Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Bone Joint J ; 104-B(1): 19-26, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34969272

RESUMO

AIMS: Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. METHODS: In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. RESULTS: Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months. Radiolucent lines measuring < 2 mm wide were found in three and five arthroplasties cemented by the standard and line-to-line method, respectively. CONCLUSION: The cemented Corail stem with a force-closed design seems to settle earlier and better with the line-to-line cementing method, although for subsidence the difference was not significant. However, the lower rate of migration into retroversion may reduce the wear and cement deformation, contributing to good long-term fixation and implant survival. Cite this article: Bone Joint J 2022;104-B(1):19-26.


Assuntos
Artroplastia de Quadril/métodos , Cimentação/métodos , Prótese de Quadril , Idoso , Cimentos Ósseos , Feminino , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Noruega , Falha de Prótese , Análise Radioestereométrica , Rotação , Método Simples-Cego
2.
Bone Jt Open ; 2(9): 737-744, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34493056

RESUMO

AIMS: Medial pivot (MP) total knee arthroplasties (TKAs) were designed to mimic native knee kinematics with their deep medial congruent fitting of the tibia to the femur almost like a ball-on-socket, and a flat lateral part. GMK Sphere is a novel MP implant. Our primary aim was to study the migration pattern of the tibial tray of this TKA. METHODS: A total of 31 patients were recruited to this single-group radiostereometric analysis (RSA) study and received a medial pivot GMK Sphere TKA. The distributions of male patients versus female patients and right versus left knees were 21:10 and 17:14, respectively. Mean BMI was 29 kg/m2 (95% confidence interval (CI) 27 to 30) and mean age at surgery was 63 years (95% CI 61 to 66). Maximum total point motions (MTPMs), medial, proximal, and anterior translations and transversal, internal, and varus rotations were calculated at three, 12, and 24 months. Patient-reported outcome measure data were also retrieved. RESULTS: MTPMs at three, 12, and 24 months were 1.0 mm (95% CI 0.8 to 1.2), 1.3 mm (95% CI 0.9 to 1.7), and 1.4 mm (0.8 to 2.0), respectively. The Forgotten Joint Score was 79 (95% CI 39 to 95) and Knee Injury and Osteoarthritis Outcome Score obtained at two years was 94 (95% CI 81 to 100), 86 (95% CI 75 to 93), 94 (95% CI 88 to 100), 69 (95% CI 48 to 88), and 81 (95% CI59 to 100) for Pain, Symptoms, Activities of Daily Living, Sport & Recreation, and Quality of Life, respectively. CONCLUSION: In conclusion, we found that the mean increase in MTPM was lower than 0.2 mm between 12 and 24 months and thus apparently stable. Yet the GMK Sphere had higher migration at one and two years than anticipated. Based on current RSA data, we therefore cannot conclude on the long-term performance of the implant, pending further assessment. Cite this article: Bone Jt Open 2021;2(9):737-744.

3.
BMC Musculoskelet Disord ; 21(1): 287, 2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32384890

RESUMO

BACKGROUND: Focal cartilage defects (FCDs) in the knee joint has a high prevalence. A broad range of treatment options exists for symptomatic patients. Knowledge of patient compensation claims following surgical treatment of FCDs is missing. The purpose of this study is to evaluate compensation claims filed to the Scandinavian registries for patient compensation following treatment of FCDs in the knee joint from 2010 to 2015 and identify possible areas of improvement. METHODS: A cross-sectional study design was used to obtain all complaints following surgical treatment of FCDs from the Scandinavian registries from 2010 to 2015. Data such as age, gender, type of treatment, type of complaint, reason of verdict and amount of compensation were collected and systematically analyzed. RESULTS: 103 patients filed a compensation claim. 43 had received debridement (41.7%), 54 microfracture (MF) (52.4%), 3 mosaicplasty (2.9%) and 3 autologous chondrocyte implantation (ACI) (2.9%). Of the 103 claims, 36 were granted (35%). 21 following debridement (58.3%), 13 after MF (36.1%), 1 following mosaicplasty (2.8%) and 1 after ACI (2.8%). The most common reason for complaint was infection (22.1%), of which 89% were granted. The average compensation was €24.457 (range €209 - €458.943). CONCLUSION: Compensation claims following surgical treatment of knee cartilage injuries in Scandinavia are rare. Establishing nationwide cartilage registries can add further knowledge on this troublesome disease.


Assuntos
Doenças das Cartilagens/cirurgia , Compensação e Reparação , Revisão da Utilização de Seguros/economia , Traumatismos do Joelho/cirurgia , Procedimentos Ortopédicos/efeitos adversos , Sistema de Registros , Infecção da Ferida Cirúrgica/etiologia , Adolescente , Adulto , Idoso , Doenças das Cartilagens/epidemiologia , Cartilagem Articular/fisiopatologia , Cartilagem Articular/cirurgia , Criança , Estudos Transversais , Desbridamento , Feminino , Fraturas de Estresse/etiologia , Humanos , Traumatismos do Joelho/epidemiologia , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/métodos , Países Escandinavos e Nórdicos/epidemiologia , Adulto Jovem
4.
Clin Orthop Relat Res ; 478(6): 1207-1218, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31977446

RESUMO

BACKGROUND: The medial pivot TKA design was introduced in the 1990s. These are fixed-bearing, medial-conforming implants with virtually no translation in the medial part of the knee, in contrast to the flat lateral part of the insert allowing for translation similar to the native knee during flexion and extension. Most primary TKAs performed in Norway and Australia are cruciate-retaining. All of the medial pivot implants in our study are cruciate-sacrificing but without a post-cam mechanism. The medial pivot implant design was developed to more closely mimic native knee motion, in the hope of improving function, and not primarily as a more constrained knee for difficult cases. In the past 10 to 12 years, a second-generation medial-pivot design has emerged, but there are no larger registry studies on the survival of these implants. Both cruciate-retaining and medial pivot designs are reported in the Australian and Norwegian registries, allowing for large-scale, comparative survivorship studies. QUESTIONS/PURPOSES: (1) Is there any difference in survival between the medial pivot design and the three most commonly used cruciate-retaining TKA designs? (2) Is there any difference in survival among the different medial pivot implant designs? (3) What are the main indications for revision of medial pivot TKAs? METHODS: Registry data from the Australian Orthopaedic Association National Joint Replacement Registry and Norwegian Arthroplasty Register from 2005 until the end of 2017 were used to compare the five different brands of medial pivot TKA designs (total primary TKAs assessed: 6310). In Australia, the study group of medial pivot implants represented 9% (6012 of 72,477) of the total number of cemented/hybrid TKAs without patellar resurfacing; 345 had cementless femoral components. In Norway, the study group represented 1% (298 of 47,820) of the total number of TKAs with cemented tibias without patellar resurfacing; all had cemented femoral components. The control group consisted of the three most commonly used cruciate-retaining TKA designs (n = 70,870; Australia n = 54,554; Norway n = 16,316). All TKAs used a fixed-bearing, cemented tibial component and did not involve patella resurfacing. Kaplan-Meier survival analysis was assessed to estimate survivorship. We compared the groups by calculating the hazard ratios (HR) using Cox regression adjusted for age, gender and preoperative diagnosis with 95% CI. To answer our third question, we calculated the percentage of each revision indication from the total number of revisions in each group, and used a Cox regression analysis to compare revision causes and HRs. Analyses were performed separately by each registry. Accounting for competing risks (Fine and Gray) did not alter our findings []. RESULTS: After controlling for potential confounding variables such as gender, age and preoperative diagnosis, we found an increased revision risk for the medial pivot compared with cruciate-retaining TKA designs in Australia (HR 1.4 [95% CI 1.2 to 1.7]; p < 0.001), but not in Norway (HR 1.5 [95% CI 0.9 to 2.4]; p = 0.1). Two brands of the medial pivot design reported to the AOANJRR showed an increased risk of revision compared with cruciate-retaining designs: the Advance® II MP (HR 1.7 [95% CI 1.2 to 2.6]; p = 0.004) and the GMK® Sphere (HR 2.0 [95% CI 1.5 to 2.6]; p < 0.001), whereas the MRK (HR 0.7 [95% CI 0.4 to 1.5]; p = 0.4), the Evolution® MP (HR 1.4 [95% CI 1.0 to 1.9]; p = 0.06) and the SAIPH® (HR 0.9 [95% CI 0.5 to 1.5]; p = 0.7) showed no difference. The most common reasons for revision of medial pivot implants in Australia were infection (27%), pain alone (19%), patellar erosion (13%), loosening/lysis (12%); in Norway the primary indications were loosening/lysis (28%), instability (28%), malalignment (11%) and pain alone (11%). CONCLUSIONS: The medial pivot TKA design as a group had a higher revision rate than cruciate-retaining fixed-bearing controls in TKA performed without patellar component resurfacing. By brand, the Advance II MP and the GMK Sphere had inferior survivorship, whereas the MRK, the SAIPH and the Evolution MP had no differences in survivorship compared with cruciate-retaining controls. In Australia, TKAs with the medial pivot design without patella resurfacing had a higher rate of revisions for instability, malalignment, and patella erosion. In Norway, there was an increased risk of revision for lysis and loosening compared with the cruciate-retaining design. Several of these implants had short follow-up in this study. Further registry studies with longer follow up are therefore necessary. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Prótese do Joelho , Ligamentos Articulares/cirurgia , Patela/cirurgia , Desenho de Prótese , Falha de Prótese , Idoso , Artroplastia do Joelho/efeitos adversos , Austrália , Fenômenos Biomecânicos , Bases de Dados Factuais , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Noruega , Patela/diagnóstico por imagem , Patela/fisiopatologia , Amplitude de Movimento Articular , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
5.
Osteoarthr Cartil Open ; 1(3-4): 100018, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-36475003

