Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
3.
J Pediatr ; 262: 113648, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37517651

RESUMO

OBJECTIVE: To use cerebral near-infrared spectroscopy (NIRS) to quantify occult cerebral hypoxia across respiratory support modes in preterm infants. STUDY DESIGN: In this prospective, longitudinal, observational study, infants ≤32 weeks gestation underwent serial pulse oximetry (oxygen saturation [SpO2]) and cerebral NIRS monitoring (4-6 hours per session) following a standardized recording schedule (daily for 2 weeks, every other day for 2 weeks, then weekly until 35 weeks corrected gestational age). Four calculations were made: median cerebral saturation, median cerebral hypoxia burden (proportion of NIRS samples below the hypoxia threshold [<67%]), median systemic saturation, and median systemic hypoxia burden (proportion of SpO2 samples below the desaturation threshold [<85%]). During each recording session, respiratory support mode was noted (room air, low-flow nasal cannula, high-flow nasal cannula, noninvasive positive pressure ventilation, continuous positive airway pressure, and invasive ventilation). RESULTS: There were 1013 recording sessions made from 174 infants with a median length of 6.9 hours. Although the systemic (SpO2) hypoxia burden was significantly greater for infants on the highest respiratory support (invasive and noninvasive positive pressure ventilation), the cerebral hypoxia burden was significantly greater during recording sessions made on the lowest respiratory support (8% for room air; 29% for low-flow nasal cannula). CONCLUSIONS: Premature infants on the highest levels of respiratory support have less cerebral hypoxia than those on lower respiratory support. These results raise concern about unrecognized cerebral hypoxia during lower acuity periods of neonatal intensive care unit hospitalization and adverse outcomes.


Assuntos
Hipóxia Encefálica , Recém-Nascido Prematuro , Lactente , Recém-Nascido , Humanos , Estudos Prospectivos , Incidência , Hipóxia Encefálica/etiologia , Hipóxia/etiologia , Oximetria/métodos , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Oxigênio
4.
J Am Soc Echocardiogr ; 36(9): 967-977, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37331608

RESUMO

BACKGROUND: Right ventricular (RV) function is important in the evaluation of cardiac function, but its assessment using standard transthoracic echocardiography (TTE) remains challenging. Cardiac magnetic resonance imaging (CMR) is considered the gold standard. The American Society of Echocardiography recommends surrogate measures of RV function and RV ejection fraction (RVEF) by TTE, including fractional area change (FAC), free wall strain (FWS), and tricuspid annular planar systolic excursion (TAPSE), but they require technical expertise in acquisition and quantification. METHODS: The aim of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of FAC, FWS, and TAPSE derived using a rapid, novel artificial intelligence (AI) software (LVivoRV) from a single-plane transthoracic echocardiographic apical four-chamber, RV-focused view without ultrasound-enhancing agents for detecting abnormal RV function compared with CMR-derived RVEF. RV dysfunction was defined as RVEF < 50% and RVEF < 40% on CMR. RESULTS: TTE and CMR were performed within a median of 10 days (interquartile range, 2-32 days) of each other in 225 consecutive patients without interval procedural or pharmacologic intervention. The sensitivity and negative predictive value to detect CMR-defined RV dysfunction when all three AI-derived parameters (FAC, FWS, and TAPSE) were abnormal were 91% and 96%, while those of expert physician reads were 91% and 97%. Specificity and positive predictive value were lower (50% and 32%) compared with expert physician-read echocardiograms (82% and 56%). CONCLUSIONS: AI-derived measurements of FAC, FWS, and TAPSE had excellent sensitivity and negative predictive value for ruling out significant RV dysfunction (CMR RVEF < 40%), comparable with that of expert physician readers, but lower specificity. Thus AI, using American Society of Echocardiography guidelines, may serve as a useful screening tool for rapid bedside assessment to exclude significant RV dysfunction.


