Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Perinatol ; 35(5): 357-61, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25357094

RESUMO

OBJECTIVE: Neonates with undiagnosed hereditary spherocytosis (HS) are at risk for developing hazardous hyperbilirubinemia and anemia. Making an early diagnosis of HS in a neonate can prompt anticipatory guidance to prevent these adverse outcomes. A recent comparison study showed that a relatively new diagnostic test for HS, eosin-5-maleimide (EMA)-flow cytometry, performs better than other available tests in confirming HS. However, reports have not specifically examined the performance of this test among neonates. STUDY DESIGN: We compared EMA-flow cytometry from blood samples of healthy control neonates vs samples from neonates suspected of having HS on the basis of severe Coombs-negative jaundice and spherocytes on blood film. The diagnosis of HS was later either confirmed or excluded based on clinical findings and next generation sequencing (NGS) after which we correlated the EMA-flow results with the diagnosis. RESULT: EMA-flow was performed on the blood of 31 neonates; 20 healthy term newborns and 11 who were suspected of having HS. Eight of the 11 were later confirmed positive for HS and one was confirmed positive for hereditary elliptocytosis (HE). All nine had persistently abnormal erythroid morphology, reticulocytosis and anemia, and eight of the nine had relevant mutations discovered using NGS. The other was confirmed positive for HS on the basis that a parent had HS, and the neonate's spherocytosis, reticulocytosis and anemia persisted. The 20 healthy controls and the 2 in whom HS was initially suspected but later excluded all had EMA-flow results in the range reported in healthy children and adults. In contrast, all nine in whom HS or HE was confirmed had abnormal EMA-flow results consistent with previous reports in older children and adults with HS. CONCLUSION: Although our sample size is small, our findings are consistent with the literature in older children and adults suggesting that EMA-flow cytometric testing performs well in supporting the diagnosis of HS/HE during the early neonatal period.


Assuntos
Amarelo de Eosina-(YS)/análogos & derivados , Triagem Neonatal , Esferocitose Hereditária/diagnóstico , Esferocitose Hereditária/genética , Estudos de Casos e Controles , Amarelo de Eosina-(YS)/análise , Citometria de Fluxo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Recém-Nascido , Esferócitos
2.
Cytometry ; 40(1): 32-41, 2000 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-10754515

RESUMO

BACKGROUND: Plasminogen activator inhibitor type 2 (PAI-2) is a member of the serine protease inhibitor (SERPIN) superfamily and forms stable complexes with urokinase type plasminogen activator (uPA). uPA can be found on the cell surface attached to its specific receptor (uPAR), allowing for controlled degradation of the extracellular matrix by the activation of plasminogen into plasmin. The aim of this study was to evaluate if PAI-2 could also be detected on the cell surface, providing a means of regulating the activity of cell surface uPA. METHODS: Intact or permeabilized cell lines or human peripheral blood leukocytes were assayed by flow cytometry for cell surface uPA or PAI-2. Plasma membrane-enriched preparations prepared from Jurkat, HaCaT, THP-1, U937, or MM6 cells were assayed by enzyme-linked immunosorbent assay (ELISA) or Western blotting for PAI-2 antigen. RESULTS: By flow cytometry, cell surface PAI-2 was not detected on monocytes from human peripheral blood, MM6, or HaCaT cells. Cell surface PAI-2 was only detected very weakly on the surface of U937 cells. In contrast, PAI-2 could be detected in all of these cells when fixed and permeabilized. By ELISA, PAI-2 was very abundant in the cytosol-enriched preparations of U937, MM6, and HaCaT cells, but was present in lower amounts in the plasma membrane-enriched preparations. By Western blotting, monomeric nonglycosylated PAI-2, but not uPA/PAI-2 complexes, could be detected in the cytosol and plasma membrane-enriched preparations. CONCLUSIONS: These results indicate that PAI-2 cannot be detected on the surface of PAI-2-expressing cells, and confirm that PAI-2 is predominantly a cytosolic protein.


Assuntos
Citometria de Fluxo/métodos , Inibidor 2 de Ativador de Plasminogênio/análise , Anticorpos Monoclonais , Western Blotting , Membrana Celular/química , Ensaio de Imunoadsorção Enzimática , Humanos , Técnicas Imunoenzimáticas , Imunoglobulina G , Monócitos/química , Monócitos/imunologia , Inibidor 2 de Ativador de Plasminogênio/imunologia , Células U937 , Ativador de Plasminogênio Tipo Uroquinase/análise , Ativador de Plasminogênio Tipo Uroquinase/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...