Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhongguo Gu Shang ; 35(11): 1074-80, 2022 Nov 25.
Artigo em Chinês | MEDLINE | ID: mdl-36415195

RESUMO

OBJECTIVE: To explore the early clinical efficacy of primary total hip arthroplasty(THA) with Corail standard stems (KS type) and high offset stems (KHO type), by analyzing the postoperative radiographic parameters of different offset of femoral components with Corail stem which has a neck-shaft angle of 135 ° in unilateral primary THA, by comparing the measurement results on both sides and analyzing the reconstruction of the postoperative femoral offset and the hip joint function recovery. METHODS: A retrospective analysis was made of 186 patients with unilateral hip joint lesions who underwent the first total hip arthroplasty with Johnson & Johnson Corail prostheses from January 2015 to June 2017. According to the use of femoral prostheses with different eccentricities during the operation, the patients were divided into high eccentricity group and standard eccentricity group. In the high eccentricity group, there were 52 cases of Corail high eccentricity prosthesis(KHO type), including 20 females and 32 males;aged 21 to 71 years old with an average of(50.6±13.2) years;body mass index(BMI) was (26.0±4.1) kg/m2. The standard eccentricity group included 134 Corail standard femoral stem prostheses(KS type), 57 females and 77 males;aged 18 to 77 years old with an average of (47.3±14.0) years;BMI was (25.3±3.5) kg/m2. The abduction arm, femoral eccentricity, acetabular eccentricity and the length difference of lower limbs were measured on the postoperatively positive X-ray film of the hip joint. Harris score and related complications were recorded before and after the operation, and the stability of the prosthesis was analyzed. RESULTS: There were significant differences in femoral eccentricity, joint eccentricity and abduction arm between the affected side and the healthy side in the high eccentricity group(P<0.05). There were significant differences in femoral eccentricity and acetabular eccentricity between the affected side and the healthy side in the standard eccentricity group(P<0.05). There were significant differences in combined eccentricity, abduction arm and length of lower limbs between two groups(P<0.05). In the high eccentricity group, the abduction arm of the affected hip joint was positively correlated with the femoral eccentricity, acetabular eccentricity and joint eccentricity(r=0.633, P<0.001;r=0.384, P=0.005;r=0.690, P<0.001). The same results were also obtained in the healthy side(r=0.688, P<0.001;r=0.574, P<0.001;r=0.765, P<0.001). In the standard eccentricity group, the abduction arm of the affected hip joint was positively correlated with the femoral eccentricity, acetabular eccentricity and combined eccentricity(r=0.734, P<0.001;r=0.418, P<0.001;r=0.749, P<0.001). The same results were also obtained in the healthy side(r=0.775, P<0.001;r=0.397, P<0.001;r=0.773, P<0.001). The difference of the length of both lower limbs was significantly correlated with the difference of bilateral joint eccentricity and bilateral abduction arm (r=0.376, P=0.006;r=-0.346, P=0.012). There was no significant correlation between the difference of the length of both lower limbs and the difference of bilateral joint eccentricity and bilateral abduction arm (r=-0.009, P=0.919;r=-0.036, P=0.682). There was no significant difference in Harris score between two groups at the last follow-up(P>0.05). At the last follow-up, Trendelenburg was negative in all patients in both groups, and the prostheses were stable. CONCLUSION: Both Corail standard stem and high offset stem may be effectively reconstruct the femoral offset, reconstruct the anatomical structure and biomechanics of the hip joint, and maintain the length of lower limbs and the stability of the hip joint in the unilateral primary total hip arthroplasty. Although the offset of the femur was not reconstructed normally in some cases, the stability of the components and postoperative function were not affected.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Adolescente , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Fêmur/cirurgia , Extremidade Inferior
2.
World J Clin Cases ; 10(31): 11349-11357, 2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36387798