Assuntos
Disfunção Ventricular Direita , Humanos , Disfunção Ventricular Direita/diagnóstico por imagem , Inteligência Artificial , Imagem Cinética por Ressonância Magnética/métodos , Ecocardiografia , Imageamento por Ressonância Magnética , Volume Sistólico , Função Ventricular Direita
5.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1709-1716, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227360

RESUMO

BACKGROUND: Sustained ventricular tachycardia and sudden cardiac death due to degenerative mitral valve prolapse (MVP) can occur in the absence of severe mitral regurgitation (MR). A significant percentage of patients with MVP-related sudden death do not have any evidence of replacement fibrosis, suggesting other unrecognized proarrhythmic factors may place these patients at risk. OBJECTIVES: This study aims to characterize myocardial fibrosis/inflammation and ventricular arrhythmia complexity in patients with MVP and only mild or moderate MR. METHODS: Prospective observational study of patients with MVP and only mild or moderate MR underwent ventricular arrhythmia characterization and hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI). Coregistered hybrid 18F-fluorodeoxyglucose (18F-FDG)-PET and MRI late gadolinium enhancement images were assessed and categorized. Recruitment occurred in the cardiac electrophysiology clinic. RESULTS: In 12 patients with degenerative MVP with only mild or moderate MR, of which a majority had complex ventricular ectopy (n = 10, 83%), focal (or focal-on-diffuse) uptake of 18F-FDG (PET-positive) was detected in 83% (n = 10) of patients. Three-quarters of the patients (n = 9, 75%) had FDG uptake that coexisted with areas of late gadolinium enhancement (PET/MRI-positive). Abnormal T1, T2 and extracellular volume (ECV) values were observed in 58% (n = 7), 25% (n = 3), and 16% (n = 2), respectively. CONCLUSIONS: Most patients with degenerative MVP, ventricular ectopy, and mild or moderate MR show myocardial inflammation that is concordant with myocardial scar. Further study is needed to determine whether these findings contribute to the observation that most MVP-related sudden deaths occur in patients with less than severe MR.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Complexos Ventriculares Prematuros , Humanos , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Meios de Contraste , Gadolínio , Fluordesoxiglucose F18 , Fibrose , Inflamação
7.
Echocardiography ; 39(3): 473-482, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35178746

RESUMO

BACKGROUND: Quantification of left ventricular ejection fraction (LVEF) by transthoracic echocardiography (TTE) is operator-dependent, time-consuming, and error-prone. LVivoEF by DIA is a new artificial intelligence (AI) software, which displays the tracking of endocardial borders and rapidly quantifies LVEF. We sought to assess the accuracy of LVivoEF compared to cardiac magnetic resonance imaging (cMRI) as the reference standard and to compare LVivoEF to the standard-of-care physician-measured LVEF (MD-EF) including studies with ultrasound enhancing agents (UEAs). METHODS: In 273 consecutive patients, we compared MD-EF and AI-derived LVEF to cMRI. AI-derived LVEF was obtained from a non-UEA four-chamber view without manual correction. Thirty-one patients were excluded: 25 had interval interventions or incomplete TTE or cMRI studies and six had uninterpretable non-UEA apical views. RESULTS: In the 242 subjects, the correlation between AI and cMRI was r = .890, similar to MD-EF and cMRI with r = .891 (p = 0.48). Of the 126 studies performed with UEAs, the correlation of AI using the unenhanced four-chamber view was r = .89, similar to MD-EF with r = .90. In the 116 unenhanced studies, AI correlation was r = .87, similar to MD-EF with r = .84. From Bland-Altman analysis, LVivoEF underreported the LVEF with a bias of 3.63 ± 7.40% EF points compared to cMRI while MD-EF to cMRI had a bias of .33 ± 7.52% (p = 0.80). CONCLUSIONS: Compared to cMRI, LVivoEF can accurately quantify LVEF from a standard apical four-chamber view without manual correction. Thus, LVivoEF has the ability to improve and expedite LVEF quantification.


