Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Ann Med ; 55(2): 2272711, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37883811

RESUMO

Objective: To realize the changes in pulmonary hypertension (PH) patients' right ventricular function.Methods: A total number of 74 patients with PH were included, and the parameters of standard echocardiographic were measured as well as the strain of peak longitudinal of each segment during the systole of the right ventricle to calculate the global longitudinal strain (LS) during systole of the right ventricular free wall.Results: ① As pulmonary arterial pressure increased, the right ventricular area gradually increased, and the case group showed the decreased right ventricular fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE), and tricuspid annular peak systolic velocity (S') (p < 0.05). They, RVFAC, and TAPSE depicted significant differences that were statistical (p < 0.05) from the other groups. ② With increasing pulmonary arterial pressure, the right ventricular free wall's LS gradually reduced (p < 0.05).Conclusion: ① LS right ventricular free wall is useful in detecting changes in right ventricular systolic function early on with greater sensitivity than RVFAC, TAPSE, and S'. In addition, increased right ventricular pressure loading can result in a subsequent impairment of right ventricular myocardial mechanics. ② As right ventricular pressure loading increases, right ventricular strain decreases. ③ In mild PH, the right ventricular free wall's. LS is more sensitive than standard measures in spotting early alterations in myocardial mechanics.


Assuntos
Hipertensão Pulmonar , Humanos , Estudos Retrospectivos , Hipertensão Pulmonar/diagnóstico por imagem , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Sístole
2.
Front Endocrinol (Lausanne) ; 14: 1161424, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37378021

RESUMO

Objectives: Differential diagnosis of benign and malignant thyroid imaging reporting and data system (TIRADS) category 4a and 4b nodules can be difficult using conventional ultrasonography (US). The objective of this study was to evaluate the diagnostic efficacy of a combination of the Chinese-TIRADS (C-TIRADS) and shear wave elastography (SWE) in detecting malignant nodules among category 4a and 4b thyroid nodules. Methods: Among 409 thyroid nodules in 332 patients that we included in this study, 106 thyroid nodules were diagnosed as category 4a and 4b using C-TIRADS. We used SWE to measure the maximum Young's modulus (Emax) values of category 4a and 4b thyroid nodules. We calculated the diagnostic efficacy of only the C-TIRADS, only SWE, and a combination of C-TIRADS with SWE, and compared these, while taking the pathology results as the gold standard. Results: The area under the ROC curve (AUC), sensitivity, and accuracy values of the combination of C-TIRADS and SWE (0.870, 83.3%, and 84.0%, respectively) were all higher when compared with the values of only the C-TIRADS (0.785, 68.5%, and 78.3%, respectively) or only SWE (0.775, 68.5%, and 77.4%, respectively) in the diagnosis of category 4a and 4b thyroid nodules. Conclusion: In this study, we found that the combination of C-TIRADS and SWE significantly improved the diagnostic efficacy in detecting malignant nodules among category 4a and 4b thyroid nodules, and this could provide a reference for further use of this combination by clinicians for diagnosis and treatment.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Humanos , Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos
3.
Abdom Radiol (NY) ; 48(6): 2085-2090, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36943422

RESUMO

PURPOSE: Hepatocirrhotic nephropathy progresses rapidly and has a poor prognosis, and early detection of renal changes in patients with cirrhosis is particularly important for its prevention and treatment. The objective of this study was to evaluate the value of shear wave elastography (SWE) in the early diagnosis of hepatocirrhotic nephropathy. METHODS: 206 hepatic cirrhosis patients with normal conventional renal function were enrolled and divided into Child-Pugh grade A (Group A), Child-Pugh grade B (Group B), and Child-Pugh grade C (Group C) according to the Child-Pugh grading method. Meanwhile, 60 healthy volunteers matched in age and sex were selected as the control group. The maximum Young's modulus (Emax), average Young's modulus (Emean), and minimum Young's modulus (Emin) of the left renal parenchyma were measured by SWE in all subjects. The Emax, Emean, and Emin values of the left renal parenchyma were compared between the cirrhosis and control groups. RESULTS: The Emax, Emean, and Emin values of left renal parenchyma in cirrhosis group were higher than those in control group (p = 0.00, 0.00, 0.00). The Emax, Emean, and Emin values of left renal parenchyma in cirrhosis group B and group C were higher than those in control group (p = 0.00, 0.00, 0.00; p = 0.00, 0.00, 0.00), but these values in cirrhosis group A were not significantly different from control group(p = 0.48, 0.52, 0.92). Comparison of the Emax, Emean, and Emin values in left renal parenchyma of three cirrhosis groups, the values of Group B and Group C were higher than those of Group A (p = 0.00, 0.00, 0.00; p = 0.00, 0.00, 0.00), and there was no significant difference between Group B and Group C (p = 0.71, 0.18, 0.39). CONCLUSION: SWE can detect renal tissue damage in patients with liver cirrhosis earlier than changes identified during routine laboratory examination by quantitatively measuring the elastic parameters of renal parenchyma and may become a new method for early diagnosis of hepatorenal syndrome.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Rim/diagnóstico por imagem , Voluntários Saudáveis
4.
Front Endocrinol (Lausanne) ; 13: 858565, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35757426