RESUMO

BACKGROUND: Patellar tendon rupture after total knee arthroplasty (TKA) is a catastrophic complication. Although the occurrence of this injury is rare, it can lead to significant dysfunction for the patient and is very tricky to deal with. There has been no standard treatment for early patella tendon rupture after TKA, and long-term follow-up data are lacking. AIM: To introduce a direct repair method for early patella tendon rupture following TKA and determine the clinical outcomes and complications of this method. METHODS: During the period of 2008 to 2021, 3265 consecutive TKAs were retrospectively reviewed. Twelve patients developed early patellar tendon rupture postoperatively and were treated by a direct repair method. Mean follow-up was 5.7 years. Demographic, operative, and clinical data were collected. The clinical outcomes were assessed using the Western Ontario and McMaster Universities (WOMAC) score, the Hospital for Special Surgery (HSS) score, knee range of motion, extensor lag, and surgical complications. Descriptive statistics and paired t test were employed to analyze the data. RESULTS: For all 12 patients who underwent direct repair for early patellar tendon rupture, 3 patients failed: One (8.3%) for infection and two (17.6%) for re-fracture. The two patients with re-fracture both underwent reoperation to reconstruct the extensor mechanism and the patient with infection underwent revision surgery. The range of motion was 109.2° ± 10.6° preoperatively to 87.9° ± 11° postoperatively, mean extensor lag was 21° at follow-up, and mean WOMAC and HSS scores were 65.8 ± 30.9 and 60.3 ± 21.7 points, respectively. CONCLUSION: This direct repair method of early patellar tendon rupture is not an ideal therapy. It is actually ineffective for the recovery of knee joint function in patients, and is still associated with severe knee extension lag and high complication rates. Compared with the outcomes of other repair methods mentioned in the literature, this direct repair method shows poor clinical outcomes.

3.
World J Clin Cases ; 10(23): 8107-8114, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-36159530

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) has been shown to improve quality of life and reduce pain. High-flexion activities such as squatting, kneeling, and floor transfers are mainly listed as demanding tasks. Among them, squatting is an important position. AIM: To provide a new squat position classification and evaluate the different squatting positions of a series of patients after primary TKA. METHODS: From May 2018 to October 2019, we retrospectively reviewed 154 video recordings of the squatting-related motions of patients after TKA. Among the included patients, 119 were women and 35 were men. Their mean age at the index surgery was 61.4 years (range, 30 to 77). RESULTS: The median follow-up was 12 mo (range, 6 to 156 mo). We classified those squatting-related motions into three major variations according to squatting depth: Half squat, parallel squat, and deep squat. The angles of hip flexion, knee flexion, and ankle dorsiflexion were measured in the screenshots captured from the videos at the moment of squatting nadir. A total of 26 patients were classified as half squats, 75 as parallel squats, and 53 as deep squats. The angles of hip flexion, knee flexion, and ankle dorsiflexion all differed significantly among the three squatting positions (P < 0.001). In the parallel squat group, the mean knee flexion angle (°) was 116.5 (SD, 8.1; range, 97 to 137). In the deep squat group, the mean knee flexion angle (°) was 132.5 (SD, 9.3; range, 116 to 158). CONCLUSION: Among the three squatting positions, deep squat showed the highest hip, knee, and ankle flexion angles, followed by the parallel squat. With the improvement of squatting ability, the patient's postoperative satisfaction rate was also significantly enhanced. However, the different squatting abilities of the patients cannot be effectively distinguished from the scoring results (P > 0.05). Our squatting position classification offers a pragmatic approach to evaluating patients' squatting ability after TKA.

4.
Zhongguo Gu Shang ; 35(7): 610-4, 2022 Jul 25.
Artigo em Chinês | MEDLINE | ID: mdl-35859368

RESUMO

OBJECTIVE: To investigate the application of high offset femoral stem prosthesis in primary total hip arthroplasty. METHODS: From January 2015 to June 2017, 51 patients with unilateral hip diseases who underwent primary total hip arthroplasty with Corail high offset femoral stem prosthesis(KHO type) were selected for retrospective study, including 20 females and 31 males;the age ranged from 21 to 71 years old with an average of(50.8±13.3) years old. The abduction arm, femoral offset, acetabular offset and the length of lower limbs were measured on the positive X-ray film of hip joint after operation. Harris scores before and after operation and related complications were recorded, and the stability of prosthesis was analyzed. RESULTS: The femoral offset, combined offset and abduction arm of the affected side were significantly greater than those of the healthy side(P<0.05). There was no significant difference in acetabular offset between the affected side and the healthy side (P>0.05). The femoral offset of 17 hips (33.3%) was reconstructed normally, of which 15 cases (88.2%) had equal length of both lower limbs. The femoral offset of 34 hips (66.7%) was greater than that of the healthy side, and 34 cases (100%) had equal length of both lower limbs. All 51 patients were followed up for(42.3±7.3) months. The Harris score increased from 38.0±7.6 before operation to 92.1±3.1 at the final follow-up(P<0.001). CONCLUSION: Although the high offset Corail prosthesis can not normally reconstruct the femoral offset in unilateral primary total hip arthroplasty, it does not affect the reconstruction of the length of lower limbs and the stability of the prosthesis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Adulto , Idoso , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
5.
J Orthop Surg Res ; 16(1): 149, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33610184