Assuntos
Inteligência Artificial , Função Ventricular Esquerda , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Software , Volume Sistólico
8.
JACC Cardiovasc Imaging ; 15(1): 108-120, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34274283

RESUMO

OBJECTIVES: This study investigated whether pulmonary artery (PA) 18F-FDG uptake is associated with hypertension, and if it correlates to elevated pulmonary pressures. BACKGROUND: 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) combined with computed tomography or cardiac magnetic resonance (CMR) has been used to assess inflammation mostly in large arteries of the systemic circulation. Much less is known about inflammation of the vasculature of the pulmonary system and its relationship to pulmonary hypertension (PH). METHODS: In a single-center cohort of 175 patients with suspected cardiac sarcoidosis, who underwent hybrid thoracic PET/CMR, 18F-FDG uptake in the PA was quantified according to maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR) and compared with available results from right heart catheterization (RHC) or transthoracic echocardiography (TTE). RESULTS: Thirty-three subjects demonstrated clear 18F-FDG uptake in the PA wall. In the subgroup of patients who underwent RHC (n = 10), the mean PA pressure was significantly higher in the group with PA 18F-FDG uptake compared with the group without uptake (34.4 ± 7.2 mm Hg vs 25.6 ± 9.3 mm Hg; P = 0.003), and 9 (90%) patients with PA 18F-FDG uptake had PH when a mean PA pressure cutoff of 25 mm Hg was used compared with 18 (45%) in the nonuptake group (P < 0.05). In the subgroup that underwent TTE, signs of PH were present in a significantly higher number of patients with PA 18F-FDG uptake (14 [51.9%] vs 37 [29.8%]; P < 0.05). Qualitative assessment of 18F-FDG uptake in the PA wall showed a sensitivity of 33% and specificity of 96% for separating patients with PH based on RHC-derived PA pressures. SUVmax and TBR in the PA wall correlated with PA pressure derived from RHC and/or TTE. CONCLUSIONS: We demonstrate that 18F-FDG uptake by PET/CMR in the PA is associated with PH and that its intensity correlates with PA pressure.


Assuntos
Hipertensão Pulmonar , Sarcoidose , Fluordesoxiglucose F18 , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Espectroscopia de Ressonância Magnética , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Artéria Pulmonar , Compostos Radiofarmacêuticos , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Sarcoidose/patologia
9.
Int J Cardiol ; 346: 100-102, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34798211

RESUMO

BACKGROUND: There are currently no clear guidelines regarding the use of ultrasound enhancing agents (UEAs) with transthoracic echocardiography (TTE) for patients hospitalized with Covid-19. We investigated whether the performance of TTE with UEAs provides more diagnostic information and allows for shorter acquisition time compared to unenhanced TTE imaging in this patient population. METHODS: We analyzed the TTEs of 107 hospitalized Covid-19 patients between April and June 2020 who were administered UEAs (Definity®, Lantheus). The time to acquire images with and without UEAs was calculated. A level III echocardiographer determined if new, clinically significant findings were visualized with the addition of UEAs. RESULTS: There was a mean of 11.84±3.59 UEA cineloops/study vs 20.74±8.10 non-UEA cineloops/study (p < 0.0001). Mean time to acquire UEA cineloop images was 72.28±28.18 s/study compared to 188.07±86.04 s/study for non-UEA cineloop images (p < 0.0001). Forty-eight patients (45%) had at least one new finding on UEA imaging, with a total of 62 new findings seen. New information gained with UEAs was more likely to be found in patients with acute respiratory distress syndrome (21 vs 9, p < 0.001) and in those on mechanical ventilation (21 vs 15, p = 0.046). CONCLUSIONS: TTE with UEAs required less time and fewer cineloop images compared to non-UEA imaging in patients hospitalized with Covid-19. Additionally, Covid-19 patients with severe respiratory disease benefited most with regard to new diagnostic information. Health care personnel should consider early use of UEAs in select hospitalized Covid-19 patients in order to reduce exposure and optimize diagnostic yield.


