Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Dent ; 137: 104676, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37633483

RESUMO

PURPOSE: The objective of this study was to investigate the accuracies of three-dimensional (3D) facial scanning mobile phone applications as compared to professional 3D facial imaging systems. MATERIALS AND METHODS: A manikin head model was used as the subject for comparing six 3D facial imaging systems which comprised three professional 3D scanners (3dMDface, Artec Eva and Vectra H2) and three mobile phone applications (Bellus3D, ScandyPro and Hedges). For each system, five scans were taken to analyse (1) linear accuracy using 9 measurements (2) global and (3) regional 3D accuracy of the scanned surface by root mean square (RMS) and colour map analysis. Another set of five scans was repeated by a second operator to evaluate the inter-operator reproducibility for each system. RESULTS: All the facial imaging systems had absolute errors lesser than 1.0 mm for the linear measurements. The technical error of measurement (TEM) for inter-examiner and intra-examiner linear measurements were within acceptable limits. Artec Eva, Vectra H2 and Scandy Pro had poor global 3D trueness (RMS > 1.0 mm) but good 3D regional trueness (RMS < 1.0 mm). 3dMDface, Bellus3D Face App and Heges had good global and regional 3D trueness. All the facial imaging systems had good global and regional 3D precision and reproducibility (RMS < 1.0 mm). CONCLUSION: This study demonstrated that mobile phone 3D scanning applications had comparable trueness, precision and reproducibility to professional systems. Colour map analysis supplemented the use of the RMS value to demonstrate facial regions of significant deviation. Clinicians should also consider the specific area or region of inaccuracies for each system to determine whether the chosen system is appropriate for the clinical condition or procedure. CLINICAL SIGNIFICANCE: Mobile phone 3D facial imaging applications may be as accurate as 3D professional facial scanning systems for craniomaxillofacial purposes. However, the choice of the system may vary depending on the specific area of interest.


Assuntos
Telefone Celular , Aplicativos Móveis , Humanos , Projetos Piloto , Reprodutibilidade dos Testes , Suplementos Nutricionais
3.
BMC Oral Health ; 19(1): 138, 2019 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-31288794

RESUMO

BACKGROUND: Tumoral calcinosis is an uncommon clinicopathological condition which is characterized by the formation of calcium salt deposition in intra-articular or peri-articular soft tissues. It usually presents as a focal growth of hard tissue, either solitary or multiple, beneath the skin and connective tissue. Diagnostic techniques mainly include clinical and radiographic evaluation. The most commonly involved locations include the hip, elbow, shoulder and knee. Involvement of the head and neck regions are far less common. There have been 5 case reports of temporomandibular joint involvement in the literature so far. CASE PRESENTATION: We present a case report which describes the diagnosis and management of a 59 year old female patient with chronic right temporomandibular joint pain and localized bony hard swelling over the right pre-auricular region. Patient retained normal range of motion and mouth opening. Computed tomography taken showed a radio-opaque juxta-articular ovoid mass over the right pre-auricular region in close proximity but not fused to the mandibular condyle. Surgical excision was performed for this swelling via a pre-auricular approach under general anaesthesia. Histological examination performed confirmed the diagnosis of tumoral calcinosis. Pain at the right temporomandibular joint was resolved after the surgery. Serum calcium and phosphate levels were normal in this patient. CONCLUSION: Surgical excision is the primary treatment modality for tumoral calcinosis. Tumoral calcinosis may be associated with elevated serum calcium and phosphate levels. In patients with elevated serum electrolytes, it is important to consider the overall systemic health in management of this condition. Management of serum electrolytes levels plays a role in reducing recurrence rates. This case report and review aims to discuss the diagnosis, treatment and overall systemic management of this rare condition.


Assuntos
Calcinose , Articulação Temporomandibular , Edema , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...