RESUMO

BACKGROUND: Knee osteoarthritis associated with extra-articular deformity (EAD) can confront the arthroplasty surgeons with challenges of bone resection and soft tissue balancing. The aim of this study was to describe a single-stage procedure associating corrective osteotomy with total knee arthroplasty (TKA), and to determine the outcome at mid- to long-term follow-up. METHODS: A total of seven patients (seven knees) with knee osteoarthritis and supracondylar deformity were included in this study. Six patients were female, and one was male, with the median age of 62 years (range, 37-76 years). All patients were treated with single-stage TKA and femoral osteotomy. Osteotomy was fixed with long cemented stem. Hospital of Special Surgery (HSS) scores, collateral ligament laxity, and range of motion (ROM) were clinically evaluated preoperatively and at each follow-up. Radiographic parameters including the mechanical axis deviation (MAD), mechanical lateral distal femoral angle (mLDFA), mechanical proximal tibial angle (mMPTA), and joint line congruence angle (JLCA) were also measured. The occurrence of perioperative complications was recorded. RESULTS: The median follow-up time was 91 months (range, 38-104 months). At the last follow-up, all components were stable and no patients required revision. Nonunion of the osteotomy occurred in one patient. In all patients, the lower limb mechanical alignment improved greatly. The mean angle of MAD was restored from 10.49±6.05 cm preoperatively to 1.11±4.97 cm postoperatively. The 90° mLDFA was almost acquired in all cases, with the postoperative value of 90.79±2.40°. After operation, the mMPTA improved from 84.18±6.13° to 91.33±3.13°. The JLCA changed from 2.94±1.61° to -0.71±3.50°. The median HSS score improved from 45 (range, 34-56) preoperatively to 90 (range, 82-97) postoperatively, with the outcome of all patients rated good to excellent. The median ROM improved from 70° (range 0-110°) preoperatively to 105° (range 90-125°) postoperatively. No instability of knee joint was observed. Complications included an intraoperative split fracture of distal femur and one case of wound exudation resulting from fat liquefaction. CONCLUSIONS: For knee osteoarthritis with femoral supracondylar deformity, single-stage TKA and corrective osteotomy was feasible but technically demanding. The use of long cemented stem for osteotomy fixation can provide reliable rotational control of the bone segments.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Deformidades Articulares Adquiridas/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Med Sci Monit ; 26: e926239, 2020 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-33099571

RESUMO

BACKGROUND Indications for subtrochanteric shortening osteotomy (SSOT) during Crowe type IV developmental dysplasia of the hip (DDH) are unclear. The aim of this retrospective study was to create a model to predict the need for performing SSOT. MATERIAL AND METHODS One hundred forty-nine patients (186 hips) with Crowe Type IV DDH who underwent total hip arthroplasty (THA) with S-ROM implants from January 2010 to November 2018 were included in the study. The acetabular components were placed at the true acetabulum and the trial femoral component was inserted. Reduction then was attempted and if it could not be achieved, SSOT was performed. Using multivariable Cox regression analysis, a model was constructed that included age, sex, surgical history, use of a cone- or triangle-shaped sleeve, secondary acetabulum formation, and percentage of dislocation as predictive factors for SSOT. RESULTS SSOTs were performed on 140 of 186 hips. Secondary acetabulum formation was present in 27 hips (58.70%) in which SSOT was not performed 7 (5.00%) in which it was performed. Cone-shaped sleeves were used in 17 hips (36.96%) in which SSOT was not performed versus 15 (10.71%) hips in which it was performed. Dislocation occurred in 31.30±5.80% hips in which SSOT was performed versus 24.05±4.39% of those in which it was not performed. Percentage of dislocation was associated with an increased likelihood of SSOT (odds ratio [OR] 1.24, 95% confidence interval 1.11-1.38), whereas secondary acetabulum formation (OR 0.10, 0.03-0.33) and use of a cone-shaped sleeve (0.18, 0.06-0.53) were associated with decreased likelihood of SSOT. We established a model for prediction of SSOT with a nanogram and the discriminative ability (C statistic) of it was 0.918 (0.79-0.92). CONCLUSIONS Factors that significantly affect likelihood of performing an SSOT were identified and a model with significant ability to predict the need for SSOT in patients with Crowe Type IV DDH was created.


Assuntos
Artroplastia de Quadril/efeitos adversos , Displasia do Desenvolvimento do Quadril/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...