Assuntos
COVID-19 , Ecocardiografia , Humanos , SARS-CoV-2 , Ultrassonografia
11.
Pediatr Res ; 89(4): 869-877, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33038871

RESUMO

BACKGROUND: Previous studies describe a short-term decrease in cerebral oxygen saturation (StO2) after intraventricular hemorrhage (IVH) in premature infants; little is known about long-term implications. METHODS: Infants born <30 weeks gestational age (GA) were included. Clinical characteristics, hemoglobin measurements, the highest grade of IVH, and white matter injury (WMI) were noted. NIRS monitoring occurred daily or every other day for 4 weeks; weekly through 36 weeks GA. Recordings were error-corrected before calculation of mean StO2 and fractional tissue oxygen extraction (FTOE). Mean StO2 and FTOE were plotted by postnatal age and injury group (IVH/no IVH; WMI/no WMI). Non-linear regression by locally estimated scatterplot smoothing was used to generate the best-fit line and CI. RESULTS: A total of 1237 recordings from 185 infants were included; mean length = 6.5 h; mean GA = 26.3 w; mean BW = 951 g; overall/severe IVH incidence was 29/8%, WMI incidence was 16%. IVH was independently associated with an acute drop in StO2, which remained lower for 68 d. Severe IVH was associated with lower StO2 values than mild IVH. WMI was associated with early and persistent elevation of FTOE. CONCLUSION: IVH of any grade is associated with a prolonged cerebral desaturation and WMI is associated with prolonged elevation of FTOE. This finding is exacerbated for infants with severe IVH. IMPACT: The longitudinal impact of IVH on cerebral oxygenation has not been previously studied. IVH is associated with persistent cerebral desaturation, months in length, and is independent of anemia. More severe IVH is associated with worsened cerebral hypoxia. Infants later diagnosed with white matter injury have an early and persistent elevation of cerebral oxygen extraction (cFTOE). This cerebral desaturation, below previously identified normative ranges, may provide insight into the mechanistic link between IVH and white matter injury.


Assuntos
Hemorragia Cerebral/diagnóstico , Circulação Cerebrovascular , Doenças do Prematuro/diagnóstico , Oxigênio/sangue , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Hemorragia Cerebral/complicações , Hemorragia Cerebral/fisiopatologia , Feminino , Idade Gestacional , Hemoglobinas/metabolismo , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Neuroimagem , Oxigênio/metabolismo , Saturação de Oxigênio , Análise de Regressão , Substância Branca/fisiopatologia
12.
Methodist Debakey Cardiovasc J ; 16(3): 245-248, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33133362

RESUMO

Brugada electrocardiographic pattern, or Brugada phenocopy (BrP), can be found in conditions other than Brugada syndrome. We present the case of a 34-year-old woman who was found convulsing at home followed by ventricular tachycardia (VT) cardiac arrest upon arrival to the emergency department. Electrical direct cardioversion led to a return of spontaneous circulation, and she was started on intravenous amiodarone. The patient had four additional episodes of pulseless VT that returned to sinus rhythm with electrical cardioversion. A subsequent electrocardiogram taken in sinus rhythm revealed a right bundle branch block pattern with a coved ST segment elevation and inverted T waves in leads V1 and V2, suggestive of BrP type 1. Further inquiry revealed that an empty bottle of nortriptyline was found at her home. Nortriptyline intoxication was subsequently confirmed by a serum level of 1581 ng/mL. Treatments with intravenous sodium bicarbonate resolved the BrP, and she fully recovered with supportive care. Intoxication with drugs that inhibit cardiac sodium channels, such as nortriptyline, can trigger a BrP in otherwise normal individuals. Nortriptyline and other tricyclic antidepressants (TCAs) are used to treat chronic pain, depression, and other conditions but have dose-related side effects and can lead to fatal overdose. Intoxication by these TCAs should be on the differential when a BrP is observed.


