Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Med Sci ; 346(3): 181-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23328836

RESUMO

Percutaneous patent foramen ovale (PFO) closure is a treatment for cryptogenic stroke and migraine headache. The goal of this study was to assess long-term outcomes of patients treated with percutaneous PFO closure. Records of patients with percutaneous PFO closure at Emory University Hospital from February 2002 to July 2009 were reviewed. Follow-up telephone questionnaire and chart review assessed recurrent stroke, migraine, and complications. Data was reviewed on 414 consecutive patients. Long-term follow-up was obtained in 207 of patients, and mean follow up was 4.6 ± 2.0 years. Cryptogenic stroke was the primary indication for intervention in 193 (93%) patients. Thirteen (7%) patients had a recurrent neurologic event post closure. In patients with multiple neurological events at baseline, 17% (n = 11) had a recurrent event, compared with 2% (n = 2) of patients with a single neurological event prior to PFO-closure (P < 0.002). Post closure, migraine frequency and severity declined from 4.5 to 1.1 migraine/month (P < 0.01) and 7.2 to 3.6 out of 10 (P < 0.01) in patients with history of migraine (n = 60). Thirty-day mortality was 1% (n = 2). One patient had device erosion 5 years post-procedure requiring emergent surgery. Atrial fibrillation was newly diagnosed in 8 (4%) patients within 6 months. In conclusion, the long-term rate of recurrent stroke after PFO closure is low in patients with a single neurological event at baseline. Serious long-term complications after PFO closure are rare. PFO closure may decrease the frequency and severity of migraine.


Assuntos
Forame Oval Patente/terapia , Ataque Isquêmico Transitório/prevenção & controle , Transtornos de Enxaqueca/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Adulto , Idoso , Cateterismo Cardíaco , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Secundária , Resultado do Tratamento
2.
Ann Thorac Surg ; 94(1): 275-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22734994

RESUMO

Patients who present with significant paravalvular regurgitation after mitral valve replacement remain a difficult patient population and high-risk surgical candidates. We present 3 cases of transapical closure of mitral valve paravalvular leak (PVL) after mitral valve replacement using Amplatzer closure devices (AGA Medical Corp, Plymouth, MN). All 3 patients experienced decreased regurgitation at the site of the closure as well as symptomatic improvement in their heart failure.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/cirurgia
3.
Am J Med Sci ; 343(6): 490-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22683616

RESUMO

Aortic stenosis (AS) is the most common valvular disease in the western world affecting mainly individuals older than 60 years. It is recognized as an indolent disease characterized by years to decades of slow progression followed by rapid clinical deterioration and high mortality once symptoms develop. Medical therapies for AS remain ineffective with surgical aortic valve replacement (AVR) remaining the only proven effective long-term treatment. The advancement in transcatheter AVR has revolutionized the treatment of inoperable severe AS and holds promise for future widespread use as more long-term experience is established. The authors review the natural history of AS presentation with a special emphasis on management of severe AS and advancement in transcatheter AVR.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Animais , Estenose da Valva Aórtica/epidemiologia , Cateterismo Cardíaco/métodos , Ensaios Clínicos como Assunto/métodos , Progressão da Doença , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Humanos
4.
Expert Rev Cardiovasc Ther ; 9(9): 1127-35, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21932955

RESUMO

Aortic stenosis is the most common cause for valvular surgery in the USA. For nearly 50 years, surgical aortic valve replacement has been the standard of care for symptomatic patients; unfortunately, a significant number of patients are not referred to surgery owing to advanced comorbidities and age. Transcatheter aortic valve replacement has emerged as an effective therapy for patients at high risk for surgery. Through device innovations and accumulated experience, the safety and efficacy of the procedure has improved since its inception. Transcatheter valve replacement has been found superior to medical therapy in inoperable patients with aortic stenosis, yet many questions remain as to which patients are appropriate for this exciting and novel therapy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Seleção de Pacientes , Fatores Etários , Cateterismo Cardíaco/métodos , Comorbidade , Humanos , Desenho de Prótese , Fatores de Risco , Estados Unidos
5.
JACC Cardiovasc Interv ; 3(1): 114-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20129579