RESUMO

Objective: To analyze the ultrasonic characteristics of false-negative and false-positive results of shear wave elastography (SWE) in the diagnosis of thyroid nodules to clarify the influence of nodular characteristics on SWE and to guide the clinical application of SWE. Methods: A total of 435 thyroid nodules from 343 patients with the diagnosis confirmed by surgical pathology were analyzed. Preoperative ultrasonography and SWE were conducted. The conventional ultrasound characteristics of thyroid nodules and the maximum Young's modulus were recorded. The false negativity and false positivity of SWE for the diagnosis of thyroid nodules were calculated. The ultrasonic characteristics of thyroid nodules with SWE false results were analyzed, and logistic regression analysis was adopted to determine the ultrasonic characteristics associated with SWE false results of thyroid nodules. Results: Among 323 malignant nodules, the SWE false negativity was 27.2% (88/323). The false positivity of SWE in 112 benign nodules was 19.6% (22/112). Regression analysis showed that an increase in the nodule volume increased the risk of SWE false-positive results (odds ratio [OR] 3.286; 95% confidence interval [CI]: 1.572-6.871; P = 0.002) and decreased the risk of false-negative results (OR 0.238; 95% CI: 0.115-0.493; P < 0.001). Nodules with coarse calcification had an increased risk of SWE false-positive results compared with those without calcification (OR 5.303; 95% CI: 1.098-25.619; P = 0.038). However, nodules with scattered hyperechoic foci had a reduced risk of SWE false-negative results (OR 0.515; 95% CI: 0.280-0.951; P = 0.034). Conclusion: Nodular size and calcification were correlated with SWE false results, and the clinical application of SWE should be combined with conventional ultrasound features. Fine needle aspiration or a puncture biopsy should be conducted if necessary.


Assuntos
Calcinose , Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Biópsia por Agulha Fina , Técnicas de Imagem por Elasticidade/métodos , Humanos , Reprodutibilidade dos Testes , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos
5.
Int J Gen Med ; 14: 8007-8018, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34785943

RESUMO

OBJECTIVE: To evaluate the clinical value of qualitative shear wave elastography (SWE) color in the differential diagnosis of benign and malignant thyroid nodules. METHODS: From January 2017 to July 2018, 241 patients with 261 thyroid nodules, who underwent conventional ultrasonography and SWE examination before surgical resection, were enrolled. The nodules were also evaluated by histopathologic analyses. The SWE color characteristics that could differentiate malignant and benign thyroid nodules were selected and scored based on the malignancy rate. The diagnostic performances were evaluated by receiver operating characteristic (ROC) curves analysis. RESULTS: Among the 261 thyroid nodules, 58 were benign, and 203 were malignant. Malignancy was associated with orange or red as the color of maximum hardness inside a nodule, green as the primary color, with a "stiff rim," inhomogeneous internal color, and inhomogeneous color between the nodules and its surrounding areas. The SWE color scores for benign thyroid nodules were mainly 0 and 1, while 4 and 5 were for malignant thyroid nodules. The area under the ROC curve (AUC) of the SWE color score ≥3 for the diagnosis of malignant thyroid nodules was 0.828 (95% CI: 0.764, 0.891) with a sensitivity of 82.8%, a specificity of 82.8%, and an accuracy of 83.1%. Additionally, conventional ultrasound combined with SWE color scores had a higher diagnostic performance than conventional ultrasound (AUC 0.820 vs AUC 0.796, P = 0.04). CONCLUSION: The SWE color scores might be a convenient and effective method to assist in differentiating thyroid nodules.