Assuntos
Antidepressivos Tricíclicos/intoxicação , Síndrome de Brugada/diagnóstico , Overdose de Drogas , Eletrocardiografia , Nortriptilina/efeitos adversos , Taquicardia Ventricular/induzido quimicamente , Adulto , Síndrome de Brugada/fisiopatologia , Diagnóstico Diferencial , Feminino , Humanos , Valor Preditivo dos Testes , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia
13.
JAMA Cardiol ; 5(9): 1000-1005, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32936270

RESUMO

Importance: Myocardial replacement fibrosis has been reported to occur in one-third of patients with mitral valve prolapse (MVP) and significant mitral regurgitation (MR). However, it remains unknown whether there are detectable changes in myocardial metabolism suggestive of inflammation or ischemia that accompany the development of fibrosis. Objectives: To characterize the burden and distribution of fluorine 18-labeled (18F) fluorodeoxyglucose (FDG) uptake and late gadolinium enhancement (LGE) in patients with degenerative MVP and ventricular ectopy. Design, Setting, and Participants: Prospective observational study of 20 patients with MVP and significant primary degenerative MR who were referred for mitral valve repair and underwent hybrid positron emission tomography/magnetic resonance imaging (PET/MRI). Ventricular arrhythmias were categorized as either complex (n = 12) or minor (n = 8). Coregistered hybrid 18F FDG-PET and MRI LGE images were assessed and categorized. Recruitment occurred in the new patient clinic of a mitral valve repair reference center. This study was conducted from January 11, 2018, to June 26, 2019. Exposures: Simultaneous cardiac 18F FDG-PET and MRI with LGE imaging on a hybrid PET/MRI system and ambulatory rhythm monitoring. Main Outcomes and Measures: Patients were categorized by the presence and pattern of FDG uptake and LGE, the severity of ventricular arrhythmias, and the indication for mitral valve surgery. Results: In the cohort of 20 patients, the median age was 59.5 years (interquartile range, 52.5-63.2 years). Focal, or focal-on-diffuse uptake, of 18F-FDG (PET positive) was detected in 17 of 20 patients (85%). The FDG uptake coexisted with areas of LGE (PET/MRI positive) in 14 patients (70%). Of the 5 asymptomatic patients with normal ventricular indices and absence of any surgical indications, all were PET/MRI positive. Conclusions and Relevance: In this pilot study, we demonstrate a novel association between degenerative MVP and FDG uptake, a surrogate for myocardial inflammation and/or ischemia. Such evidence of myocardial injury, even in asymptomatic patients, suggests an ongoing subclinical disease process. These findings warrant further investigation into whether imaging for myocardial inflammation, ischemia, and scar has a role in arrhythmic risk stratification and whether it provides incremental prognostic value in patients with chronic severe mitral regurgitation undergoing active surveillance.


Assuntos
Arritmias Cardíacas/etiologia , Imagem Cinética por Ressonância Magnética/métodos , Prolapso da Valva Mitral/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Arritmias Cardíacas/diagnóstico , Feminino , Fluordesoxiglucose F18/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/complicações , Projetos Piloto , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacologia , Reprodutibilidade dos Testes
14.
Comput Methods Programs Biomed ; 196: 105716, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32858282

