Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 7(1): 14093, 2017 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-29074971

RESUMO

Quantitative hepatitis B core antigen (anti-HBc) measurements could play an important role in evaluating therapeutic outcomes and optimizing the antiviral therapy of chronic hepatitis B infection. In this study, we have developed a simple and rapid fluorescence point-of-care test based on a lateral flow immunoassay (LFIA) method integrated with Eu (III) chelate microparticles to quantitatively determine anti-HBc concentrations in serum. This assay is based on a direct competitive immunoassay performed on lateral flow test strips with an assay time of 15 min. The Eu (III) chelate microparticle-based LFIA assay could quantitatively detect anti-HBc levels with a limit of detection of 0.31 IU mL-1, and exhibited a wide linear range (0.63-640 IU mL-1). The intra- and inter-assay coefficients of variation for anti-HBc were both less than 10% and a satisfactory dilution test and accuracy were demonstrated. There were no statistically significant differences in sensitivity or specificity in serum samples between the Eu (III) chelate microparticle-based LFIA strips and the Abbott Architect kit. A simple, rapid and effective quantitative detection of anti-HBc was possible using the Eu (III) chelate microparticle-based LFIA strips. The strips will provide diagnostic value for clinical application.


Assuntos
Antígenos do Núcleo do Vírus da Hepatite B/análise , Imunoensaio/instrumentação , Calibragem , Antígenos do Núcleo do Vírus da Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Humanos , Imunoensaio/métodos , Microtecnologia , Compostos Organometálicos , Sensibilidade e Especificidade , Fatores de Tempo
2.
Sensors (Basel) ; 17(3)2017 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-28264502

RESUMO

Procalcitonin (PCT) is a current, frequently-used marker for severe bacterial infection. The aim of this study was to develop a cost-effective detection kit for rapid quantitative and on-site detection of PCT. To develop the new PCT quantitative detecting kit, a double-antibody sandwich immunofluorescent assay was employed based on time-resolved immunofluorescent assay (TRFIA) combined with lateral flow immunoassay (LFIA). The performance of the new developed kit was evaluated in the aspects of linearity, precision, accuracy, and specificity. Two-hundred thirty-four serum samples were enrolled to carry out the comparison test. The new PCT quantitative detecting kit exhibited a higher sensitivity (0.08 ng/mL). The inter-assay coefficient of variation (CV) and the intra-assay CV were 5.4%-7.7% and 5.7%-13.4%, respectively. The recovery rates ranged from 93% to 105%. Furthermore, a high correlation (n = 234, r = 0.977, p < 0.0001) and consistency (Kappa = 0.875) were obtained when compared with the PCT kit from Roche Elecsys BRAHMS. Thus, the new quantitative method for detecting PCT has been successfully established. The results indicated that the newly-developed system based on TRFIA combined with LFIA was suitable for rapid and on-site detection for PCT, which might be a useful platform for other biomarkers in point-of-care tests.


Assuntos
Cromatografia de Afinidade , Biomarcadores , Calcitonina , Peptídeo Relacionado com Gene de Calcitonina , Sistemas Automatizados de Assistência Junto ao Leito , Precursores de Proteínas
3.
J Fluoresc ; 27(1): 309-316, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27878521

RESUMO

In this paper, a novel time-resolved fluorescence immunoassay (TRFIA) is described that allows the simultaneous quantitative detection of hepatitis B virus surface antigen (HBsAg) and hepatitis B e antigen (HBeAg) in human serum to aid the diagnosis and monitoring of hepatitis B virus infection. The proposed method was developed based on a two-step sandwich immunoassay protocol in which monoclonal antibodies against HBsAg and HBeAg were co-coated in 96 microtitration wells, then tracer polyclonal antibodies against HBsAg labeled with samarium and tracer monoclonal antibodies against HBeAg labeled with europium chelates were used for detection. The detection range was 0.1-150 IU/mL for HBsAg and 0.5-160 PEIU/mL for HBeAg, and the detection limits were 0.03 IU/L and 0.09 PEIU/ml, respectively. The intra- and inter-assay coefficients of variation were below 8 % for both virus antigens. The dilution linearity and accuracy of the assay were satisfactory. No statistically significant differences were observed in sensitivity or specificity for the serum samples between the dual-label TRFIA and a commercial single-label TRFIA. These results demonstrate that an effective, reliable and convenient HBsAg/HBeAg dual-label TRFIA was successfully developed that may be clinically applicable for blood screening to monitor the course of hepatitis B virus infection and predict treatment responses.


Assuntos
Fluorimunoensaio/métodos , Antígenos de Superfície da Hepatite B/sangue , Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , China/epidemiologia , Hepatite B/epidemiologia , Hepatite B/virologia , Humanos , Indicadores e Reagentes
4.
J Fluoresc ; 26(3): 987-96, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27034063

RESUMO

The isoenzyme creatine kinase MB is very important for diagnosis of acute myocardial infarction (AMI). Some CK-MB immunoassays are sensitive, accurate and available for clinical application, but they are expensive and time-consuming procedures. Furthermore, conventional fluorescence immunochromatographic assays (FL-ICAs) have suffered from background fluorescence interference and low analytical sensitivity. A rapid and simple FL-ICA with Eu (III) chelate polystyrene microparticles was developed to determine CK-MB in 50uL serum samples using a portable test strip reader by measuring the fluorescence peak heights of the test line (HT) and the control line (HC) in 12 min. The assay was reliable with a good correlation coefficient between HT/HC ratio and CK-MB concentration in samples. A linear range was 0.85-100.29 ng/mL for CK-MB, and the LOD was 0.029 ng/mL. The intra- and inter-assay coefficients of variation (CV) were both <10 % and the average recoveries were from 90.17 % -112.63 % for CK-MB. The system performed well in interference experiments. Furthermore, a highly significant correlation (r = 0.9794, P < 0.001) between this method and the commercially available bioMérieux mini VIDAS system were attained for measuring 120 CK-MB samples. These results indicated that the Eu (III) chelate microparticles-based FL-ICA is simple, fast, highly sensitive, reliable, and reproducible for point-of-care testing of CK-MB concentrations in serum. Graphical Abstract ᅟ.


Assuntos
Quelantes/química , Cromatografia de Afinidade/métodos , Creatina Quinase Forma MB/metabolismo , Európio/química , Microesferas , Cromatografia de Afinidade/instrumentação , Poliestirenos/química , Fitas Reagentes/química , Valores de Referência , Espectrometria de Fluorescência , Fatores de Tempo
5.
PLoS One ; 11(1): e0146997, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26765738

RESUMO

OBJECTIVE: The fraction of circulating cell-free fetal (cff) DNA in maternal plasma is a critical parameter for aneuploidy screening with non-invasive prenatal testing, especially for those samples located in equivocal zones. We developed an approach to quantify cff DNA fractions directly with sequencing data, and increased cff DNAs by optimizing library construction procedure. METHODS: Artificial DNA mixture samples (360), with known cff DNA fractions, were used to develop a method to determine cff DNA fraction through calculating the proportion of Y chromosomal unique reads, with sequencing data generated by Ion Proton. To validate our method, we investigated cff DNA fractions of 2,063 pregnant women with fetuses who were diagnosed as high risk of fetal defects. The z-score was calculated to determine aneuploidies for chromosomes 21, 18 and 13. The relationships between z-score and parameters of pregnancies were also analyzed. To improve cff DNA fractions in our samples, two groups were established as follows: in group A, the large-size DNA fragments were removed, and in group B these were retained, during library construction. RESULTS: A method to determine cff DNA fractions was successfully developed using 360 artificial mixture samples in which cff DNA fractions were known. A strong positive correlation was found between z-score and fetal DNA fraction in the artificial mixture samples of trisomy 21, 18 and 13, as well as in clinical maternal plasma samples. There was a positive correlation between gestational age and the cff DNA fraction in the clinical samples, but no correlation for maternal age. Moreover, increased fetal DNA fractions were found in group A compared to group B. CONCLUSION: A relatively accurate method was developed to determine the cff DNA fraction in maternal plasma. By optimizing, we can improve cff DNA fractions in sequencing samples, which may contribute to improvements in detection rate and reliability.


Assuntos
Aneuploidia , Sequenciamento de Nucleotídeos em Larga Escala , Diagnóstico Pré-Natal/métodos , Adulto , Transtornos Cromossômicos/diagnóstico , Transtornos Cromossômicos/genética , Feminino , Feto , Humanos , Masculino , Gravidez , Adulto Jovem
6.
Anal Chim Acta ; 891: 277-83, 2015 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-26388387

RESUMO

Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (HT) and the control line (HC); the HT/HC ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0-1000 IU mL(-1)) for AFP with a low limit of detection (0.1 IU mL(-1)) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing.


Assuntos
Quelantes/química , Európio/química , Fluorimunoensaio/instrumentação , Fitas Reagentes/análise , alfa-Fetoproteínas/análise , Desenho de Equipamento , Fluorimunoensaio/economia , Humanos , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito
7.
Clin Biochem ; 48(9): 603-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25633154

RESUMO

OBJECTIVES: This study established a novel time-resolved fluorescence immunoassay (TRFIA) that allows the simultaneous determination of rubella virus (RV) IgM and cytomegalovirus (CMV) IgM in human serum. DESIGN AND METHODS: Lanthanum elements labeled antibody and streptavidin-biotin system were used in the "capture sandwich" format simultaneously. RESULTS: The working range of TRFIA for RV IgM was 2-80 AU/mL and for CMV IgM was 5-400 AU/mL. Intra- and inter-assay coefficient of variation (CV) for RV IgM and CMV IgM were both less than 10% and recoveries were from 90% to 110%. No significant statistical difference in sensitivity or specificity was observed between dual-TRFIA and commercial chemiluminescent immunoassays (CLIA) in serum samples. CONCLUSION: The novel dual-TRFIA for RV IgM and CMV IgM detection might have valuable clinical application, with satisfactory sensitivity, specificity and accuracy.


Assuntos
Anticorpos Antivirais/sangue , Citomegalovirus/imunologia , Fluorimunoensaio/métodos , Imunoglobulina M/sangue , Vírus da Rubéola/imunologia , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...