Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World J Clin Cases ; 10(25): 9012-9019, 2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36157676

RESUMO

BACKGROUND: Pancreatic metastases account for only a small proportion of all pancreatic malignancies. Isolated pancreatic metastasis from renal cell cancer (isPM-RCC) is extremely rare and may be difficult to differentiate from more common primary neoplasms. A history of nephrectomy is crucial for the diagnosis. CASE SUMMARY: We report the case of a 64-year-old Asian man who was diagnosed with a mass in the pancreatic head using computed tomography. He had no related symptoms, and his medical history was unremarkable, except for unilateral nephrectomy performed to remove a "benign" tumor 19 years ago. All preoperative imaging findings suggested a diagnosis of pancreatic neuroendocrine tumor. However, ultrasound-guided biopsy revealed features of clear cell renal cell carcinoma (ccRCC). Re-examination of the specimen resected 19 years ago confirmed that he had a ccRCC. The pancreatic mass was resected and pathological examination confirmed isPM-RCC. CONCLUSION: Misdiagnosis of isPM-RCC is common because of its rarity and the long interval from resection of the primary tumor and manifestation of the metastasis. The history of the previous surgery may be the only clue.

2.
Medicine (Baltimore) ; 98(28): e16056, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31305391

RESUMO

RATIONALE: Giant uterine myomas may be life-threatening due to pressure effects on the lungs and other contiguous organs. PATIENT CONCERNS: A 32-year-old pregnant Asian woman was admitted to our hospital early in her pregnancy with a pre-pregnancy history of multiple uterine myomas. DIAGNOSIS: She was diagnosed with multiple giant uterine myomas in pregnancy. INTERVENTIONS: No intervention was performed on the woman. OUTCOMES: A reduction in tumor size and disappearance of tumor blood supply were seen on conventional and contrast-enhanced ultrasounds (CEUS) on postpartum day 34. Mass volume gradually decreased and no blood flow signals were seen on CEUS during postpartum follow-up. LESSONS: Childbirth can block the blood supply of giant uterine myomas and reduce mass size. In such cases, childbirth may be considered therapeutic.


Assuntos
Mioma/irrigação sanguínea , Parto/fisiologia , Complicações Neoplásicas na Gravidez/fisiopatologia , Neoplasias Uterinas/irrigação sanguínea , Adulto , Feminino , Humanos , Mioma/complicações , Mioma/diagnóstico por imagem , Gravidez , Carga Tumoral , Neoplasias Uterinas/complicações , Neoplasias Uterinas/diagnóstico por imagem
3.
Ultrasound Med Biol ; 45(3): 732-740, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30558830

RESUMO

Chronic fluid over-hydration is common in dialysis patients. It is associated with mortality and cardiovascular events. Optimal methods for adjusting fluid volume status and ideal dry weight remain uncertain. The purpose of this study was to evaluate the usefulness of ultrasound in quantifying body water. In 35 hemodialysis patients, we performed ultrasound of the chest, pre-tibial skin tissue thickness (TT), heart and inferior vena cava (IVC) before and after dialysis. We compared B-line scores of lungs, IVC diameters and cardiac functions in pre-dialysis and post-dialysis groups. We then estimated the correlations between ultrasound parameters and ultrafiltration volumes. Ultrafiltration parameters were adjusted prospectively for subsequent dialysis. As a result, both extravascular and intravascular water decreased during ultrafiltration. The median numbers of B-line scores (10 [0-42] vs. 4 [0-30]; p < 0.001); mitral valve blood flow velocities E (0.83 ± 0.23 m/s vs. 0.70 ± 0.20 m/s; p < 0.001), A (0.93 ± 0.28 vs. 0.89 ± 0.23 m/s; p < 0.001) and E/e' (12.47 ± 4.92 vs. 10.37 ± 4.0; p < 0.001); IVC diameters at end-expiration (17.51 ± 3.33 mm vs. 14.26 ± 3.45 mm; p < 0.001); and right pre-tibial TT (2.86 ± 1.36 mm vs. 2.43 ± 1.24 mm; p < 0.001) decreased during dialysis. Ultrafiltration volume was most associated with B-line score (adjusting for age and sex) (ß = -3.340; p = 0.003). In addition, the B-line score after dialysis was significantly associated with left ventricular ejection fraction (r = -0.393; p = 0.019) and TT (r = -0.447; p = 0.007). Ultrafiltration volume was prospectively increased then if the B-line score was >6 in the previous dialysis. All patients tolerated the protocol well without any symptoms. Ultrafiltration volume was most associated with lung water, reflected by variation in B-line score. It was not associated with cardiac function, IVC diameter, IVC collapse rate or TT. Lung ultrasound is a useful imaging tool for dialysis patients.


Assuntos
Água Corporal/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Diálise Renal , Ultrassonografia/métodos , Equilíbrio Hidroeletrolítico/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrafiltração
4.
Ultraschall Med ; 39(5): 526-534, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30176697

RESUMO

BACKGROUND: Breast lesions classified as BI-RADS-US 3 are probably benign and observation was recommended, while a considerable number of BI-RADS-US 4 lesions were benign, resulting in excessive biopsies. We focus exclusively on BI-RADS-US 3 and 4 lesions and hypothesize that improved diagnostic performance can be achieved by integrating real-time elastography (strain ratio) into the BI-RADS-US classification system. METHOD: From April 2010 to September 2015, 1071 lesions were included in the final analysis. After the conventional ultrasound examination, the BI-RADS-US (2013) classification was used to evaluate the lesions. Then the strain ratios were calculated, and the final diagnosis was made on the basis of histological results. The sensitivity, specificity, accuracy, PPV and NPV were calculated and the AUCs were compared. Additionally, an analysis of the diagnostic performance expressed by the pretest and posttest probability of disease (POD) was performed in BI-RADS-US 3 and 4A lesions. RESULTS: With the cutoff point of 2.98, the sensitivity, specificity and accuracy of the strain ratio method were 86.9 %, 86.6 % and 82.6 %, respectively. In BI-RADS-US 3 lesions, a suspicious strain ratio significantly modified the POD from 1.3 % to a posttest POD of 29.8 %. In BI-RADS-US 4A lesions, a suspicious strain ratio significantly modified the POD from 8.5 % to a posttest POD of 48.7 %. CONCLUSION: Ultrasonographic elastography (strain ratio) yields additional diagnostic information in the evaluation of BI-RADS-US 3 and 4 breast lesions. The strain ratios should be integrated into the BI-RADS-US classification system and into daily practice.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Sensibilidade e Especificidade , Ultrassonografia Mamária
5.
Ultrasound Med Biol ; 43(5): 903-910, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28256344

RESUMO

On the basis of results of our previous studies and the findings of other scholars, the most common histologic type of false-positive diagnosis with strain elastography (SE) was papilloma. The objectives of our study were to evaluate whether SE could contribute to conventional ultrasound differentiation between benign and malignant papillary lesions and between papillary lesions and other common benign breast lesions. Data on 89 papillary lesions at our hospital, including 74 benign and 15 malignant papillary lesions, were included in our study. In addition, 198 non-papillary benign tumors were selected as the control group, including 126 fibroadenomas and 72 cases of fibrocystic mastopathy. All patients gave written informed consent. All patients with breast lesions underwent conventional ultrasound and SE examination. Breast Imaging Recording and Data System (BI-RADS) category and SE score were compared with respect to sensitivity, specificity and accuracy in differentiating between benign and malignant papillary lesions. We then explored the possibility of using BI-RADS combined with SE to differentiate papillary lesions from non-papillary benign tumors. For differentiating between benign and malignant papillary lesions, the area under the receiver operating characteristic curve (AUC) of BI-RADS was 0.568, whereas the AUC values of SE score, strain ratio and BI-RADS combined with SE were 0.517, 0.584 and 0.509, respectively (p > 0.05). For differentiating between papillary lesions and non-papillary benign lesions, the AUC of BI-RADS combined with SE was 0.835, which was higher than the values for BI-RADS (0.775) and SE (SE score: 0.648, strain ratio: 0.661) (p < 0.001). The specificity and accuracy of BI-RADS combined with SE were significantly higher than those for BI-RADS alone without a decrease in sensitivity (p < 0.05). SE could not improve the diagnostic efficiency of BI-RADS in differentiating between benign and malignant papillary lesions. However, BI-RADS combined with SE could improve the specificity of BI-RADS without decrease in sensitivity for differentiating breast papillary lesions from non-papillary benign lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Papiloma/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
6.
PLoS One ; 11(2): e0148330, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26863208