RESUMO

BACKGROUND: Limited-channel EEG research in neonates is hindered by lack of open, accessible analytic tools. To overcome this limitation, we have created the Washington University-Neonatal EEG Analysis Toolbox (WU-NEAT), containing two of the most commonly used tools, provided in an open-source, clinically-validated package running within MATLAB. METHODS: The first algorithm is the amplitude-integrated EEG (aEEG), which is generated by filtering, rectifying and time-compressing the original EEG recording, with subsequent semi-logarithmic display. The second algorithm is the spectral edge frequency (SEF), calculated as the critical frequency below which a user-defined proportion of the EEG spectral power is located. The aEEG algorithm was validated by three experienced reviewers. Reviewers evaluated aEEG recordings of fourteen preterm/term infants, displayed twice in random order, once using a reference algorithm and again using the WU-NEAT aEEG algorithm. Using standard methodology, reviewers assigned a background pattern classification. Inter/intra-rater reliability was assessed. For the SEF, calculations were made using the same fourteen recordings, first with the reference and then with the WU-NEAT algorithm. Results were compared using Pearson's correlation coefficient. RESULTS: For the aEEG algorithm, intra- and inter-rater reliability was 100% and 98%, respectively. For the SEF, the mean±SD Pearson correlation coefficient between algorithms was 0.96±0.04. CONCLUSION: We have demonstrated a clinically-validated toolbox for generating the aEEG as well as calculating the SEF from EEG data. Open-source access will enable widespread use of common analytic algorithms which are device-independent and unlikely to become outdated as technology changes, thereby facilitating future collaborative research in neonatal EEG.


Assuntos
Eletroencefalografia , Universidades , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Reprodutibilidade dos Testes , Washington
15.
J Addict Med ; 14(2): 113-118, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31149915

RESUMO

OBJECTIVES: To study the impact of sociodemographic factors on length of stay (LOS) for infants with neonatal opioid withdrawal syndrome (NOWS) secondary to fetal opioid exposure. METHODS: In this retrospective cohort study, we included term infants with NOWS, excluding those with other significant medical issues. Comprehensive clinical and sociodemographic data were collected. Multivariate regression modeling was used to identify factors which contributed to excess LOS, which was defined as the number of days beyond the standard monitoring and/or treatment protocol. RESULTS: In all, 129 infants were identified; mean gestational age of 37.9 ±â€Š1.3 weeks and mean body weight of 2880 ±â€Š496 g. Among them, 68% of infants were exposed to opioids; 27% were exposed to methadone; and 67% required pharmacologic treatment. The degree of poverty was assessed using the Area Deprivation Index (ADI) based on the mother's address at the time of birth. Median LOS for treated infants was 23 days versus 8 days for those who did not need pharmacologic treatment. The median excess LOS was 4 days (range 0-24).Excess hospital days were strongly correlated with degree of deprivation in the mother's community (r = 0.55, P < 0.01). ADI remained a strong predictor of excess LOS, even when controlling for pharmacologic treatment, placement in state's custody, race, and gestational age at birth. CONCLUSIONS: These results suggest poverty is associated with excess LOS and that early allocation of resources for at-risk families may help to reduce overall length of hospital stay.


Assuntos
Tempo de Internação/estatística & dados numéricos , Mães/estatística & dados numéricos , Síndrome de Abstinência Neonatal/epidemiologia , Pobreza/estatística & dados numéricos , Adulto , Analgésicos Opioides/uso terapêutico , Feminino , Humanos , Recém-Nascido , Masculino , Síndrome de Abstinência Neonatal/tratamento farmacológico , Estudos Retrospectivos
16.
World J Cardiol ; 11(3): 94-102, 2019 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-31040932

RESUMO

BACKGROUND: Left ventricular hypertrophy (LVH) is a common manifestation of cardiovascular disease and a risk factor for cardiovascular morbidity and mortality, but available methods for its electrocardiographic (ECG) diagnosis have limited accuracy. AIM: To investigate findings associated with LVH on ECG and developed an improved system for the diagnosis of LVH. METHODS: A cohort study comparing ECG data acquired within 30 days of transthoracic echocardiography (TTE) was performed. Multivariate regression analysis identified ECG findings associated with increased LV mass and mass index. A scoring system was derived and performance compared to established criteria for LVH. RESULTS: Data from 5486 outpatients with TTEs and corresponding ECGs were included in the derivation cohort, 333 (6.1%) of whom had LVH by TTE. In the primary regression analysis, findings associated with LVH were amplitudes of Q in V3, R in V6, S in V3, T in V6, P' in V1, P in V6, as well as R and T-axis discordance, R peak time in V6, QRS duration, weight, height, sex, and age. From this we derived a score consisting of 5 criteria, and validated it in an independent cohort of 910 patients. With a threshold of 1.5 points, sensitivity and specificity were 67.9% and 81.4%, and 62.5% and 83.2% in the derivation and validation cohorts, respectively. With a threshold of 2 points, sensitivity and specificity were 42.3% and 93.0%, and 37.5% and 93.4% in these cohorts. CONCLUSIONS: This score had superior sensitivity for detection of LVH by ECG while making a modest sacrifice in specificity compared to conventional criteria.