RESUMO

OBJECTIVES: Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size. BACKGROUND: Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implantation. METHODS: Twenty-seven patients underwent sizing of the aortic annulus by BAV and TEE. We implanted the minimal THV size that was greater than the annulus measured by BAV. RESULTS: The annulus measured by TEE was 21.3 +/- 1.6 mm and by BAV was 22.6 +/- 1.8 mm (p < 0.001). The number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). Fourteen patients (52%) required upsizing of the initial balloon suggested by TEE; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). No change in aortic insufficiency or hemodynamic instability occurred with BAV. Fifteen patients (56%) received a 23-mm THV; 12 patients a 26-mm THV. No coronary occlusion, annular damage, or THV embolization occurred. Paravalvular leak was grade

Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco , Cateterismo , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo/instrumentação , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Desenho de Prótese , Resultado do Tratamento
6.
Obesity (Silver Spring) ; 17(4): 827-31, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19148115

RESUMO

Copper is an essential cofactor in many enzymatic reactions vital to the normal function of the hematologic, vascular, skeletal, antioxidant, and neurologic systems. Copper deficiency in the United States is believed to be relatively rare but has been described in the setting of zinc supplementation, myelodysplastic syndrome, use of parenteral nutrition and chronic tube feeding, and in various malabsorptive syndromes, including following gastrectomy and gastric bypass surgery. Features of copper deficiency include hematologic abnormalities (anemia, neutropenia, and leukopenia) and myeloneuropathy; the latter is a rarer and often unrecognized complication of copper deficiency. We here describe two patients who presented with severe gait abnormalities and anemia combined with neutropenia several years after roux-en-Y gastric bypass (RYGB) surgery for obesity who were found to be severely copper deficient. Intravenous copper repletion resulted in the rapid correction of hematologic indices; combined intravenous and oral copper supplementation and eventual oral copper supplements alone normalized serum copper levels in each patient, but resulted in only partial resolution of the neurologic deficits. This report serves to alert physicians of the association between RYGB procedures and subsequent copper deficiency in order to avoid diagnostic delays and to improve treatment outcomes.


Assuntos
Cobre/deficiência , Derivação Gástrica/efeitos adversos , Obesidade/cirurgia , Anemia/diagnóstico , Anemia/etiologia , Cobre/administração & dosagem , Cobre/uso terapêutico , Suplementos Nutricionais , Feminino , Transtornos Neurológicos da Marcha/diagnóstico , Transtornos Neurológicos da Marcha/etiologia , Humanos , Pessoa de Meia-Idade
7.
JACC Cardiovasc Interv ; 1(5): 580-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19463362

RESUMO

OBJECTIVES: We sought to study the potential role of balloon aortic valvuloplasty (BAV) in sizing the aortic annulus in patients before transcatheter heart valve (THV) implantation. BACKGROUND: Despite clinicians' growing experience with THV procedures, the best method of annulus sizing remains unclear. METHODS: Twenty-three patients with aortic stenosis (<1.0 cm(2)) who were undergoing surgical valve replacement were enrolled. Pre-operative echocardiographic measurements of the annulus and computed tomography measurements of valve calcium were made. Intraoperatively, a valvuloplasty balloon of known size and inflatable pressure was inserted into the aortic valve and inflated. The development of intraballoon pressure in addition to the nominal inflation pressure (AIBP) reflected the apposition of balloon and valve. Surgical annulus was measured by cylindrical sizers. RESULTS: In patients with tricuspid valves, AIBP was generated in 11 of 12 patients when the balloon diameter was greater than the surgically measured annulus, regardless of leaflet calcification (2 of 10 patients when balloon < or = surgical annulus). In bicuspid valves, high AIBP ( approximately 1 atm) was encountered with balloons that were within 1 mm of annulus size, and leaflet dehiscence occurred with larger balloons (n = 2 patients). Annulus size was underestimated by transthoracic echocardiogram and transesophageal echocardiogram compared with surgery (p < 0.001): transthoracic echocardiogram = 21.5 +/- 1.8 mm, transesophageal echocardiogram = 22.0 +/- 1.6 mm and surgical = 23.2 +/- 1.9 mm (range 20 to 27 mm, mode 22 mm). CONCLUSIONS: These data suggest that measuring AIBP during balloon aortic valvuloplasty in tricuspid valves is an important adjunctive measurement of the aortic annulus and may help in determining the appropriate THV size.


