Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38930257

RESUMO

This study concerned the in situ investigation of the defect evolution and fracture mechanism of additively manufactured (AM) Ti-6Al-4V under uniaxial tensile tests. In order to achieve this, microstructure characterization was initially carried out in order to identify the defects within the matrix of the candidate material. In situ testing was then performed, focusing on the spherical defect to observe its evolution under tensile loading. It was found that, before the fracture stage, the geometric evolution of the spherical defect towards an ellipse shape was dominated by the load in the tensile direction. In addition, the slip band density was found to be aggravated near the spherical defect due to the geometric discontinuity-induced stress concentration. During the fracture process, the defect geometry evolved as an irregular shape, which was mainly attributed to the micro-void-induced localized multi-axial stress state. The fracture analysis indicated that defects play a key role in crack initiation, leading to the fracture of LPBF materials.

2.
J Mech Behav Biomed Mater ; 146: 106058, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37549521

RESUMO

Recently, additive manufacturing (AM) has been investigated as an innovative method to manufacture stents due to its capability in producing complex and customized structures. In this paper, the cardiovascular stents of M-type and N-type with inverse unequal height strut structure and N-type with equal height strut structure were designed and manufactured by Selective Laser Melting (SLM). Following surface polishing, balloon expansion, plane compression and three-point bending experiments were carried out to evaluate the mechanical performance of the stent. The stents designed with inverse unequal height strut structure showed higher radial support performance and lower radial recoil when compared to the stents with uniform design. This study proved the feasibility of SLM in rapid manufacturing of cardiovascular stents that can be used for performance evaluation in design stage.


Assuntos
Sistema Cardiovascular , Stents , Estresse Mecânico , Pressão , Desempenho Físico Funcional , Desenho de Prótese
3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(3): 552-558, 2023 Jun 25.
Artigo em Chinês | MEDLINE | ID: mdl-37380396

RESUMO

The interventional therapy of vascular stent implantation is a popular treatment method for cardiovascular stenosis and blockage. However, traditional stent manufacturing methods such as laser cutting are complex and cannot easily manufacture complex structures such as bifurcated stents, while three-dimensional (3D) printing technology provides a new method for manufacturing stents with complex structure and personalized designs. In this paper, a cardiovascular stent was designed, and printed using selective laser melting technology and 316L stainless steel powder of 0-10 µm size. Electrolytic polishing was performed to improve the surface quality of the printed vascular stent, and the expansion behavior of the polished stent was assessed by balloon inflation. The results showed that the newly designed cardiovascular stent could be manufactured by 3D printing technology. Electrolytic polishing removed the attached powder and reduced the surface roughness Ra from 1.36 µm to 0.82 µm. The axial shortening rate of the polished bracket was 4.23% when the outside diameter was expanded from 2.42 mm to 3.63 mm under the pressure of the balloon, and the radial rebound rate was 2.48% after unloading. The radial force of polished stent was 8.32 N. The 3D printed vascular stent can remove the surface powder through electrolytic polishing to improve the surface quality, and show good dilatation performance and radial support performance, which provides a reference for the practical application of 3D printed vascular stent.


Assuntos
Sistema Cardiovascular , Aço Inoxidável , Humanos , Pós , Constrição Patológica
4.
Materials (Basel) ; 16(4)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36837191

RESUMO

In this paper, the abnormal fracture failure of a ZL104 aluminum alloy quick-opening manhole cover of a cement tank truck is systematically studied to discover the root cause of an accident. The unloading operation procedures of cement tank trucks, the effectiveness of safety valves, the chemical composition, mechanical properties and material quality of aluminum alloy manhole covers, and the macroscopic and microscopic morphology of fractures were comprehensively analyzed. The results show that although the Mg content in the chemical composition of an aluminum alloy manhole cover exceeds the standard, it is not the root cause of the accident. The root cause of the failure is that, during the unloading operation, the operator did not strictly follow the unloading procedures. One of the buckles was in the released state, which led to uplift cracking, resulting in the successive cracking and slipping of adjacent buckles, and the manhole cover finally cracked and flew out. Based on the failure causes, suggestions are put forward to prevent the manhole cover from failing during the unloading operation of cement tank trucks in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA