Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Invasive Cardiol ; 25(4): 190-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23549493

RESUMO

BACKGROUND: Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. METHODS: Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Medtronic CoreValve bioprosthesis. The smallest (D(min)) and largest (D(max)) orthogonal diameters in the basal ring of the aortic annulus were determined. We defined circularity of aortic annulus using the eccentricity index (1 - D(min)/D(max)). The primary endpoint was early occurrence of significant PAR, defined as > grade II PAR by postprocedural aortography. RESULTS: Eighty-four patients, mean age 83 ± 4 years with a mean aortic valve area of 0.7 ± 0.2 cm² were included. Twenty patients had postprocedural PAR > grade II. Using a receiver operating characteristic (ROC) analysis, eccentricity index correlated with significant PAR (AUC = 0.834; P=.034). A retrospectively determined eccentricity index cut-off of >0.25 was related to significant PAR with a sensitivity of 80%, specificity of 86%, and negative predictive value of 95% (P<.001). On univariate logistic regression, eccentricity index of >0.25 (P<.001) and device implantation depth (P=.015) correlated with significant PAR, while other parameters such as annular calcification and cover index did not. On multivariate analysis including only parameters with P<.1 on univariate analysis, eccentricity index >0.25 was the sole independent predictor of significant PAR. CONCLUSION: Eccentricity index is related to significant PAR after TAVI with Medtronic CoreValve. Further larger studies are required to determine the utility of this novel index in screening suitable patients for this procedure.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Bioprótese , Cateterismo Cardíaco/métodos , Anuloplastia da Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Tomografia Computadorizada Multidetectores , Análise Multivariada , Curva ROC , Estudos Retrospectivos
2.
Int J Cardiol ; 165(1): 61-6, 2013 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-21875755

RESUMO

INTRODUCTION: Microvascular obstruction (MVO) following ST-segment elevation myocardial infarction (STEMI) is associated with larger infarct size and an increased mortality. Although angiographic predictors of MVO in primary percutaneous coronary intervention (primary-PCI) setting have been identified, an earlier and objective "in-lab" predictor may be beneficial, in order to potentially influence therapies administered during primary-PCI. We hypothesised that intracoronary-electrocardiogram (IC-ECG) is a simple, objective and accurate predictor of MVO evaluated by cardiac magnetic resonance (CMR) and is comparable to myocardial blush grade (MBG) and TIMI myocardial perfusion grade (TMPG). METHOD: Intracoronary ECG was performed during primary-PCI. Intracoronary ST-segment measurement was performed before and immediately after opening of infarct-related-artery. Intracoronary ST-segment resolution (IC-STR) was defined as ≥ 1 mm improvement compared to baseline. Contrast enhanced CMR was performed at 4 and 90 days post primary-PCI. Primary endpoint was MVO on late gadolinium hyperenhancement assessed by CMR at day 4. RESULTS: Sixty-four consecutive patients (age 59 ± 11 years; 55 males) were recruited. Intracoronary ST-segment resolution correlated with MVO (p=0.005). Furthermore, IC-STR correlated with infarct-mass, non-viable-mass, peak creatinine kinase and end-systolic-volume at day 4. Intracoronary ST-segment resolution also correlated with favourable left ventricular end-diastolic-volume at day 90 (p=0.022). On multivariate analysis, IC-STR was an independent predictor of MVO. CONCLUSION: Intracoronary ST-segment resolution is a strong in-lab predictor of MVO assessed 4 days after STEMI on CMR. Furthermore, IC-STR correlates with infarct size and left ventricular remodelling at 3 months. Further studies are required to understand potential clinical utility of this tool.


Assuntos
Vasos Coronários/patologia , Eletrocardiografia/métodos , Microcirculação/fisiologia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/métodos , Idoso , Estudos de Coortes , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 80(5): 746-53, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22422674

RESUMO

BACKGROUND: ST-segment-resolution (STR) on surface electrocardiogram (ECG) is a good surrogate for myocardial reperfusion in patients with acute ST-segment-elevation-myocardial-infarction (STEMI). We sort to determine the optimal criteria of measuring STR on intracoronary-ECG (IC-ECG) for prediction of myocardial injury evaluated by cardiac MRI (CMR). METHODS: Measurements of IC-ECG ST-segments were performed at baseline, immediately after (early) and 15 min (late) after achieving TIMI-3 flow during primary-PCI. The degree of ST-segment-shift from baseline noted upon the IC-ECG was divided into four groups: (group 1) ST-segment-resolution >1 mm, (group 2) <30% resolution, (group 3) >50% resolution, (group 4) >70% resolution at both early and late time points. Patients had CMR at days 3 and 90 postprimary-PCI. RESULTS: Fifty two patients (aged 60 ± 11 years; 43 males) were evaluated. Early intracoronary-ECG ST-segment resolution (early IC-STR >1 mm) correlated with smaller scar mass (P = 0.003), nonviable myocardial mass (P < 0.001), and microvascular obstruction (MVO) (P = 0.004) on CMR at day 3. Ejection fraction (EF) was also better at day 3 (P = 0.026) and 90 (P = 0.039). Patients with poor early IC-STR (IC-STR <30%) conversely is associated with larger scar mass (P = 0.017), nonviable myocardial mass (P = 0.01), and MVO (P = 0.021) at day 3. This was also associated with worse EF at day 90 (P = 0.044). Neither group 3 or 4, or the late measurements of late IC-STR correlated with CMR markers of myocardial injury. CONCLUSION: The degree of early IC-STR (defined by IC-STR > 1 mm or <30%) successfully predicts myocardial damage following primary-PCI for an acute STEMI. Further studies are required to investigate its potential utility.


Assuntos
Angioplastia Coronária com Balão , Eletrocardiografia , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Circulação Coronária , Feminino , Humanos , Modelos Lineares , Masculino , Microcirculação , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Stents , Volume Sistólico , Fatores de Tempo , Sobrevivência de Tecidos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
4.
Med J Aust ; 196(4): 246-9, 2012 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-22409689

RESUMO

Computed tomography coronary angiography (CTCA) has been shown in multicentre trials to be reliable in ruling out significant coronary artery disease (CAD). It is used most appropriately in symptomatic patients with low to intermediate pretest probability of CAD. It should not be used in asymptomatic subjects, patients with known significant CAD or patients with a high pretest probability of CAD. The radiation dose of CTCA was previously two to three times that of invasive coronary angiography but with modern protocols, it is similar or lower. Patients generally need to be in sinus rhythm, tolerate Β-blockers and nitrates, have a heart rate < 65 beats per minute, be able to hold their breath for 10 seconds, and have normal renal function.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Procedimentos Desnecessários/estatística & dados numéricos , Austrália , Feminino , Humanos , Incidência , Masculino , Guias de Prática Clínica como Assunto , Medição de Risco
5.
Int J Cardiovasc Imaging ; 28(8): 2091-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22318541

RESUMO

Accurate assessment of aortic annular dimensions is essential for successful transcatheter aortic valve implantation (TAVI). Annular dimensions are conventionally measured in mid-systole by multidetector computed tomography (MDCT), echocardiography and angiography. Significant differences in systolic and diastolic aortic annular dimensions have been demonstrated in cohorts without aortic stenosis (AS), but it is unknown whether similar dynamic variation in annular dimensions exists in patients with severe calcific AS in whom aortic compliance is likely to be substantially reduced. We investigated the variation in aortic annular dimensions between systole and diastole in patients with severe calcific AS. Patients with severe calcific AS referred for TAVI were evaluated by 128-slice MDCT. Aortic annular diameter was measured during diastole and systole in the modified coronal, modified sagittal, and basal ring planes (maximal, minimal and mean diameters). Differences between systole and diastole were analysed by paired t test. Fifty-nine patients were included in the analysis. Three of the five aortic dimensions measured increased significantly during systole. The largest change was a 0.75 mm (3.4%) mean increase in the minimal diameter of the basal ring during systole (p = 0.004). This corresponds closely to the modified sagittal view, which also increased by mean 0.42 mm (1.9%) during systole (p = 0.008). There was no significant change in the maximal diameter of the basal ring or the modified coronal view during systole (p > 0.05). There is a small magnitude but statistically significant difference in aortic annulus dimensions of patients with severe AS referred for TAVI when measured in diastole and systole. This small difference is unlikely to alter clinical decisions regarding prosthesis size or suitability for TAVI.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Calcinose/terapia , Cateterismo Cardíaco , Diástole , Implante de Prótese de Valva Cardíaca/métodos , Tomografia Computadorizada Multidetectores , Sístole , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
Eur Heart J ; 33(4): 495-504, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21951627

RESUMO

AIMS: The interaction between coronary ß(2)-adrenoreceptors and segmental plaque burden is complex and poorly understood in humans. We aimed to validate intracoronary (IC) salbutamol as a novel endothelium-dependent vasodilator utilizing intravascular ultrasound (IVUS), and thus assess relationships between coronary ß(2)-adrenoreceptors, regional plaque burden and segmental endothelial function. METHODS AND RESULTS: In 29 patients with near-normal coronary angiograms, IVUS-upon-Doppler Flowire imaging protocols were performed. Protocol 1: incremental IC salbutamol (0.15, 0.30, 0.60 µg/min) infusions (15 patients, 103 segments); protocol 2: salbutamol (0.30 µg/min) infusion before and after IC administration of N(G)-monomethyl-L-arginine (L-NMMA) (10 patients, 82 segments). Vehicle infusions (IC dextrose) were performed in 4 patients (21 segments). Macrovascular response [% change segmental lumen volume (ΔSLV)] and plaque burden [per cent atheroma volume (PAV)] were studied in 5-mm coronary segments. Microvascular response [per cent change in coronary blood flow (ΔCBF)] was calculated following each infusion. Intracoronary salbutamol demonstrated significant dose-response ΔSLV and ΔCBF from baseline, respectively (0.15 µg/min: 3.5 ± 1.3%, 28 ± 14%, P = 0.04, P = NS; 0.30 µg/min: 5.5 ± 1.4%, 54 ± 17%, P = 0.001, P < 0.0001; 0.60 µg/min: 4.8 ± 1.6%, 66 ± 15%, P = 0.02, P < 0.0001), with ΔSLV responses further exemplified in low vs. high plaque burden groups. Salbutamol vasomotor responses were suppressed by l-NMMA, supporting nitric oxide-dependent mechanisms. Vehicle infusions resulted in no significant ΔSLV or ΔCBF. Multivariate analysis including conventional cardiovascular risk factors, PAV, segmental remodelling and plaque eccentricity indices identified PAV as the only significant predictor of a ΔSLV to IC salbutamol (coefficient -0.18, 95% CI -0.32 to -0.044, P = 0.015). Conclusions Intracoronary salbutamol is a novel endothelium-dependent epicardial and microvascular coronary vasodilator. Intravascular ultrasound-derived regional plaque burden is a major determinant of segmental coronary endothelial function.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2/farmacologia , Albuterol/farmacologia , Endotélio Vascular/efeitos dos fármacos , Receptores Adrenérgicos beta 2/fisiologia , Vasodilatadores/farmacologia , Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Agonistas de Receptores Adrenérgicos beta 2/efeitos adversos , Albuterol/administração & dosagem , Albuterol/efeitos adversos , Circulação Coronária/efeitos dos fármacos , Relação Dose-Resposta a Droga , Endotélio Vascular/fisiologia , Feminino , Humanos , Masculino , Microcirculação/efeitos dos fármacos , Angina Microvascular/etiologia , Angina Microvascular/fisiopatologia , Pessoa de Meia-Idade , Óxido Nítrico/fisiologia , Variações Dependentes do Observador , Placa Aterosclerótica/fisiopatologia , Receptores Adrenérgicos beta 2/efeitos dos fármacos , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/métodos , Vasodilatadores/administração & dosagem , Vasodilatadores/efeitos adversos , ômega-N-Metilarginina/farmacologia
8.
J Cardiovasc Magn Reson ; 13: 62, 2011 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-22017888

RESUMO

BACKGROUND: Adenosine stress cardiovascular magnetic resonance (CMR) has been proven an effective tool in detection of reversible ischemia. Limited evidence is available regarding its accuracy in the setting of acute coronary syndromes, particularly in evaluating the significance of non-culprit vessel ischaemia. Adenosine stress CMR and recent advances in semi-quantitative image analysis may prove effective in this area. We sought to determine the diagnostic accuracy of semi-quantitative versus visual assessment of adenosine stress CMR in detecting ischemia in non-culprit territory vessels early after primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). METHODS: Patients were prospectively enrolled in a CMR imaging protocol with rest and adenosine stress perfusion, viability and cardiac functional assessment 3 days after successful primary-PCI for STEMI. Three short axis slices each divided into 6 segments on first pass adenosine perfusion were visually and semi-quantitatively analysed. Diagnostic accuracy of both methods was compared with non-culprit territory vessels utilising quantitative coronary angiography (QCA) with significant stenosis defined as ≥ 70%. RESULTS: Fifty patients (age 59 ± 12 years) admitted with STEMI were evaluated. All subjects tolerated the adenosine stress CMR imaging protocol with no significant complications. The cohort consisted of 41% anterior and 59% non anterior infarctions. There were a total of 100 non-culprit territory vessels, identified on QCA. The diagnostic accuracy of semi-quantitative analysis was 96% with sensitivity of 99%, specificity of 67%, positive predictive value (PPV) of 97% and negative predictive value (NPV) of 86%. Visual analysis had a diagnostic accuracy of 93% with sensitivity of 96%, specificity of 50%, PPV of 97% and NPV of 43%. CONCLUSION: Adenosine stress CMR allows accurate detection of non-culprit territory stenosis in patients successfully treated with primary-PCI post STEMI. Semi-quantitative analysis may be required for improved accuracy. Larger studies are however required to demonstrate that early detection of non-culprit vessel ischemia in the post STEMI setting provides a meaningful test to guide clinical decision making and ultimately improved patient outcomes.


Assuntos
Adenosina , Angioplastia Coronária com Balão , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Imagem de Perfusão do Miocárdio/métodos , Vasodilatadores , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Circulação Coronária , Estenose Coronária/complicações , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/fisiopatologia , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Austrália do Sul , Fatores de Tempo , Resultado do Tratamento
10.
Int J Cardiovasc Imaging ; 25(3): 251-7, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18979182

RESUMO

We investigated the ability of fluorodeoxyglucose positron emission tomography (FDG PET) imaging to serially monitor macrophage content in a rabbit model of atherosclerosis. Atherosclerosis was induced in rabbits (n = 8) by a combination of atherogenic diet and balloon denudation of the aorta. At the end of nine months, the rabbits were randomized to a further six months of the same atherogenic diet (progression group) or normal diet (regression group). In vivo uptake of FDG by the thoracic aorta was measured using aortic uptake-to-blood radioactivity ratios at the start and end of the randomized period. A significant increase in FDG uptake of the progression group after continued cholesterol feeding (aortic uptake-to-blood radioactivity: 0.57 +/- 0.02 to 0.68 +/- 0.02, P = 0.001), and a corresponding fall in FDG uptake of the regression group after returning to a normal chow diet (aortic uptake-to-blood radioactivity ratios: 0.67 +/- 0.02 to 0.53 +/- 0.02, P < 0.0001). FDG PET can quantify in vivo macrophage content and serially monitor changes in FDG activity in this rabbit model.


Assuntos
Aterosclerose/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Animais , Aterosclerose/patologia , Dieta Aterogênica , Modelos Animais de Doenças , Progressão da Doença , Fluordesoxiglucose F18/farmacocinética , Coelhos , Interpretação de Imagem Radiográfica Assistida por Computador , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...