Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Colloids Surf B Biointerfaces ; 113: 213-22, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24103502

RESUMO

Despite extensive use of polyetheretherketone (PEEK) in biomedical applications, information about bacterial adhesion to this biomaterial is limited. This study investigated Staphylococcus aureus and Staphylococcus epidermidis adhesion to injection moulded and machined PEEK OPTIMA(®) using a custom-built adhesion chamber with medical grade titanium and Thermanox for comparison. Additionally, bacterial adhesion to a novel oxygen plasma modified PEEK was also investigated in both a pre-operative model in physiological saline, and additionally in a post-operative model in human blood plasma. In the pre-operative model, the rougher machined PEEK had a significantly greater number of adherent bacteria compared to injection moulded PEEK. Bacterial adhesion to titanium and Thermanox was similar. Oxygen plasma surface modification of PEEK did not lead to a significant change in bacterial adhesion in the pre-operative contamination model, despite observed changes in surface characteristics. In the post-operative contamination model, S. aureus adhesion was increased from 5×10(5) CFU cm(-2) to approximately 1.3×10(7) CFU cm(-2) on the modified surfaces due to differential protein adhesion during the conditioning period. However, S. epidermidis adhesion to modified PEEK was less than to unmodified PEEK in the post-operative model. These results illustrate the importance of testing bacterial adhesion of several strains in both a pre-operative and post-operative, clinically relevant bacterial contamination model.


Assuntos
Oxigênio/farmacologia , Titânio/química , Aderência Bacteriana/efeitos dos fármacos , Benzofenonas , Materiais Biocompatíveis/química , Cetonas/química , Cetonas/farmacologia , Oxigênio/química , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Polímeros , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus epidermidis/efeitos dos fármacos
2.
Acta Biomater ; 6(9): 3808-12, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20230921

RESUMO

In this study, a composite porous material obtained by coating a poly(ester urethane) foam with a calcium phosphate cement is proposed as novel cancellous bone filler with easy handling, in situ hardening and press-fitting properties. The coating can be applied to the foam in the surgical theater, allowing refinement of scaffold shape to the needs of the ongoing surgery. An innovative experiment was developed in order to determine the setting curve of the composite scaffold as well as the time of manipulation available to the surgeon without risk of material damage. This composite material is soft and can be press-fit in a cavity without damaging the scaffold in the first 5 min after coating application. The composite scaffold hardens quickly (22 min) and, once the cement has set, its compressive strength and fracture energy are increased by over an order of magnitude as compared to the initial poly(ester urethane) foam. This set of interesting properties makes calcium phosphate cement-coated elastomeric scaffolds a new promising strategy for cancellous bone filling.


Assuntos
Substitutos Ósseos/análise , Osso e Ossos/patologia , Teste de Materiais/métodos , Alicerces Teciduais/química , Cicatrização , Dureza , Microscopia Eletrônica de Varredura , Porosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...