Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
J Clin Ultrasound ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581196

RESUMO

OBJECTIVE: The aim of this study was to investigate the value of Broncoplasma Insufflation Sign in lung ultrasound signs in assessing the efficacy of bronchoalveolar lavage in Severe mycoplasma pneumoniae pneumonia in children. METHODS: Forty-seven children with Severe mycoplasma pneumoniae pneumonia were treated with medication and bronchial lavage. Laboratory and imaging results were collected, and lung ultrasonography was performed before bronchoalveolar lavage and 1, 3, and 7 days after lavage to record changes in Bronchial Insufflation Sign and changes in the extent of solid lung lesions. Factors affecting the effectiveness of bronchoalveolar lavage were analyzed using logistic regression and other factors. RESULTS: Bronchial Insufflation Sign Score and the extent of lung solid lesions were the factors affecting the effectiveness of bronchoalveolar lavage treatment. The smaller the area of lung solid lesions and the higher the Bronchial Insufflation Sign Score, the more effective the results of bronchoalveolar lavage treatment were, and the difference was statistically significant, with a difference of p < 0.05. The Bronchial Insufflation Sign Score had the highest sensitivity and specificity for the prediction of the efficacy of bronchoalveolar lavage treatment in the first 7 days after the treatment. CONCLUSION: Bronchial Insufflation Sign Score combined with the extent of solid lung lesions can assess the efficacy of bronchoalveolar lavage in the treatment of Severe mycoplasma pneumoniae pneumonia in children; lung ultrasound is a timely and effective means of assessing the efficacy of bronchoalveolar lavage.

2.
Eur Rev Med Pharmacol Sci ; 27(21): 10419-10426, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37975365

RESUMO

OBJECTIVE: The purpose of this research was to investigate whether it is possible to perform ultra-early interventional electroacupuncture on individuals who had experienced intravenous thrombolysis prior to receiving therapy for acute cerebral infarction. PATIENTS AND METHODS: Patients who have undergone intravenous thrombolysis between July 2019 and March 2021 were eligible for participation in this study. The participants were divided into two groups; one group received electroacupuncture therapy 24 hours after their condition became stable, while the other group received treatment 48 hours after their condition became stable. Both groups received the same therapy for their respective forms of rehabilitation. The Fugl-Meyer Motion Assessment Scale (FMA) was used to assess the patients' motor function before and after therapy, as well as two weeks and one month after treatment. The scores of the FMA were recorded before and after treatment. RESULTS: After therapy, the FMI scores were higher in both groups (p<0.05), and the researchers found that the ultra-early electroacupuncture intervention was related to higher FMI ratings 2 weeks and 1 month after treatment (p<0.05). In neither of the two study groups was there any sign of a major adverse response or consequence (p>0.05). CONCLUSIONS: This research offers evidence that ultra-early interventional electroacupuncture rehabilitation therapy may be an effective and safe method of treatment for individuals who have had a cerebral infarction after receiving intravenous thrombolysis. The results lend credence to the notion that this kind of therapy should be taken into consideration as an adjunctive model for rehabilitation in patients of this type.


Assuntos
Isquemia Encefálica , Eletroacupuntura , Acidente Vascular Cerebral , Humanos , Eletroacupuntura/métodos , Infarto Cerebral/terapia , Acidente Vascular Cerebral/terapia , Terapia Trombolítica , Resultado do Tratamento
4.
Artigo em Chinês | MEDLINE | ID: mdl-31623045

RESUMO

Objective:The aim of this study is to investigate the method and effect of reconstruction of facial skin defects after removing the lesions by applying local flap. Method:Fifty-three patients (30 males and 23 females) with facial skin lesions. Complete surgical resection of the lesion; malignant tumor resection should be strictly non-tumor principle; intraoperative frozen section pathological examination confirmed negative margin; benign lesions can be cut off the lesion. According to the defect site, the appropriate local flap was used to repair the defect: 13 cases of modified VY propulsion flap, 8 cases of nasolabial flap, 8 cases of A/O-T shaped flap, 6 cases of rotating flap, 5 cases of direct sliding flap, multi-type There were 6 cases with flap, 2 cases with double leaf, 2 cases with prismatic flap and 3 cases with free flap. Result:Patients with malignant tumor were followed for 12-36 months postoperatively while followed for 10-12 months in the benign. Two patients with malignant tumor developed local recurrence and removed again. At half a year after first resection. Distal partial necrosis occurred in 5 cases while the wound dehiscence in1case, others were well developed. No others major complications occurred. Conclusion:There are various types of local skin flap for repairing facial skin defects. It is very important to excise the primary lesion radically before reconstruction,the satisfactory curative effect can be obtained through reasonable design of the flap.


Assuntos
Procedimentos de Cirurgia Plástica , Transplante de Pele , Face , Feminino , Humanos , Masculino , Pele , Retalhos Cirúrgicos , Resultado do Tratamento
5.
Cureus ; 11(4): e4510, 2019 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-31259119

RESUMO

"Delta-radiomics" investigates variations in quantitative image metrics over time and can yield important clinical information. We hypothesized that in patients undergoing active radiation therapy (RT) for prostate cancer (PCa), there would exist observable variation in the quantitative metrics that describe the T2-weighted (T2W) intensity histogram in the prostate and surrounding organs at risk (OAR) over time. We investigated the feasibility of acquisition and subsequent analysis of the delta-radiomic profiles of these regions of interest (ROI) in serial T2W magnetic resonance (MR) images obtained on a 1.5 Tesla (T) Magnetic Resonance Linear Accelerator (MRL). Principally, we sought to illustrate the significance of longitudinal radiomic data acquisition for tissue response monitoring and provide a framework for future hypothesis driven research. Patients with PCa undergoing treatment with RT were compiled from an ongoing prospective observational imaging trial using a 1.5 T MRL (NCT30500081). Contiguous axial slices of prostate parenchyma were contoured and temporally normalized to sections of Sartorius muscle which served as a control. Similarly, contiguous sections of rectal and bladder wall adjacent to the prostate were contoured and temporally normalized to regions of these organs further removed from the planning target volume (PTV). First order statistical descriptors of the T2W intensity histogram were extracted and evaluated for changes over time using linear mixed effects regression modeling and post-hoc contrasts. Benjamini-Hochberg corrections were employed to reduce the effects of multiple testing and control for the false discovery rate (FDR). Four patients with a median age of 69 comprised this exploratory cohort. One patient had low-risk disease, two had intermediate (one favorable, one unfavorable), and one had high risk disease. Three out of four patients underwent definitive radiation to 75.6 Gray (Gy) in 42 fractions and one received hypofractionated therapy to a total dose of 70 Gy over 28 fractions, and all received treatment on a conventional linear accelerator. The most significant acute toxicity event was grade 2 GU dysfunction observed in two patients. Follow up ranged from 1 month to 10 months post treatment, and no long-term complications were reported in patients who completed treatment at least one month prior. Bladder wall adjacent to the prostate demonstrated significant variation in the mean and median metric values after the first week of treatment. In addition, rectal wall adjacent to the prostate exhibited significant variation in the mean, median, and standard deviation metric values by the second week of treatment. No significant variation in any radiomic feature was observed in the Sartorius control. This exploratory study is one of the earliest examining the delta-radiomic characteristics of the T2W intensity histogram in OAR extracted from images acquired on a 1.5 T MRL in patients actively being treated with RT for PCa. We demonstrated a feasible approach to longitudinal radiomic data acquisition providing limitless opportunity for future research. Analysis of the delta-radiomic profiles in OAR revealed significant variation in metrics after only one week of RT in bladder and rectal wall adjacent to the prostate. These findings must be further investigated and validated with expanded data sets with long-term follow up and correlation to clinical outcomes including toxicity and tumor control.

6.
Eur Rev Med Pharmacol Sci ; 23(7): 2710-2718, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31002120

RESUMO

OBJECTIVE: The aim of this study was to investigate the expression level of micro-ribonucleic acid-1207-5p (miR-1207-5p) in steroid-induced necrosis of femoral head (SNFH) and its correlation with SNFH. Meanwhile, we also aimed to analyze the relationship between miR-1207-5p expression and vascular endothelial growth factor (VEGF) in the femoral head. PATIENTS AND METHODS: From May 2016 to December 2017, 60 patients aged (55.4±8.7) were selected in our hospital. All patients were diagnosed and confirmed as SNFH. Total RNA was extracted from the necrotic femoral head tissues and peripheral blood. Reverse Transcription-Polymerase Chain Reaction (RT-PCR) was used to detect the expression level of miR-1207-5p in tissues. At the same time, immunohistochemistry and Western blotting were adopted to detect VEGF expression in the bone tissue of patients with high or low expression of miR-1207-5p. 7 patients with femoral neck fracture aged (45.6±4.51) were enrolled in the control group. In the animal experiment, the rat SNFH model was established by intraperitoneal injection of lipopolysaccharide and methylprednisolone. Subsequently, the expression levels of miR-1207-5p and VEGF in necrotic femoral tissues were detected. Meanwhile, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining was applied to detect cell apoptosis in bone lacunae of miR-1207-5p high expression group and miR-1207-5p low expression group, respectively. RESULTS: The expression level of miR-1207-5p in the necrotic bone tissue of the SNFH group was significantly higher than that of the control group. The expression level of miR-1207-5p was inversely proportional to Harris Hip score (p<0.05). A higher expression of miR-1207-5p indicated a lower expression level of VEGF (p<0.05). The animal experimental results revealed that miR-1207-5p expression in the necrotic femoral head tissue of SNFH group was significantly higher than that of the control group. Furthermore, the number of apoptotic cells in bone lacunae was remarkably higher in miR-1207-5p high expression group (p<0.05). CONCLUSIONS: MiR-1207-5p is significantly up-regulated in necrotic femoral head tissue and serum of SNFH patients. Meanwhile, its expression level is inversely proportional to Harris Hip score of patients. The possible underlying mechanism may be related to the inhibitory effect of miR-1207-5p on VEGF.


Assuntos
Necrose da Cabeça do Fêmur/metabolismo , Cabeça do Fêmur/patologia , MicroRNAs/genética , Regulação para Cima , Fator A de Crescimento do Endotélio Vascular/metabolismo , Animais , Apoptose , Estudos de Casos e Controles , Necrose da Cabeça do Fêmur/induzido quimicamente , Humanos , Marcação In Situ das Extremidades Cortadas/métodos , Injeções Intraperitoneais , Lipopolissacarídeos/administração & dosagem , Lipopolissacarídeos/efeitos adversos , Masculino , Metilprednisolona/administração & dosagem , Metilprednisolona/efeitos adversos , Pessoa de Meia-Idade , Modelos Animais , Ratos , Ratos Sprague-Dawley , Esteroides/administração & dosagem , Esteroides/efeitos adversos
7.
Pract Radiat Oncol ; 7(2): 126-136, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28089481

RESUMO

PURPOSE: Local recurrence is a common and morbid event in patients with unresectable pancreatic adenocarcinoma. A more conformal and targeted radiation dose to the macroscopic tumor in nonmetastatic pancreatic cancer is likely to reduce acute toxicity and improve local control. Optimal soft tissue contrast is required to facilitate delineation of a target and creation of a planning target volume with margin reduction and motion management. Magnetic resonance imaging (MRI) offers considerable advantages in optimizing soft tissue delineation and is an ideal modality for imaging and delineating a gross tumor volume (GTV) within the pancreas, particularly as it relates to conformal radiation planning. Currently, no guidelines have been defined for the delineation of pancreatic tumors for radiation therapy treatment planning. Moreover, abdominal MRI sequences are complex and the anatomy relevant to the radiation oncologist can be challenging. The purpose of this study is to provide recommendations for delineation of GTV and organs at risk (OARs) using MRI and incorporating multiple MRI sequences. METHODS AND MATERIALS: Five patients with pancreatic cancer and 1 healthy subject were imaged with MRI scans either on 1.5T or on 3T magnets in 2 separate institutes. The GTV and OARs were contoured for all patients in a consensus meeting. RESULTS: An overview of MRI-based anatomy of the GTV and OARs is provided. Practical contouring instructions for the GTV and the OARs with the aid of MRI were developed and included in these recommendations. In addition, practical suggestions for implementation of MRI in pancreatic radiation treatment planning are provided. CONCLUSIONS: With this report, we attempt to provide recommendations for MRI-based contouring of pancreatic tumors and OARs. This could lead to better uniformity in defining the GTV and OARs for clinical trials and in radiation therapy treatment planning, with the ultimate goal of improving local control while minimizing morbidity.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/radioterapia , Imageamento por Ressonância Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional , Adenocarcinoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias , Órgãos em Risco/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Guias de Prática Clínica como Assunto , Doses de Radiação , Tomografia Computadorizada por Raios X , Carga Tumoral , Adulto Jovem
8.
Med Phys ; 43(8): 4575, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27487874

RESUMO

PURPOSE: In a situation where a couch shift for patient positioning is not preferred or prohibited (e.g., MR-linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening-filter-free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here the authors propose a new two-step process to address both the translational effect of FFF beams and the target deformation. METHODS: The replanning method consists of an offline and an online step. The offline step is to create a series of preshifted-plans (PSPs) obtained by a so-called "warm start" optimization (starting optimization from the original plan, rather than from scratch) at a series of isocenter shifts. The PSPs all have the same number of segments with very similar shapes, since the warm start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by picking the closest PSP or linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated and almost instantaneous (no optimization or dose calculation needed). The previously developed SAM algorithm is then applied for daily deformation. The authors tested the method on sample prostate and pancreas cases. RESULTS: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. Plan interpolation method is effective in diminishing the unflat beam effect and may allow reducing the required number of PSPs. The whole process takes the same time as the previously reported SAM process (5-10 min). CONCLUSIONS: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation except the delineation of target contour required by the SAM process.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Automação , Humanos , Masculino , Órgãos em Risco , Neoplasias Pancreáticas/radioterapia , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
9.
Radiother Oncol ; 119(3): 371-80, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27162159

RESUMO

Dose escalated radiotherapy improves outcomes for men with prostate cancer. A plateau for benefit from dose escalation using EBRT may not have been reached for some patients with higher risk disease. The use of increasingly conformal techniques, such as step and shoot IMRT or more recently VMAT, has allowed treatment intensification to be achieved whilst minimising associated increases in toxicity to surrounding normal structures. To support further safe dose escalation, the uncertainties in the treatment target position will need be minimised using optimal planning and image-guided radiotherapy (IGRT). In particular the increasing usage of profoundly hypo-fractionated stereotactic therapy is predicated on the ability to confidently direct treatment precisely to the intended target for the duration of each treatment. This article reviews published studies on the influences of varies types of motion on daily prostate position and how these may be mitigated to improve IGRT in future. In particular the role that MRI has played in the generation of data is discussed and the potential role of the MR-Linac in next-generation IGRT is discussed.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Movimento (Física) , Radioterapia de Intensidade Modulada/métodos
10.
Genes Immun ; 16(2): 112-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25521227

RESUMO

Leprosy is a chronic infectious and neurological disease that is caused by infection of Mycobacterium leprae (M. leprae). A recent genome-wide association study indicated a suggestive association of LRRK2 genetic variant rs1873613 with leprosy in Chinese population. To validate this association and further identify potential causal variants of LRRK2 with leprosy, we genotyped 13 LRRK2 variants in 548 leprosy patients and 1078 healthy individuals from Yunnan Province and (re-)analyzed 3225 Han Chinese across China. Variants rs1427267, rs3761863, rs1873613, rs732374 and rs7298930 were significantly associated with leprosy per se and/or paucibacillary leprosy (PB). Haplotype A-G-A-C-A was significantly associated with leprosy per se (P=0.018) and PB (P=0.020). Overexpression of the protective allele (Thr2397) of rs3761863 in HEK293 cells led to a significantly increased nuclear factor of activated T-cells' activity compared with allele Met2397 after lipopolysaccharides stimulation. Allele Thr2397 could attenuate 1-methyl-4-phenyl-1, 2, 3, 6-tetrahydropyridine-induced autophagic activity in U251 cells. These data suggest that the protective effect of LRRK2 variant p.M2397T on leprosy might be mediated by increasing immune response and decreasing neurotoxicity after M. leprae loading. Our findings confirm that LRRK2 is a susceptible gene to leprosy in Han Chinese population.


Assuntos
Povo Asiático/genética , Hanseníase/genética , Proteínas Serina-Treonina Quinases/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Estudos de Associação Genética , Predisposição Genética para Doença , Haplótipos , Humanos , Hanseníase/etnologia , Serina-Treonina Proteína Quinase-2 com Repetições Ricas em Leucina , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Adulto Jovem
11.
Br J Radiol ; 85(1018): e899-905, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22457317

RESUMO

OBJECTIVE: We investigated dosimetric advantages of using helical tomotherapy to simultaneously irradiate the breast and regional lymph nodes for patients positioned prone, and compared tomotherapy plan qualities for the prone position with those previously published for the supine position. METHODS: Tomotherapy plans for 11 patients (5 left breast, 6 right) simulated with the involved breast suspended downward were generated. Each target (ipsilateral breast and supraclavicular, axillary and internal mammary chain nodes) was to receive 45 Gy. RESULTS: For targets, V(40.5)≥99.9% and V(42.8)≥99.5% for all patients, where V(40.5) and V(42.8) denote the relative target volume receiving at least 40.5 and 42.8 Gy, respectively. The targets' maximum dose was, on average, approximately 49.5 Gy. The mean doses to the contralateral lung and heart were lower for right-breast cases (2.8 Gy lung, 2.7 Gy heart) than for left-breast cases (3.8 Gy lung, 8.7 Gy heart). Mean organ doses to the ipsilateral lung (9.3 Gy) and contralateral breast (2.3 Gy) from the prone breast tomotherapy plans were similar to those reported for conventional radiotherapy techniques. For the left breast with regional nodes, tomotherapy plans for prone-positioned patients yielded lower mean doses to the contralateral breast and heart than previously reported data for tomotherapy plans for supine-positioned patients. CONCLUSION: Helical tomotherapy with prone breast positioning can simultaneously cover the breast and regional nodes with acceptable uniformity and can provide reduced mean dose to proximal organs at risk compared with tomotherapy with supine position. The similarity of plan quality to existing data for conventional breast radiotherapy indicates that this planning approach is appropriate, and that the risk of secondary tumour formation should not be significantly greater.


Assuntos
Neoplasias da Mama/radioterapia , Irradiação Linfática/métodos , Posicionamento do Paciente/métodos , Mama/efeitos da radiação , Esôfago/efeitos da radiação , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Linfonodos/efeitos da radiação , Metástase Linfática , Órgãos em Risco/efeitos da radiação , Decúbito Ventral , Doses de Radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Decúbito Dorsal
12.
Technol Cancer Res Treat ; 10(3): 219-29, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21517128

RESUMO

The purpose of this study was to conduct a measurement and treatment planning study on the dosimetric and delivery advantages of a new 160-leaf multileaf collimator (MLC). Recently, a new 160-leaf multileaf collimator (Siemens 160 MLC(TM)) was introduced. The 160-MLC is a single focused design that consists of 160-leafs (80 pairs), each 95 mm thick with a projected leaf width of 5 mm at the machine isocenter. Compared to its double focused predecessors, the 82-leaf MLC (Siemens OPTIVIEW((tm)) MLC) and 58-leaf MLC (Siemens 3-D MLC((tm))), the 160-MLC has leaf widths of half the size. The most notable difference is the new slanted leaf design that replaced the tongue and groove system and allows for complete interdigitation. A systematic study that compared the dosimetric and delivery differences among the 160-MLC, 58-MLC, and divergent Cerrobend blocks was performed. Dosimetric conformity for each collimator type was determined by conforming each to circular targets of various diameters. The effective penumbra for each collimator type was calculated by conforming each, at various collimator angles, to a square stationary target. The quality of 3D conformal radiotherapy treatment (3D-CRT) plans and the quality intensity modulated radiation treatment (IMRT) plans were respectively compared with each collimator type. The 160-MLC was found to have improved dosimetric conformity over the 58-MLC. The divergent Cerrobend block showed marginal dosimetric conformity improvement over the 160-LMC. Overall, the 160-MLC had a 45% and 29% reduction in the 20/80 and 30/90 effective penumbra over the 58-MLC, respectively, while exhibiting only a slightly larger effective penumbra over the divergent Cerrobend block. Comparing 3D-CRT plans generated for small lesions of the head and neck, the V100 for the PTV of the plans generated with the Cerrobend blocks, the 58-MLC, and the 160-MLC were 97.78%, 92.51%, and 99.18%, respectively, while with regards to the OARs, the three produced similar DVHs. IMRT plans generated with the 160-MLC were found to significantly reduce the total delivered monitor units by up to 14.7% and the number of segments by as much as 10.7% compared to the 58-MLC. The average delivery time for the direct aperture optimized (DAO) IMRT plans generated with the 160-MLC was approximately 5 minutes. Overall, compared to the 58-MLC, the new 160-MLC was found to improve dosimetric conformity and IMRT delivery efficiency.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/instrumentação , Adenoma/radioterapia , Desenho de Equipamento , Humanos , Neoplasias Hipofisárias/radioterapia , Radiometria , Dosagem Radioterapêutica
13.
Cancer Gene Ther ; 15(5): 323-30, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18292796

RESUMO

We previously demonstrated that 15-LOX-2 is significantly reduced in head and neck carcinoma and restoration of 15-LOX-2 expression results in tumor inhibition in HNC. The aim of this study is to evaluate 15-LOX-2 as a candidate for targeted radiotherapy. Molecular subcloning was performed to create a radiation-inducible 15-LOX-2 expression vector in which the full-length 15-LOX-2 cDNA was inserted downstream the recombinant Egr-1 promoter. The radiation-induced downregulations of 15-LOX-2 protein (twofold up) and its main metabolite 15S-HETE (threefold up) were observed in HNC cells transfected with the 15-LOX-2 expression vector after 4 Gy of radiation. Radiation-induced upregulation of 15-LOX-2 resulted in significant induction of apoptosis in HNC cells. Furthermore, survival colony formation was significantly reduced by 4 Gy in the HNC cells containing the 15-LOX-2 expression vector compared with the controls. Radiation-induced upregulation of 15-LOX-2 results in significant induction of apoptosis and enhances killing effect of radiotherapy in HNC. In addition, exogenous addition of 15S-HETE at high concentrations (>/=10 muM) but not at low concentrations induced upregulation of its endogenous ligand PPARgamma. In conclusion, synergistic effect between radiation and 15-LOX-2 was observed in killing HNC. 15-LOX-2 may be a potential target in radiation-targeted therapy of HNC. The 15-LOX-2 inhibition may not be PPARgamma dependent.


Assuntos
Araquidonato 15-Lipoxigenase/uso terapêutico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/radioterapia , Lipoxigenase/uso terapêutico , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Araquidonato 15-Lipoxigenase/genética , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Terapia Combinada , Receptores ErbB/genética , Genes Reporter , Vetores Genéticos , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Lipoxigenase/genética , Luciferases/genética , Luciferases/metabolismo , Regiões Promotoras Genéticas
14.
Phys Med Biol ; 53(3): 737-55, 2008 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-18199912

RESUMO

Knowledge of accurate parameter estimates is essential for incorporating normal tissue complication probability (NTCP) models into biologically based treatment planning. The purpose of this work is to derive parameter estimates for the Lyman-Kutcher-Burman (LKB) NTCP model using a combined analysis of multi-institutional toxicity data for the lung (radiation pneumonitis) and parotid gland (xerostomia). A series of published clinical datasets describing dose response for radiation pneumonitis (RP) and xerostomia were identified for this analysis. The data support the notion of large volume effect for the lung and parotid gland with the estimates of the n parameter being close to unity. Assuming that n = 1, the m and TD(50) parameters of the LKB model were estimated by the maximum likelihood method from plots of complication rate as a function of mean organ dose. Ninety five percent confidence intervals for parameter estimates were obtained by the profile likelihood method. If daily fractions other than 2 Gy had been used in a published report, mean organ doses were converted to 2 Gy/fraction-equivalent doses using the linear-quadratic (LQ) formula with alpha/beta = 3 Gy. The following parameter estimates were obtained for the endpoint of symptomatic RP when the lung is considered a paired organ: m = 0.41 (95% CI 0.38, 0.45) and TD(50) = 29.9 Gy (95% CI 28.2, 31.8). When RP incidence was evaluated as a function of dose to the ipsilateral lung rather than total lung, estimates were m = 0.35 (95% CI 0.29, 0.43) and TD(50) = 37.6 Gy (95% CI 34.6, 41.4). For xerostomia expressed as reduction in stimulated salivary flow below 25% within six months after radiotherapy, the following values were obtained: m = 0.53 (95% CI 0.45, 0.65) and TD(50) = 31.4 Gy (95% CI 29.1, 34.0). Although a large number of parameter estimates for different NTCP models and critical structures exist and continue to appear in the literature, it is hard to justify the use of any single parameter set obtained at a selected institution for the purposes of biologically based treatment planning. Our expectation is that the proposed model parameters based on cumulative experience at various institutions are more representative of the overall practice of radiation therapy than any single-institution data, and could be more readily incorporated into clinical use.


Assuntos
Modelos Biológicos , Lesões por Radiação/etiologia , Lesões por Radiação/fisiopatologia , Radioterapia/efeitos adversos , Medição de Risco/métodos , Xerostomia/etiologia , Xerostomia/fisiopatologia , Ensaios Clínicos como Assunto , Simulação por Computador , Relação Dose-Resposta à Radiação , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/fisiopatologia , Valores de Referência , Medição de Risco/normas , Fatores de Risco , Estados Unidos
15.
Br J Radiol ; 81(961): 59-68, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18039721