6.
Sci Rep ; 11(1): 21616, 2021 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-34732826

RESUMO

In shear wave elastography (SWE) studies, the optimal cutoff value of Young's modulus for the diagnosis of benign and malignant thyroid nodules varies greatly, which affects the clinical application of the method. The objective of this study was to evaluate the influence of thyroid nodule size on the clinical diagnostic efficacy of SWE. A total of 356 thyroid nodules of 280 patients were divided into three groups according to size (Group A: ≤ 1 cm; Group B: 1-2 cm; Group C: ≥ 2 cm). SWE was used to measure the maximum Young's modulus (Emax) values of all thyroid nodules. Receiver operating characteristic (ROC) curves were drawn with pathological results as the gold standard. For all nodules, the optimal cutoff value of Emax in SWE for diagnosing malignant thyroid nodules was 36.2 kPa. The sensitivity and specificity were 76.5% and 78.4%, respectively. Groups A, B, and C had different optimal Emax cutoff values of 33.7 kPa, 37.7 kPa, and 55.1 kPa, respectively. The area under the ROC curve (AUC) values of Groups A, B, and C (0.844, 0.886, and 0.935, respectively) were all greater than the values for all lesions (0.830). The specificity values of Groups A, B, and C (86.4%, 82.6%, and 88.2%, respectively) were all increased, and the sensitivity values of Groups B and C (89.7% and 96.4%, respectively) were also increased compared with the values for all lesions. Thyroid nodule size affects the optimal Emax cutoff value of SWE. We suggest that different cutoff values be used to diagnose benign and malignant thyroid nodules according to lesion size.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/diagnóstico , Adulto , Idoso , Biópsia por Agulha Fina , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Adulto Jovem
7.
Surg Oncol ; 36: 1-6, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33271464

RESUMO

OBJECTIVE: To investigate the relationship between shear wave elastography (SWE) elasticity indices of papillary thyroid carcinoma (PTC) and central lymph node metastasis (CLNM) and to evaluate the value of SWE combined with gray-scale ultrasound (US) for predicting preoperative CLNM. METHOD: This study included 172 patients with a pathology diagnosis of PTC who underwent preoperative gray-scale US and SWE evaluation. Patients were divided into CLNM-positive and CLNM-negative groups. We analyzed the association between SWE elasticity indices (Emax, Emean and Emin) and CLNM, compared the diagnostic efficacy of gray-scale US alone versus SWE combined with gray-scale US for predicting CLNM, and analyzed the influence of Hashimoto's thyroiditis (HT) on the diagnostic efficacy of CLNM. RESULTS: SWE elasticity values Emax, Emean and Emin were significantly higher in CLNM-positive patients (P=0.000, 0.000 and 0.003, respectively). The AUC of Emax was higher than that of other SWE indices for predicting CLNM (AUC = 0.749; 95% CI = 0.676-0.822). In multivariate analysis, microcalcification (OR = 5.254; 95% CI = 2.496-11.061), extrathyroidal extension (OR = 4.210; 95% CI = 1.423-12.456), multifocality (OR = 3.084; 95% CI = 1.190-7.991) and Emax >59.0 kpa (OR = 4.934; 95% CI = 2.318-10.500) were independent risk factors for predicting CLNM. The AUC of SWE combined with gray-scale US for predicting CLNM (AUC = 0.825; 95% CI = 0.760-0.879) was significantly higher (P = 0.011) than that for gray-scale US alone (AUC = 0.774; 95% CI = 0.704-0.834). There was no significant difference in AUC between the HT and non-HT subgroups in predicting CLNM (0.798 vs. 0.833, P = 0.640). CONCLUSIONS: SWE can be used to predict CLNM in PTC patients. SWE combined with gray-scale US can improve the prediction of CLNM.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Metástase Linfática/patologia , Câncer Papilífero da Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Ultrassonografia/métodos , Humanos , Metástase Linfática/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem
8.
Biomed Res Int ; 2017: 5782619, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28808660

RESUMO

[This corrects the article DOI: 10.1155/2016/2643862.].