RESUMO

BACKGROUND: This study aimed to confirm whether strain ratio should be added after evaluation of lesions with 5-point elasticity scoring for differentiating benign and malignant breast lesions on ultrasonographic elastography(UE). MATERIALS AND METHODS: From June 2010 to March 2012, 1080 consecutive female patients with breast lesions were recruited into a multicenter retrospective study, which involved 8 centers across China. Each institutional ethic review board approved the study, and all the patients gave written informed consent. All the patients underwent the UE procedure and the strain ratios were calculated and the final diagnosis was made by histological findings. The sensitivity, specificity, accuracy, PPV and NPV were calculated for each of the two evaluation systems and the areas under the ROC curve were compared. RESULTS: The strain ratios of benign lesions (mean, 2.6±2.0) and malignant lesions (mean,7.9±5.8) were significantly different (p <0.01). When the cutoff point was 3.01, strain ratio method had 79.8% sensitivity, 82.8% specificity, and 81.3% accuracy, while the 5-point scoring method had 93.1% sensitivity, 73.0% specificity, and 76.8% accuracy. The areas under the ROC curve with the strain ratio method and 5-point scoring method were 0.863 and 0.865, respectively(p>0.05). The strain ratio method shows better a diagnosis performance of the lesions with elasticity score 3 and 4. CONCLUSIONS: Although the two UE methods have similar diagnostic performance, separate calculation of the strain ratios seems compulsory, especially for the large solid breast lesions and the lesions with elasticity score 3 and 4.


Assuntos
Adenocarcinoma/diagnóstico , Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adenocarcinoma/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Elasticidade , Técnicas de Imagem por Elasticidade/instrumentação , Feminino , Humanos , Glândulas Mamárias Humanas/patologia , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Ultrassonografia Mamária/instrumentação
7.
Clin Breast Cancer ; 16(3): e33-41, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26639065

RESUMO

PURPOSE: To evaluate the additive diagnostic performance of ultrasound elastography (UE) to ultrasound (US) with the 2003 or 2013 Breast Imaging Reporting and Data System (BI-RADS)-US classification systems for the differentiation of benign and malignant breast lesions. METHODS: From June 2010 to December 2012, 738 women with 770 breast lesions were recruited into this retrospective study. Breast lesions were evaluated separately by US, UE, and both. US assessment was based on the 2003 or 2013 BI-RADS-US, and UE assessment was based on a previously reported 5-point scale. Diagnostic performance of US, UE, and both was compared. RESULTS: Before category 4 lesions were subdivided, the area under the receiver operating characteristic curve (AUC) for US, UE, and both were, respectively, 0.735, 0.877, 0.878 (P < .01). When subcategories of 4 lesions were considered, the AUC for US, UE, and both were, respectively, 0.865, 0.877, and 0.883 (P > .05). Adding UE to analysis of 4A lesions can decrease the percentages of malignancy to 2.56%. CONCLUSION: When the 2003 BI-RADS was considered, UE could give US some help in differentiating breast lesions. However, when the 2013 BI-RADS was considered, UE gave little help to US, although it reduced unnecessary biopsies of benign category 4A lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
8.
Eur J Radiol ; 84(12): 2492-500, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26349410