17.
J Appl Physiol (1985) ; 127(1): 103-110, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31046516

RESUMO

Delayed cord clamping (DCC) improves neurologic outcomes in preterm infants through a reduction in intraventricular hemorrhage (IVH) incidence. The mechanism behind this neuroprotective effect is not known. Infants born <28 wk gestation were recruited for longitudinal monitoring. All infants underwent 72 h of synchronized near-infrared spectroscopy (NIRS) and mean arterial blood pressure (MABP) recording within 24 h of birth. Infants with DCC were compared with control infants with immediate cord clamping (ICC), controlling for severity of illness [clinical risk index for babies (CRIB-II) score], chorioamnionitis, antenatal steroids, sedation, inotropes, and delivery mode. Autoregulatory dampening was calculated as the transfer function gain coefficient between the MABP and NIRS signals. Forty-five infants were included (DCC; n = 15, paired 2:1 with ICC controls n = 30). ICC and DCC groups were similar including gestational age (25.5 vs. 25.2 wk, P = 0.48), birth weight (852.3 vs. 816.6 g, P = 0.73), percent female (40 vs. 40%, P = 0.75), and dopamine usage (27 vs. 23%, P = 1.00). There was a significant difference in IVH incidence between the DCC and ICC groups (20 vs. 50%, P = 0.04). Mean MABP was not different (35.9 vs. 35.1 mmHg, P = 0.44). Compared with the DCC group, the ICC group had diminished autoregulatory dampening capacity (-12.96 vs. -15.06 dB, P = 0.01), which remained significant when controlling for confounders. Dampening capacity was, in turn, strongly associated with decreased risk of IVH (odds ratio = 0.14, P < 0.01). The results of this pilot study demonstrate that DCC is associated with improved dynamic cerebral autoregulatory function and may be the mechanism behind the decreased incidence of IVH. NEW & NOTEWORTHY The neuroprotective mechanism of delayed cord clamping in premature infants is unclear. Delayed cord clamping was associated with improved cerebral autoregulatory function and a marked decrease in intraventricular hemorrhage (IVH). Improved dynamic cerebral autoregulation may decrease arterial baroreceptor sensitivity, thereby reducing the risk of IVH.


Assuntos
Encéfalo/fisiopatologia , Hemorragia Cerebral/fisiopatologia , Homeostase/fisiologia , Recém-Nascido Prematuro/fisiologia , Pressão Arterial/fisiologia , Peso ao Nascer/fisiologia , Constrição , Feminino , Idade Gestacional , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Projetos Piloto , Gravidez , Fatores de Tempo , Cordão Umbilical/fisiologia
18.
Am J Perinatol ; 36(13): 1337-1343, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30609430

RESUMO

OBJECTIVE: To review developmental outcomes of neonates with mild hypoxic-ischemic encephalopathy (HIE) treated with therapeutic hypothermia (TH). STUDY DESIGN: Neonates ≥35 weeks' gestation with mild HIE/TH (TH group, n = 30) were matched with healthy term-born infants (control group, n = 30) and reviewed for the presence and severity of magnetic resonance imaging (MRI)-detected neurological injury. Neurodevelopmental outcomes were assessed using the Bayley Scales of Infant Development (BSID). RESULTS: MRI injury was present in 13/30 (43.3%) neonates (11 mild, 1 moderate, and 1 severe injuries) in the TH group. The mean (standard deviation [SD]) corrected age at BSID III was 29.3 (3.9) months in the controls compared with 14.7 (3.9) months in the TH group (p < 0.01). The mean (SD) cognitive, language, and motor composite scores in neonates in the TH group (n = 16, 53.3%) and control groups (n = 30, 100%) were 99.4 (17.1) versus 93.0 (12.3), (p = 0.15), 89.5 (15.5) versus 100.2 (18.4), (p = 0.054), and 93.1 (15.4) versus 100.8 (16.3) (p = 0.13), respectively. CONCLUSION: Developmental outcomes of neonates with mild HIE/TH were similar to healthy, term-born neonates.


Assuntos
Encéfalo/patologia , Desenvolvimento Infantil , Disfunção Cognitiva/etiologia , Hipotermia Induzida , Hipóxia-Isquemia Encefálica/complicações , Transtornos do Desenvolvimento da Linguagem/etiologia , Transtornos das Habilidades Motoras/etiologia , Encéfalo/diagnóstico por imagem , Estudos de Casos e Controles , Eletroencefalografia , Feminino , Humanos , Hipóxia-Isquemia Encefálica/fisiopatologia , Hipóxia-Isquemia Encefálica/terapia , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino , Índice de Gravidade de Doença
19.
J Perinatol ; 39(3): 393-400, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30459388

RESUMO

OBJECTIVE: To evaluate the association between early (within 10 d) pRBC transfusion and the development of severe ROP. STUDY DESIGN AND METHODS: This was a single-center retrospective study. Inclusion criteria were preterm infants born ≤32 weeks gestation or weighing ≤1500 g. Severe ROP was defined as infants requiring retinal laser ablation or bevacizumab injection. Logistic regression was used to identify the association between transfusions and severe ROP. RESULTS: A total of 1635 infants were included in the final analysis. The severe ROP incidence was 8% (126/1635). Ninety-one percent (115/126) of infants who developed severe ROP received a pRBC transfusion in the first 10 d. Early transfusion was associated with severe ROP; adjusted odds ratio of 3.8 (95% CI: 1.8-8.1). CONCLUSION: pRBC transfusions in the first 10 days of life are associated with an almost four-fold increased risk of severe ROP, independent of gestational age at birth or bronchopulmonary dysplasia (BPD) status.


Assuntos
Transfusão de Eritrócitos/efeitos adversos , Recém-Nascido Prematuro , Retinopatia da Prematuridade/epidemiologia , Retinopatia da Prematuridade/etiologia , Displasia Broncopulmonar/complicações , Feminino , Idade Gestacional , Humanos , Incidência , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Modelos Logísticos , Masculino , Missouri/epidemiologia , Estudos Retrospectivos , Fatores de Risco
20.
J Am Coll Cardiol ; 72(23 Pt A): 2904-2914, 2018 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-30522653

RESUMO

There is an increasing awareness of the association between mitral valve prolapse and sudden cardiac death. There are several clinical risk factors associated with an increased risk of mitral valve prolapse-related sudden cardiac death, most of which can be evaluated with noninvasive diagnostic modalities. For example, characteristic changes on the electrocardiogram (T-wave inversions in the inferior leads), complex ventricular ectopy, a spiked configuration of the lateral annular velocities by echocardiography, and evidence of myocardial fibrosis by cardiac magnetic resonance imaging have all been implicated as markers of risk. Herein, the authors review the reported incidence of sudden death to mitral valve prolapse, the clinical profile of at-risk patients, and the basic components necessary to initiate and perpetuate ventricular arrhythmias (substrate and trigger) as well as potential interventions to consider for those at highest risk.


Assuntos
Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Prolapso da Valva Mitral/epidemiologia , Prolapso da Valva Mitral/terapia , Arritmias Cardíacas/fisiopatologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/tendências , Eletrocardiografia/tendências , Humanos , Prolapso da Valva Mitral/fisiopatologia , Estudos Prospectivos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...