Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(9): 094701, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33003802

RESUMO

Searches for dark matter axions involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, until recently, to the use of non-superconducting metals by the presence of the external magnetic field. In this paper, we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of 5 × 105 for a selected mode.

2.
Rev Sci Instrum ; 91(7): 075103, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32752830

RESUMO

We present here a small-scale liquid helium immersion cryostat with an innovative optical setup suitable to work in long wavelength radiation ranges and under an applied magnetic field. The cryostat is a multi-stage device with several shielding in addition to several optical stages. The system has been designed with an external liquid nitrogen boiler to reduce liquid bubbling. The optical and mechanical properties of the optical elements were calculated and optimized for the designed configuration, while the optical layout has been simulated and optimized among different configurations based on the geometry of the device. The final design has been optimized for low-noise radiation measurements of proximity junction arrays under an applied magnetic field in the wavelength range λ = 250 µm-2500 µm.

3.
Phys Rev Lett ; 124(17): 171801, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32412290

RESUMO

A ferromagnetic axion haloscope searches for dark matter in the form of axions by exploiting their interaction with electronic spins. It is composed of an axion-to-electromagnetic field transducer coupled to a sensitive rf detector. The former is a photon-magnon hybrid system, and the latter is based on a quantum-limited Josephson parametric amplifier. The hybrid system consists of ten 2.1 mm diameter yttrium iron garnet spheres coupled to a single microwave cavity mode by means of a static magnetic field. Our setup is the most sensitive rf spin magnetometer ever realized. The minimum detectable field is 5.5×10^{-19} T with 9 h integration time, corresponding to a limit on the axion-electron coupling constant g_{aee}≤1.7×10^{-11} at 95% C.L. The scientific run of our haloscope resulted in the best limit on dark matter axions to electron coupling constant in a frequency span of about 120 MHz, corresponding to the axion-mass range 42.4-43.1 µeV. This is also the first apparatus to perform a wide axion-mass scanning by only changing the static magnetic field.

4.
Phys Rev Lett ; 104(17): 174801, 2010 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-20482112

RESUMO

The electron-positron collider DAPhiNE, the Italian Phi factory, has been recently upgraded in order to implement an innovative collision scheme based on large crossing angle, small beam sizes at the crossing point, and compensation of beam-beam interaction by means of sextupole pairs creating a "crab-waist" configuration in the interaction region. Experimental tests of the novel scheme exhibited an increase by a factor of 3 in the peak luminosity of the collider with respect to the performances reached before the upgrade. In this Letter we present the new collision scheme, discuss its advantages, describe the hardware modifications realized for the upgrade, and report the results of the experimental tests carried out during commissioning of the machine in the new configuration and standard operation for the users.

5.
Phys Rev Lett ; 99(23): 234801, 2007 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-18233375

RESUMO

In this Letter we report the first experimental observation of the double emittance minimum effect in the beam dynamics of high-brightness electron beam generation by photoinjectors; this effect, as predicted by the theory, is crucial in achieving minimum emittance in photoinjectors aiming at producing electron beams for short wavelength single-pass free electron lasers. The experiment described in this Letter was performed at the SPARC photoinjector site, during the first stage of commissioning of the SPARC project. The experiment was made possible by a newly conceived device, called an emittance meter, which allows a detailed and unprecedented study of the emittance compensation process as the beam propagates along the beam pipe.

6.
G Chir ; 18(1-2): 36-40, 1997.
Artigo em Italiano | MEDLINE | ID: mdl-9206479

RESUMO

The trend of the National mortality rate for gastric cancer in the general population and in the old people between 1955 and 1990 was studied. A decreased incidence of mortality in the general population whereas an increased mortality rate in elderly was found. Between 1990 and 1994, 17 patients over 70 years of age were operated on for gastric cancer. The influence of the ASA classification on postoperative complications was then evaluated registering a significant statistical difference between patients included in ASA III group and or > and major complications and mortality (P = 0.044). The surgical strategy in the management of elderly patients with gastric cancer is also discussed.


Assuntos
Adenocarcinoma/cirurgia , Idoso , Neoplasias Gástricas/cirurgia , Adenocarcinoma/mortalidade , Idoso de 80 Anos ou mais , Gastrectomia , Humanos , Excisão de Linfonodo , Cuidados Pós-Operatórios , Neoplasias Gástricas/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...