnostic tool for monitoring the lung function of these patients. Today, the technology is, for this application, in an early stage and further investigations are needed. In the present study, a three-dimensional computer model of the thorax of an infant is constructed, from a set of CT images. Light transport simulations are performed to provide information about the position dependence of the laser- and detector probe on the thorax of the infant. The result of the simulations, based on the study method and the specified model used in this work, indicates that measurement geometries in front and on the side of the lung are favorable in order to obtain a good gas absorption signal.


Assuntos
Simulação por Computador , Imageamento Tridimensional , Recém-Nascido Prematuro/metabolismo , Pulmão/diagnóstico por imagem , Pulmão/metabolismo , Oxigênio/metabolismo , Pele , Humanos , Lactente , Modelos Biológicos , Tomografia Computadorizada por Raios X
4.
J Biophotonics ; 11(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28816029

RESUMO

There is a need to further improve the clinical care of our most vulnerable patients-preterm infants. Novel diagnostic and treatment tools facilitate such advances. Here, we evaluate a potential percutaneous optical monitoring tool to assess the oxygen and water vapor content in the lungs of preterm babies. The aim is to prepare for further clinical studies by gaining a detailed understanding of how the measured light intensity and gas absorption signal behave for different possible geometries of light delivery and receiver. Such an experimental evaluation is conducted for the first time utilizing a specially developed 3-dimensional-printed optical phantom based on a geometry model obtained from computer tomography images of the thorax (chest) of a 1700-g premature infant. The measurements yield reliable signals for source-detector distances up to about 50 mm, with stronger gas absorption signals at long separations and positions related to the lower part of the lung, consistent with a larger relative volume of this. The limitations of this study include the omission of scattering tissue within the lungs and that similar optical properties are used for the wavelengths employed for the 2 gases, yielding no indication on the optimal wavelength pair to use.


Assuntos
Recém-Nascido Prematuro/metabolismo , Lasers , Pulmão/diagnóstico por imagem , Oxigênio/metabolismo , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Recém-Nascido , Pulmão/metabolismo , Vapor
5.
J Biomed Opt ; 18(12): 127005, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24362929

RESUMO

Preterm newborn infants have a high morbidity rate. The most frequently affected organs where free gas is involved are the lungs and intestines. In respiratory distress syndrome, both hyperexpanded and atelectatic (collapsed) areas occur, and in necrotizing enterocolitis, intramural gas may appear in the intestine. Today, these conditions are diagnosed with x-ray radiography. A bed-side, rapid, nonintrusive, and gas-specific technique for in vivo gas sensing would improve diagnosis. We report the use of noninvasive laser spectroscopy, for the first time, to assess gas content in the lungs and intestines of three full-term infants. Water vapor and oxygen were studied with two low-power diode lasers, illuminating the skin and detecting light a few centimeters away. Water vapor was easily detected in the intestines and was also observed in the lungs. The relatively thick chest walls of the infants prevented detection of the weaker oxygen signal in this study. However, results from a previous phantom study, together with scaling of the results presented here to the typical chest-wall thickness of preterm infants, suggest that oxygen also should be detectable in their lungs.


Assuntos
Gases/análise , Intestinos/fisiologia , Lasers Semicondutores , Pulmão/fisiologia , Monitorização Fisiológica/instrumentação , Análise Espectral/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Lactente , Recém-Nascido , Intestinos/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Masculino , Monitorização Fisiológica/métodos , Imagens de Fantasmas , Análise Espectral/métodos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...