1.
J Orthop Res ; 21(2): 189-95, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12568948

RESUMO

BACKGROUND: Metal-on-metal total hip prostheses will produce a certain amount of wear debris. This results in increased whole-blood metal levels, which may cause adverse effects. It is not known to what extent the problem has been overcome by advances in alloy technology. METHODS: In 259 patients who with total hip replacement, blood cobalt and chromium concentrations were measured with atomic absorption spectrophotometry over a period of four years after arthroplasty. Of the patients enrolled in the study, 131 had been managed with a METASUL cobalt-chromium alloy metal-on-metal bearing combination, while 128 had been given a SIKOMET-SM21 cobalt-chromium alloy metal-on-metal combination. The control group consisted of 31 age- and gender-matched subjects. RESULTS: Compared with the controls, all the patients had higher cobalt and chromium levels. Cobalt concentrations were up to 50 times higher, while chromium concentrations were up to 100 times higher. CONCLUSIONS: Both systems showed evidence, in the whole-blood samples, of wear debris production by the implants. Therefore, patients managed with metal-on-metal bearing combinations should be carefully monitored in order to ensure that any local or systemic complications are detected early on.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Complicações Pós-Operatórias , Cromo/análise , Ligas de Cromo , Cobalto/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espectrofotometria Atômica , Fatores de Tempo
2.
Biomaterials ; 24(6): 1081-91, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12504531

RESUMO

A tribologic assessment was performed on 22 metal-metal hip prostheses from a single manufacturer, following removal for early aseptic loosening after a mean service life of 32 months (range, 12-59 months). The mean linear wear rate was 7.6 microm/year (range, 2.9-12.8 microm/year). This was below the rates previously observed in other modern metal-metal combinations. A novel contour analysis technique using a coordinate measuring machine showed the mean volumetric wear rate to be 2.02 mm(3)/year (range, 0.55-3.74 mm(3)/year), which corresponds to a mean gravimetric wear rate of 16.9 mg/year (range, 4.6-31.4 mg/year). The mean clearance of 39.8 microm (range, 30-50 microm) was within the optimal range for hard-hard bearing combinations. Evidence of abrasive, adhesive, and third-body wear was found on all bearing surfaces. The tribologic assessment did not indicate manufacturing defects as a cause of early loosening. Equally, third-body wear was too low to be considered a causative factor for early loosening.


Assuntos
Ligas , Prótese de Quadril , Metais , Falha de Prótese , Artroplastia de Quadril , Cimentos Ósseos , Fêmur , Humanos , Microscopia Eletrônica de Varredura , Fatores de Tempo , Difração de Raios X