9.
Biomed Res Int ; 2016: 2643862, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27069921

RESUMO

OBJECTIVE: The aim of our study was to investigate the value of intraoperative contrast enhanced ultrasound (CEUS) for evaluating the grade of glioma and the correlation between microvessel density (MVD) and vascular endothelial growth factor (VEGF). METHODS: We performed intraoperative conventional ultrasound (CUS) and CEUS on 88 patients with gliomas. All of the patients have undergone surgery and obtained the results of pathology. All patients have undergone intraoperative CUS and CEUS to compare the characteristics of different grade gliomas and the results of CUS and CEUS were compared with pathological results. RESULTS: The time to start (TTS) and time to peak (TTP) of low grade glioma (LGG) were similar to those of edema and normal brain surrounding glioma. The enhanced extent of LGG was higher than that of the normal brain and edema. The TTS and TTP of high grade glioma were earlier than those of the edema and normal brain surrounding glioma. The enhancement of HGG was higher than that of LGG. The absolute peak intensity (API) was correlated with MVD and VEGF. CONCLUSION: Intraoperative CEUS could help in determining boundary of peritumoral brain edema of glioma. Intraoperative CEUS parameters in cerebral gliomas could indirectly reflect the information of MVD and VEGF.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Glioma/diagnóstico por imagem , Glioma/patologia , Cuidados Intraoperatórios/métodos , Gradação de Tumores/métodos , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Clin Imaging ; 37(6): 983-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24035526

RESUMO

OBJECTIVE: The objective was to assess intraoperative contrast-enhanced ultrasound (CEUS) in traumatic brain surgery. METHODS: We prospectively performed intraoperative conventional ultrasound (IOUS) and CEUS in 32 patients who underwent emergency surgery for the treatment of traumatic brain injury (TBI). Sonographic appearance including echogenicity, border, and size of the traumatic lesion and adjacent brain tissue on CEUS were compared with those on IOUS using surgical results as the gold standard. The differences in the size and contrast enhancement parameters of the lesions between IOUS and CEUS were analyzed with a paired t test. RESULTS: The accuracy of CEUS in assessing TBI was 100%, whereas IOUS was 51%. The absolute peak intensity (API) varied depending on the severity of brain injury. Lower API was observed in severely damaged brain tissue, whereas high API was seen in normal brain tissue or the brain tissue with mild injury. The border of the trauma lesion was more clearly defined on CEUS when compared to IOUS. The size of the lesions measured on CEUS was significantly larger than that on IOUS (P<.01). Importantly, small vessels supplying blood to the tissue in traumatic lesions, as an indication of possible brain vitality, were optimized on CEUS during the surgery. Based on the parameter of time intensity curve and appearances of the lesions on CEUS, the severity of lesions was reclassified and surgical intervention was redesigned in 21 (21/32, 66%) cases. CONCLUSION: Intraoperative CEUS improves accuracy in classification of traumatic brain injury, which helps neurosurgeons to effectively remove hematoma, preserve normal brain tissue, and prevent damaging the vessels during surgical intervention.


Assuntos
Lesões Encefálicas/diagnóstico por imagem , Lesões Encefálicas/cirurgia , Meios de Contraste , Ultrassonografia de Intervenção/métodos , Adulto , Lesões Encefálicas/classificação , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
Zhonghua Yi Xue Za Zhi ; 92(21): 1495-7, 2012 Jun 05.
Artigo em Chinês | MEDLINE | ID: mdl-22944038

RESUMO

OBJECTIVE: To explore the feasibility and value of intra-operative contrast-enhanced ultrasound in different pathological grades of glioma. METHODS: A total of 46 patients with glioma were selected to undergo the contrast-enhanced ultrasound. They were divided into 3 groups according to their pathological grades. RESULTS: All 46 tumors were hyperechoic after examinations and the borders became much more distinct. Different level of tumors had their representative ultrasonic findings. CONCLUSIONS: Intraoperative contrast-enhanced ultrasound is quite useful for determining the position and border of tumors. And it is also excellent in detecting the residual tumor tissues post-operatively. And it can improve the resection accuracy and operative precision, especially for Grade IV glioma with internal necrosis, cyst and surrounding brain edema.


Assuntos
Glioma/diagnóstico por imagem , Monitorização Intraoperatória , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Glioma/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...