RESUMO

The purpose of this work was to determine alternative radiotherapy (RT) regimens that are biologically equivalent to clinically proven treatments using different RT modalities or different fractionation schemes. The concept of equivalent uniform dose (EUD) is used with the linear quadratic model to determine equivalent treatment regimens using two representative sets of parameters derived from clinical data: (i) alpha/beta = 3.1 Gy and alpha = 0.15 Gy(-1), and (ii) alpha/beta = 1.5 Gy and alpha = 0.04 Gy(-1). The EUD values for the critical structure (rectum) are also calculated. Representative dose volume histograms were used to account for dose inhomogeneities for different RT modalities. A series of alternative and equivalent fractionation regimens that can be used with different radiotherapy modalities for localized prostate cancer were determined. For example, the alternative regimens, calculated with the alpha/beta ratio of 3.1 Gy, that would be biologically equivalent to external beam RT (EBRT) of 76 Gy (38x2.0 Gy) include: EBRT hypofractionation of 21x3.0 Gy; I-125 implant of 156 Gy; Pd-103 implant of 128 Gy; high dose rate (HDR) brachytherapy of 4x10.5 Gy; I-125 implant of 65 Gy combined with EBRT of 23x2.0 Gy; and HDR brachytherapy of 3x5.9 Gy combined with EBRT of 23x2.0 Gy. Similar data for other parameters are also presented. With caution, the data presented may be useful in designing clinical trials to explore new RT strategies, such as image-guided intensity-modulated RT.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia/métodos , Fracionamento da Dose de Radiação , Humanos , Masculino , Modelos Biológicos , Doses de Radiação , Radioterapia/métodos , Dosagem Radioterapêutica , Reto/efeitos da radiação
16.
Br J Radiol ; 79(947): 905-11, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16885177

RESUMO

Earlier studies have demonstrated that hypoxic regions exist in human prostate cancer and the degree of hypoxia correlates with the treatment outcome of radiotherapy. Using the concept of the clinical oxygen enhancement ratio (COER), the linear-quadratic (LQ) model was extended to account for the effect of tumour hypoxia. The clinical data collected at the Fox Chase Cancer Center for prostate cancer were analysed based on the LQ model as well as the tumour control probability (TCP) model. The LQ and TCP parameters (alpha = 0.15 Gy (-1), alpha/beta = 3.1 Gy and the number of clonogens K = 10(6) approximately 10(7) cells) determined in earlier studies were used to derive the COER for prostate cancer: COER = 1.4 with a standard confidence interval (CI) of (1.2, 1.8). The result is consistent with the in vitro OER measurements of human tumour cell lines under chronic hypoxia conditions. This implies that a higher dose is needed to overcome tumour hypoxia. For prostate tumours, the prescription dose required to overcome tumour hypoxia is 165 Gy (CI: 153 approximately 186 Gy) for permanent 125I implants and 88 Gy (CI: 74 approximately 118 Gy) in 2 Gy fractions for external-beam radiotherapy. The impact of LQ parameters on the calculations of COER and dose escalation was discussed. This study provides a preliminary estimate of the dose escalation needed to overcome tumour hypoxia based on clinical data. More clinical data with better statistics and longer follow-up time are required to further tune the radiobiological modelling of hypoxia for prostate cancer.


Assuntos
Hipóxia/radioterapia , Neoplasias da Próstata/radioterapia , Braquiterapia/métodos , Relação Dose-Resposta à Radiação , Humanos , Hipóxia/etiologia , Masculino , Neoplasias da Próstata/complicações , Resultado do Tratamento
17.
Phys Med Biol ; 48(8): 1075-89, 2003 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-12741503

RESUMO

Intensity-modulated arc therapy (IMAT) is a radiation therapy delivery technique that combines gantry rotation with dynamic multi-leaf collimation (MLC). With IMAT, the benefits of rotational IMRT can be realized using a conventional linear accelerator and a conventional MLC. Thus far, the advantages of IMAT have gone largely unrealized due to the lack of robust automated planning tools capable of producing efficient IMAT treatment plans. This work describes an inverse treatment planning algorithm, called 'direct aperture optimization' (DAO) that can be used to generate inverse treatment plans for IMAT. In contrast to traditional inverse planning techniques where the relative weights of a series of pencil beams are optimized, DAO optimizes the leaf positions and weights of the apertures in the plan. This technique allows any delivery constraints to be enforced during the optimization, eliminating the need for a leaf-sequencing step. It is this feature that enables DAO to easily create inverse plans for IMAT. To illustrate the feasibility of DAO applied to IMAT, several cases are presented, including a cylindrical phantom, a head and neck patient and a prostate patient.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Simulação por Computador , Estudos de Viabilidade , Humanos , Masculino , Imagens de Fantasmas , Controle de Qualidade , Dosagem Radioterapêutica
18.
Med Phys ; 29(6): 1007-18, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12094970