RESUMO

Objective: MicroRNAs (miRNAs) are being launched as biomarkers for various diseases, but a robust biomarker for articular cartilage pathology has yet to be discovered. Here we evaluate plasma extracellular vesicle (EV) miRNAs as possible biomarkers for osteoarthritis (OA). Method: We compared miRNA levels found in plasma EVs from patients with OA with controls without OA using next generation sequencing (NGS) technique. The patient and control pairs were matched for age, gender and body mass index. Results: 23 pairs of patients and controls were included. Patients with OA differed significantly from controls in both clinical and radiological assessment of OA. We identified 177 canonical miRNAs in plasma EVs, but found no difference in miRNA levels between the two groups. Interestingly, the concentration of each miRNA in plasma EVs showed minimal difference between the participants, suggesting that the release of miRNAs in EVs from cells within the various organs is a tightly controlled process. Conclusion: This is the first study using NGS in search of a miRNA biomarker in plasma EVs in OA. The levels of each plasma EVs miRNA were surprisingly similar for all participants. No plasma EVs miRNA can be used as a biomarker for OA.

6.
Knee Surg Sports Traumatol Arthrosc ; 26(4): 1044-1052, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29128878

RESUMO

PURPOSE: Focal cartilage defects in the knee may have devastating effect on the knee joint, where two of the main surgical treatment options are microfracture and autologous chondrocyte implantation. Comparative studies have failed to establish which method yields the best clinical results. A cost-effectiveness analysis of microfracture and autologous chondrocyte implantation would contribute to the clinical decision process. METHODS: A PubMed search identifying level I and level II studies with 5 year follow-up was performed. With the data from these studies, decision trees with associated service provision and costs connected to the two different techniques were designed. In addition to hospital costs, we included costs connected to physiotherapy following surgery. To paint a broader cost picture, we also included indirect costs to the society due to productivity loss caused by work absence. RESULTS: Four high-quality studies, with a follow-up of 5 years, met the inclusion criteria. A total of 319 patients were included, 170 undergoing microfracture and 149 autologous chondrocyte implantation. The re-operation rate was 23 (13.5%) following microfracture, and 18 (12.1%) for autologous chondrocyte implantation. Both groups achieved substantially better clinical scores at 5 years compared to baseline. Microfracture was more cost-effective when comparing all clinical scores. CONCLUSION: Microfracture is associated with both lower costs and lower cost per point increase in patient reported outcome measures. There is a need of well-designed, high-quality randomized controlled trials before reliable conclusions regarding cost-effectiveness in the long run is possible. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia Subcondral/economia , Cartilagem Articular/cirurgia , Condrócitos/transplante , Traumatismos do Joelho/cirurgia , Transplante Autólogo/economia , Cartilagem Articular/lesões , Análise Custo-Benefício , Humanos , Traumatismos do Joelho/economia , Medidas de Resultados Relatados pelo Paciente , Reoperação/estatística & dados numéricos
7.
Arthroscopy ; 30(8): 936-41, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24863404

RESUMO

PURPOSE: The purpose of this study was to assess the effect of smoking on supraspinatus tendon degeneration, including cellular alterations, proliferation, and apoptosis of tendon cells. METHODS: Supraspinatus tendon samples of 10 smokers and 15 nonsmokers with full-thickness tears were compared, focusing on the severity of tendon histopathology including apoptosis (programmed cell death), cellularity, and proliferation. Immunohistochemistry was used to assess the density of apoptotic cells and proliferation. The extent of tendon degeneration was classified according to a revised version of the Bonar tendon histopathology score. RESULTS: The smokers were younger (P = .01). The symptom duration among smokers was longer (P < .05). The supraspinatus tendons from the smokers presented significantly more advanced degenerative changes (Bonar score, 13.5 [interquartile range, 1.4] v 9 [interquartile range, 3]; P < .001). The smokers' tendons showed increased density of apoptotic cells (0.108 [SE, 0.038] v 0.0107 [SE, 0.007]; P = .024) accompanied by reduced tenocyte density (P = .019) and upregulation of proliferative activity (P < .0001). CONCLUSIONS: Smoking is associated with worsened supraspinatus tendon histopathology and increased apoptosis. CLINICAL RELEVANCE: Pronounced degenerative changes, reduced tendon cellularity, and increased apoptosis may indicate reduced tendon healing capacity in smokers.