Assuntos
Estenose da Valva Aórtica/terapia , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico , Calcinose/cirurgia , California , Ecocardiografia Transesofagiana , Feminino , Georgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
J Am Soc Echocardiogr ; 20(5): 537.e7-8, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17484997

RESUMO

Cardiac nocardiosis is a rare disease that is nearly always associated with cardiac operation. We report the case of a patient with a 10-month history of intermittent fevers after coronary artery bypass operation who presented with progressive shortness of breath and fever. He was found to have a large aortic aneurysm secondary to Nocardia nova infection likely transmitted during his original bypass operation. This is the first reported case of Nocardia aortitis after coronary bypass operation and serves to alert physicians of this rare but serious postoperative complication.


Assuntos
Aortite/etiologia , Ponte de Artéria Coronária/efeitos adversos , Doença das Coronárias/cirurgia , Nocardiose/etiologia , Nocardia/isolamento & purificação , Infecção da Ferida Cirúrgica , Idoso , Aortite/diagnóstico por imagem , Aortite/microbiologia , Diagnóstico Diferencial , Ecocardiografia Transesofagiana/métodos , Humanos , Masculino , Nocardiose/diagnóstico por imagem , Nocardiose/microbiologia
9.
Am J Clin Pathol ; 127(2): 237-47, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17210529

RESUMO

We encountered 16 patients with connective tissue disease in whom pulmonary fibrosis developed. Routine light microscopic, ultrastructural, and direct immunofluorescent analyses were conducted, and circulating antibodies, including those of endothelial cell derivation, were assessed using indirect immuno-fluorescence and Western blot assays. Underlying diseases were dermatomyositis, scleroderma, mixed connective tissue disease, sclerodermatomyositis, Sjögren syndrome, rheumatoid arthritis, and anti-Ro-associated systemic lupus erythematosus. Antibodies to one or more Ro, RNP, Jo 1, OJ, and/or nucleolar antigens were seen in all cases and antiphospholipid antibodies in half. All biopsies revealed microvascular injury in concert with intraparenchymal fibrosis; in some cases, there were corroborative ultrastructural findings of microvascular injury. Patterns of fibroplasia represented nonspecific interstitial pneumonitis and usual interstitial pneumonitis. We noted IgG, IgA, and/or complement in the septal microvasculature. In 6 cases with available serum samples, indirect immunofluorescent endothelial cell antibody studies were positive and Western Blot studies showed reactivity of serum samples to numerous endothelial cell lysate-derived proteins. Pulmonary fibrosis, a recognized complication of systemic connective tissue disease, develops in connective tissue disease syndromes with pathogenetically established immune-based microvascular injury at other sites. A similar mechanism of antibody-mediated endothelial cell injury may be the basis of the tissue injury and fibrosing reparative response.


Assuntos
Doenças do Colágeno/complicações , Células Endoteliais/imunologia , Fibrose Pulmonar/etiologia , Animais , Anticorpos , Western Blotting , Doenças do Colágeno/patologia , Feminino , Imunofluorescência , Humanos , Doenças Pulmonares Intersticiais/patologia , Masculino , Microcirculação/patologia , Microcirculação/fisiopatologia , Pessoa de Meia-Idade , Fibrose Pulmonar/imunologia , Fibrose Pulmonar/patologia , Fibrose Pulmonar/fisiopatologia , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...