RESUMO

IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture shapes. In this article, we introduce an automated planning system in which we bypass the traditional intensity optimization, and instead directly optimize the shapes and the weights of the apertures. We call this approach "direct aperture optimization." This technique allows the user to specify the maximum number of apertures per beam direction, and hence provides significant control over the complexity of the treatment delivery. This is possible because the machine dependent delivery constraints imposed by the MLC are enforced within the aperture optimization algorithm rather than in a separate leaf-sequencing step. The leaf settings and the aperture intensities are optimized simultaneously using a simulated annealing algorithm. We have tested direct aperture optimization on a variety of patient cases using the EGS4/BEAM Monte Carlo package for our dose calculation engine. The results demonstrate that direct aperture optimization can produce highly conformal step-and-shoot treatment plans using only three to five apertures per beam direction. As compared with traditional optimization strategies, our studies demonstrate that direct aperture optimization can result in a significant reduction in both the number of beam segments and the number of monitor units. Direct aperture optimization therefore produces highly efficient treatment deliveries that maintain the full dosimetric benefits of IMRT.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Relação Dose-Resposta à Radiação , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Radiometria , Software
19.
Int J Cancer ; 96(6): 379-84, 2001 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-11745509

RESUMO

We recently implemented intensity-modulated arc therapy (IMAT) at our institution. In this study, we evaluate the dosimetric merits of the application of this technique to the treatment of prostate cancer. Each IMAT treatment plan incorporated bilateral overlapping arcs. The dose from each beam segment was computed using the three-dimensional dose model of a clinical treatment planning system (Render Plan 3.5, Precision Therapy). The weights assigned to the individual arc segments were optimized using a gradient search method. For 12 patients, comparisons were made between the IMAT treatment plans and corresponding plans using fixed cone-beam intensity-modulated radiotherapy (IMRT) from a commercial inverse planning system (CORVUS, NOMOS Corp.). We found that the optimized IMAT treatments produced similar dose distributions to the IMRT deliveries. Compared with the IMRT treatments, the IMAT treatments produced slightly less target dose homogeneity with consistently greater sparing of the rectum in regions of lower dose. The trade-off between target dose conformity and rectum sparing can be adjusted in both optimization procedures. Because the total beam-on time for IMAT delivery is 1 to 2 minutes with approximately 5-6 minutes of patient setup time, the delivery efficiency of the IMAT treatment was significantly better than the multiple-beam IMRT treatment.


Assuntos
Neoplasias da Próstata/radioterapia , Humanos , Masculino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
20.
Int J Radiat Oncol Biol Phys ; 51(4): 1103-10, 2001 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-11704335

RESUMO

PURPOSE: Guide wires with high torquability and steerability are commonly used to navigate through a tortuous and/or branching arterial tree in a catheter-based intravascular brachytherapy procedure. The dosimetric effects due to the presence of metallic guide wires have not been addressed. This work investigates these dose effects for the three most commonly used beta and gamma sources (90Sr, 32P, and 192Ir). METHODS AND MATERIALS: The EGS4 Monte Carlo codes were used to calculate the dose distributions for the 90Sr(NOVOSTE), 32P (Guidant), and 192Ir (BEST Ind.) with and without a guide wire in place. Energy spectra for particles exiting the sources were calculated from the full phase-space data obtained from the Monte Carlo simulations of the source constructions. Guide wires of various thicknesses and compositions were studied. RESULTS: The dose perturbations due to the presence of guide wires were found to be far more significant for the 90Sr/90Y and 32P beta sources than those for the 192Ir gamma source. Because of the attenuation by the guide wires, a dose reduction of up to 60% behind a guide wire was observed for the beta sources, whereas the dose perturbation was found to be negligible for the gamma source. For a beta source, the dose perturbations depend on the thickness and the material of the guide wire. When the region behind a guide wire is part of an intravascular brachytherapy target, the presence of the guide wire results in a significant underdosing for beta sources. The underdosed region can extend a few mm behind the guide wire and up to 1 mm in other directions. CONCLUSION: Significant dose perturbations by the presence of a metallic guide wire have been found in catheter-based intravascular brachytherapy using beta sources. The dose effects should be considered in the dose prescription and/or in analyzing the treatment outcome for beta sources. Such precautions are not necessary if using a gamma source.


Assuntos
Vasos Sanguíneos , Braquiterapia/instrumentação , Cateterismo/instrumentação , Dosagem Radioterapêutica , Partículas beta , Raios gama , Radioisótopos de Irídio , Método de Monte Carlo , Radioisótopos de Fósforo , Radiometria , Radioisótopos de Estrôncio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...