RESUMO

OBJECTIVES: The purpose was to evaluate whether BI-RADS (the Breast Imaging Recording and Data System) combined with UE (ultrasound elastography) could improve the differentiation and characterization of benign and malignant breast lesions by comparing with BI-RADS. METHODS: A total of 1080 patients with 1194 breast lesions were studied retrospectively at 8 different institutions from 3 geographic areas across China (North, South, and West) from June 2010 to March 2012. Each institutional ethic review board approved the study and all patients gave written informed consent. All the cases were examined by conventional US (ultrasonography) and UE prior to ultrasound-guided core biopsy. Performance of BI-RADS and BI-RADS combined with UE were compared in different size groups, age groups and area groups. RESULTS: BI-RADS combined with UE cloud improve the accuracy by 13.2% compared to BI-RADS alone for all lesions, 23.2% for <10 mm lesions, 13.3% for ≥10-20 mm lesions, 6.3% for ≥20 mm lesions, 18.4% for <50 years group, 1.7% for ≥50 years group, 13.7% for northern area group, 17.7% for southern area group and 4.4% for western area group. CONCLUSIONS: The help which UE contributed to BI-RADS was greater for breast lesions <10mm and <50 years group.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Sistemas de Informação em Radiologia , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , China , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
9.
Zhonghua Nan Ke Xue ; 21(6): 536-40, 2015 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-26242045

RESUMO

OBJECTIVE: To investigate the association between the level of serum testosterone and atherosclerosis in middle-aged and elderly men. METHODS: We conducted a population-based study of 413 males aged 40-75 years in a community in Guangzhou. We obtained the sociodemographic characteristics, clinical data, physical measurements, and laboratory results of sex hormones, blood glucose, and blood lipid of the subjects. We also measured the carotid intima media thickness (CIMT) by color Doppler ultrasonography. RESULTS: The subjects were divided into a carotid atherosclerosis (CAS) group (CIMT ≥ 0.9 mm) and a non-CAS group (CIMT < 0.9 mm). The medians of free testosterone (FT) were 57.41 and 59.72 pmol/L in the CAS and non-CAS groups, respectively (P = 0.005), and no significant difference was found between the two groups in total testosterone (TT). The levels of serum FT and TT were negatively correlated to CIMT, with Spearman's rank correlation coefficients of -0.126 (P = 0.011) and -0.188 (P < 0.001), respectively. The incidence rates of CAS were 23.30, 13.46, 17.48, and 7.77% in the Q1, Q2, Q3, and Q4 groups, respectively according to the quartile of FT (P for trend = 0.008) and 17.48, 18.27, 16.50, and 9.71% respectively according to the quartile of TT (P for trend = 0.116). Based on the quartile of FT and after adjustment for age, waist circumference, systolic blood pressure, and HbAlc, the risk of CAS was significantly increased in the Q1 group as compared with Q4 (OR = 2.491, 95% CI 1.01-6.149), but no statistically significant differences were observed according to the quartile of TT. CONCLUSION: A low serum FT level may be a risk factor of atherosclerosis in Chinese men aged 40 years or older.


Assuntos
Doenças das Artérias Carótidas/sangue , Espessura Intima-Media Carotídea , Testosterona/sangue , Adulto , Fatores Etários , Idoso , Glicemia/análise , Pressão Sanguínea , Doenças das Artérias Carótidas/epidemiologia , Doenças das Artérias Carótidas/etiologia , Hormônios Esteroides Gonadais/sangue , Humanos , Incidência , Lipídeos/sangue , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Estatísticas não Paramétricas
10.
PLoS One ; 9(1): e85257, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24454830

RESUMO

The purpose of this study was to analyze the ultrasonic elastography features of phyllodes tumors of the breast comparing with fibroadenomas. A retrospective database was queried for the patients diagnosed as phyllodes tumors and fibroadenomas at Sun Yat-sen Memorial Hospital from January 2008 to August 2012. Three hundred and fifty lesions from 323 consecutive patients were included in the study. All the cases were examined by conventional ultrasonography and ultrasound elastography. Ultrasound elastography was used to calculate strain ratio of the lesions with bilateral breast tissue at the same depth as reference. There were 36 phyllodes tumors (27 benign, 8 borderline, 1 malignant) and 314 fibroadenomas (158 the pericanalicular type, 103 the intracanalicular type, 53 other special types). The strain ratio for phyllodes tumors (3.19 ± 2.33) was significantly higher than for fibroadenomas (1.69 ± 0.88) (p<0.05). The Spearman(.)s correlation coefficient between strain ratio of ultrasound elastography and pathological groups was significant, with a value of 0.17 (p<0.05). Ultrasound elastography could provide additional information to differentiate phyllodes tumors from fibroadenoma in breast.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Tumor Filoide/diagnóstico por imagem , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...