Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biofouling ; : 1-18, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39373126

RESUMO

To reveal the responsible microorganisms of microbiologically-influenced-corrosion (MIC), using 16S rRNA and ITS sequencing techniques, we investigated the bacterial and fungal communities in rust layer and seawater. Results show that the corrosion-related genera of Erythrobacter, norank_f__Rhodothermaceae, and Acinetobacter bacteria, as well as Aspergillus fungi, were overrepresented in the rust layer, along with the Pseudoalteromonas and Marinobacterium bacteria in seawater, and Ramlibacter, Aquimarina, and Williamsia bacteria were first detected in the rust layer. SourceTracker analysis revealed that approximately 23.08% of bacteria and 21.48% of fungi originated from seawater. Stochastic processes governed the rust layer and seawater microbial communities, and network analysis showed coexistence and interaction among bacterial and fungal communities. These results indicate that the composition of microbial communities in the rust layer was influenced by the marine environmental microbial communities, which can provide basic data support for the control of MIC in marine-related projects.

2.
Mikrochim Acta ; 188(8): 247, 2021 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-34244909

RESUMO

N-doped carbon dots (N-CDs) were fabricated in a simple procedure by hydrothermal treatment of cellobiose and urea. When excited at 235 nm or 327 nm, only one emission peak at around 420 nm has been observed. With the addition of phosalone, the excitation band at 235 nm was efficiently quenched within 1 min, while the excitation band at 327 nm showed little change. Accordingly, the fluorescence of the N-CDs-phosalone mixture showed quenching under 254-nm UV light, while nearly no fluorescence quenching could be observed under 365-nm UV light. This phenomenon provides a novel anti-false-positive mechanism for phosalone identification. Therefore, the label-free ratiometric sensor for rapid, naked-eye, and anti-false-positive detection of phosalone was proposed for the first time based on the intrinsic dual-excitation N-CDs. Under the optimum experimental conditions, the linear ranges of the excitation-based ratiometric assay were 0.08~4.0 µg/mL and 4.0~14.0 µg/mL; the limit of detection was 28.5 ng/mL. The as-constructed sensor was applied to detect phosalone residue in actual samples, and results were compared with the standard gas chromatographic (GC) method. The recoveries of the established sensor were between 90.0% and 110.0% with RSD lower than 6.6%, while that for the GC method was between 92.5% and 113.0% with RSD lower than 5.8%. Results reveal that the accuracy (recovery) and precision (RSD) of the as-constructed method are comparable to the standard GC method. In this paper, dual-excitation N-doped carbon dots (N-CDs) were synthesized by a simply one-step hydrothermal method for the first time. The novel dual-excitation ratiometric sensor based on the sole intrinsic N-CDs was constructed for phosalone sensing.


Assuntos
Transferência Ressonante de Energia de Fluorescência/métodos , Corantes Fluorescentes/química , Compostos Organotiofosforados/análise , Resíduos de Praguicidas/análise , Pontos Quânticos/química , Artocarpus/química , Cactaceae/química , Carbono/química , Contaminação de Alimentos/análise , Ipomoea/química , Limite de Detecção , Nitrogênio/química
3.
Food Chem ; 338: 127769, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-32862067

RESUMO

Illegal addition of melamine (MEL) to milk has caused serious food safety accident. It is urgent to develop a highly sensitive method for detecting MEL in milk. ß-Cyclodextrin with inner hydrophobic and outer hydrophilic cavities have been widely used in smart sensors design. In this study, an "ON-OFF-ON" sensor for MEL detection was constructed based on ß-cyclodextrin modified carbon nanoparticles (ß-CD-CNPs). The sensor is switched "OFF" when Fe3+ interacts with ß-CD-CNPs and switched "ON" when MEL replaces Fe3+. Fluorescence recovery of ß-CD-CNPs exhibits good linear correlations with MEL concentration ranging from 10.00 ng/mL ~ 180.00 ng/mL and 180.00 ~ 1000.00 ng/mL, the detection limit is 6.82 ng/mL. The sensor was applied to analysis melamine in milk samples with recovery between 94.80% ~ 102.05%, and RSD bellow 12.61%. The results show that this method can meet the requirements of real sample analysis.