Assuntos
Manguito Rotador/patologia , Fumar/efeitos adversos , Apoptose , Proliferação de Células , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Manguito Rotador/cirurgia , Lesões do Manguito Rotador , Fumar/fisiopatologia , Cicatrização
8.
Acta Orthop ; 84(6): 565-70, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24171689

RESUMO

BACKGROUND AND PURPOSE: Rotator cuff tears are associated with secondary rotator cuff muscle pathology, which is definitive for the prognosis of rotator cuff repair. There is little information regarding the early histological and immunohistochemical nature of these muscle changes in humans. We analyzed muscle biopsies from patients with supraspinatus tendon tears. METHODS: Supraspinatus muscle biopsies were obtained from 24 patients undergoing arthroscopic repair of partial- or full-thickness supraspinatus tendon tears. Tissue was formalin-fixed and processed for histology (for assessment of fatty infiltration and other degenerative changes) or immunohistochemistry (to identify satellite cells (CD56+), proliferating cells (Ki67+), and myofibers containing predominantly type 1 or 2 myosin heavy chain (MHC)). Myofiber diameters and the relative content of MHC1 and MHC2 were determined morphometrically. RESULTS: Degenerative changes were present in both patient groups (partial and full-thickness tears). Patients with full-thickness tears had a reduced density of satellite cells, fewer proliferating cells, atrophy of MHC1+ and MHC2+ myofibers, and reduced MHC1 content. INTERPRETATION: Full-thickness tears show significantly reduced muscle proliferative capacity, myofiber atrophy, and loss of MHC1 content compared to partial-thickness supraspinatus tendon tears.


Assuntos
Regeneração/fisiologia , Lesões do Manguito Rotador , Traumatismos dos Tendões/patologia , Apoptose/fisiologia , Artroscopia , Biópsia , Proliferação de Células , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Musculares Esqueléticas/patologia , Proteínas Musculares/metabolismo , Atrofia Muscular/patologia , Manguito Rotador/patologia , Manguito Rotador/fisiologia , Manguito Rotador/cirurgia , Células Satélites de Músculo Esquelético/patologia , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia
9.
Br J Sports Med ; 45(13): 1035-9, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21482545

RESUMO

Little information exists on the contribution of apoptosis to pathological tendon changes in rotator cuff tendinopathy. The purpose of this study was to quantitate the rate of tenocyte apoptosis in torn supraspinatus tendons and in the matched intact subscapularis and to examine the potential relation between apoptotic index (AI) and tendon pathology. In addition, the authors examined tenocyte density, proliferation rate and p53 gene expression patterns to gain further insight into relevant pathological mechanisms in the torn suprapinatus. 15 torn supraspinatus tendons with matched intact subscapularis tendon samples and 10 reference subscapularis samples were collected. Immunohistochemistry was used to define the AI (F7-26), proliferation rate (Ki67) and presence of p53 (M7001). Tendon degeneration was evaluated according to the Bonar scale. Expression of p53 and relevant genes (n=84) was examined on a subset of samples using microfluidic arrays. The AI was significantly increased in torn supraspinatus tendon and matched subscapularis tendon (R² =0.5742; p=0.0005). Cell density and proliferation rate were also elevated in torn supraspinatus compared with reference subscapularis tendons (p<0.05). A significant increase in p53 occurred specifically in torn supraspinatus tendon (p<0.05), and several genes encoding p53-inhibiting proteins were downregulated in association, including HDAC1 (p<0.05), MDM4 (p<0.001) and PPM1D (p<0.05). Our results suggest that tenocyte apoptosis results from more than one mechanism in the injured rotator cuff, including both intrinsic factors related specifically to the torn supraspinatus tendon, as well as a more generalised effect on the adjacent subscapularis tendon.


Assuntos
Apoptose/fisiologia , Lesões do Manguito Rotador , Tendinopatia/patologia , Idoso , Apoptose/genética , Proliferação de Células , Feminino , Expressão Gênica , Genes p53 , Humanos , Masculino , Pessoa de Meia-Idade , RNA Mensageiro/metabolismo , Manguito Rotador/patologia , Ruptura/patologia , Proteína Supressora de Tumor p53/antagonistas & inibidores , Proteína Supressora de Tumor p53/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...