Assuntos
Carbono/química , Análise de Alimentos/métodos , Leite/química , Nanopartículas/química , Triazinas/análise , Triazinas/química , beta-Ciclodextrinas/química , Animais , Contaminação de Alimentos/análise , Limite de Detecção , Espectrometria de Fluorescência
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 153: 268-72, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26318701

RESUMO

In this paper, we propose an "off-on" approach for the detection of sodium dodecyl-benzenesulfonate (SDBS) using carbon dots (CDs) as fluorescent probe. We firstly demonstrated that the fluorescence of CDs decreased apparently in the presence of ruthenium (Ru), and the system was thus "turn-off". The resulting CDs-Ru system was found to be sensitive to SDBS, SDBS not only serves to shelter the CDs effectively from being quenched, but also to reverse the quenching and restore the fluorescence due to its ability to remove Ru from the surface of CDs (turn-on). An eco-friendly, simple and sensitive platform for the detection of SDBS based on the CDs-Ru probes has been proposed. After the experimental conditions were optimized, the linear range for detection SDBS was 0.10-7.50 µg/mL, with correlation coefficient (r) 0.9988, detection limit was 0.033 µg/mL (3σ). This method is facile, rapid, low cost, environment-friendly, and possesses the potential for practical application.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(4): 1013-6, 2016 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-30048101

RESUMO

An new type of switch "On-Off" fluorescence probe was constructed based on fluorescence carbon dots as a novel strategy to analyze trace histidine(His) which was proposed for the first time. In water solution with pH 7.6, the fluorescence of CDs was quenched with Ru3+ due to the formation of ground state compound through electrostatic attraction, and the system was thus "turned-off". The fluorescence intensity of CDs was "turned-on" due to the competition between His and Ru towards the surface of CDs. The effect of critical parameters including pH, buffer solutions, reaction temperature and time needed to grow the fluorescence intensity of CDs was studied. Results show thatin water solution with pH 7.6, and when the temperature was between 20~25 ℃, the fluorescence intensity of the released CDs displayed a linear relationship in the range of (6.5~219.3)×10-6 mol·L-1 of captopril. Lower limit of detection for His, at the signal-to-noise ratio of 3/(3δ), was 2.15×10-6 mol·L-1. The methodology was successfully applied for the determination of His in Compound Amino Acid Injections, with the RSD≤2.07%, and the recovery rate was between 95.7%~102.4%. The result of the experiment was satisfactory. On the one hand, the excellent optical character CDs was acted as "On-Off" fluorescence probe, which could be extent the application of CDs, on the other hand, the excellent performance of the proposed fluorescence probe shows that this method possesses the potential for practical application.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 136 Pt C: 1328-34, 2015 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-25456675

RESUMO

In this paper, a fluorescence resonance energy transfer (FRET) system between fluorescence carbon dots (CDs, donor) and CdTe quantum dots (CdTe, acceptor) was constructed, and a novel platform for sensitive and selective determination of chlortoluron was accordingly proposed. It was found that in Tris-HCl buffer solution at pH=8.7, energy transfer from CDs to CdTe occurred, which resulted in a great enhancement of the fluorescence intensity of CdTe. Upon the addition of chlortoluron, in terms of strong interaction between chlortoluron and CdTe QDs through the formation of chlortoluron-CdTe ground state complex, resulted in CdTe fluorescence quenching. Under optimal conditions, in range of 2.4×10(-10)molL(-1)-8.5×10(-8)molL(-1), the change of CdTe fluorescence intensity was in good linear relationship with the chlortoluron concentration, and the detection limit was 7.8×10(-11)molL(-1) (S/N=3). Most of common relevant substance, cations and anions did not interfere with the detection of chlortoluron. The proposed method was applied to determine chlortoluron in water samples with satisfactory results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA