1.
Phytochem Anal ; 18(3): 204-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17500362

RESUMO

An analytical procedure was developed for the simultaneous determination of total hypericin (protopseudohypericin, pseudohypericin, protohypericin and hypericin) and hyperforin in Hypericum perforatum (St. John's wort) extracts and its preparations. The determination of total hypericin and hyperforin in one step was achieved by exposing the samples to artificial daylight in amber glass vials. This procedure allows both the photoconversion of the protoforms into the appropriate hypericins and the protection of the photosensitive hyperforin. For quantification, an HPLC method with electrochemical detection was applied. As an example of the application of the principle, two preparations containing St. John's wort were assayed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Hypericum/química , Perileno/análogos & derivados , Floroglucinol/análogos & derivados , Terpenos/análise , Antracenos , Antidepressivos/química , Compostos Bicíclicos com Pontes/análise , Compostos Bicíclicos com Pontes/química , Compostos Bicíclicos com Pontes/efeitos da radiação , Luz , Perileno/análise , Perileno/química , Perileno/efeitos da radiação , Floroglucinol/análise , Floroglucinol/química , Floroglucinol/efeitos da radiação , Extratos Vegetais/química , Pós/química , Comprimidos/química , Terpenos/química , Terpenos/efeitos da radiação
2.
Phytochem Anal ; 17(3): 162-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16749423

RESUMO

An HPLC method for the quantitation of hypericin using a new and sensitive amperometric detection is presented. Hypericin was eluted isocratically using a mobile phase consisting of ammonium acetate, methanol and acetonitrile. The oxidation was carried out with a glassy carbon electrode at a potential of + 1.1 V vs. an Ag-AgCl-KCl reference electrode. Under the conditions described, hypericin was separated at a retention time (Rt) of 12 min. Linearity was obtained over the range 0.035-1.30 microg/mL (r = 0.9994). The limit of detection was determined to be 0.010 ng on-column for hypericin. The method was applied to the determination of total hypericin (hypericin, pseudohypericin, protohypericin and protopseudohypericin) in extracts of St. John's wort using hypericin as an external standard. The protoforms were converted into hypericin and pseudohypericin by subjecting the sample to artificial light prior to chromatographic analysis. For the evaluation of total hypericin, the peak areas of pseudohypericin (Rt 3.7 min) and hypericin (Rt 12.0 min) were combined. The relative standard deviation in analysing samples containing Hypericum ranged from 2.5 to 5.4%.


Assuntos
Antidepressivos/análise , Hypericum/química , Perileno/análogos & derivados , Extratos Vegetais/química , Antracenos , Antidepressivos/química , Cromatografia Líquida de Alta Pressão , Eletroquímica , Perileno/análise , Perileno/química , Plantas Medicinais/química
3.
Biosens Bioelectron ; 21(4): 655-60, 2005 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-16202879

RESUMO

In this study, a 15-lipoxygenase-modified carbon paste electrode (15-LOX-MCPE) was developed in connection with the help of voltammetry, which can be used as an assay system for screening drugs with inhibiting lipoxygenase (LOX) activity. The influence of different experimental conditions (LOX loading of carbon paste, pH, type of buffer system etc.) was investigated in order to optimise the biosensing device. The best composition of the biosensor is 30% paraffin oil, 68% graphite powder and 2% LOX. The optimised voltammetric measurement medium is Sörensen/NaOH (0.1M, pH 9.0) using linoleic acid as a substrate. Under these conditions the hydroperoxy linoleic acid is formed, which can be oxidised at a potential of +0.9 V versus Ag/AgCl/3M KCl. The applicability of the LOX biosensor as assay of lipoxygenase inhibitors was successfully tested with nordihydroguaiaretic acid, zileuton and fenleuton, which are well known inhibitors of LOX.


Assuntos
Técnicas Biossensoriais/instrumentação , Carbono/química , Eletroquímica/instrumentação , Eletrodos , Inibidores de Lipoxigenase , Inibidores de Lipoxigenase/análise , Araquidonato 15-Lipoxigenase/análise , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Inibidores de Lipoxigenase/química , Pomadas
4.
Phytochem Anal ; 15(5): 320-4, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15508837

RESUMO

A differential pulse voltammetric method is presented for the determination of isopropylmethylphenols (carvacrol and/or thymol) in phytotherapeutic black seed oils. The voltammetric behaviours of these phenols were examined in various buffer systems over the pH range 3.5-10.0. In Sörensen buffered methanol solution (3:7; v:v; pH 8.5), the differential pulse voltammograms exhibited reproducible peaks at Ep + 0.49 V vs. silver-silver chloride-potassium chloride 3 M for both carvacrol and thymol. Under these conditions, a plot of peak height against concentration of the isopropylmethylphenols was found to be linear over the range 0.25-2.5 microg/mL (r = 0.999). The detection limit was 0.04 microg/mL. The described voltammetric method was tested on two black seed oils available on the Austrian market.


Assuntos
Monoterpenos/análise , Nigella sativa/química , Óleos de Plantas/química , Timol/análise , Cimenos , Ressonância Magnética Nuclear Biomolecular , Plantas Medicinais/química
5.
J Chromatogr A ; 1041(1-2): 181-5, 2004 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-15281267

RESUMO

An HPLC method with electrochemical detection for the determination of hyperforin extracts without using additional sample precleaning has been developed and validated. The hyperforin solutions were separated isocratically using a mobile phase consisting of 10% ammonium acetate buffer (0.5 M, pH 3.7)-MeOH-acetonitrile (10:40:50, v/v) at a flow rate of 0.8 mL/min. Hyperforin was detected amperometrically with a glassy carbon electrode at a potential of +1.1 V versus Ag/AgCl/3 M potassium chloride reference electrode. Under these conditions, a plot of integrated peak area versus concentration of hyperforin was found to be linear over the range of 0.054-5.4 microg/mL, with a relative standard deviation of 2.2-8.6%. The limit of detection was 0.050 ng on column. The determination of the hyperforin content in a commercially available St. John's Wort preparation exhibited a mean content of 1.56 mg. Recovery experiments led to a mean recovery rate of 97 +/- 5.8%. The proposed method is not time-consuming, sensitive and reproducible and is therefore suitable for routine analysis of hyperforin in herbal medicinal products.


Assuntos
Compostos Bicíclicos com Pontes/análise , Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Floroglucinol/análogos & derivados , Floroglucinol/análise , Terpenos/análise , Hypericum/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Agric Food Chem ; 52(6): 1423-6, 2004 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-15030190

RESUMO

A simple and accurate differential pulse polarographic method has been developed for the determination of oosporein in the culture broth of the fungus Beauveria brongniartii. This hydroxybenzoquinone derivative is the only major secondary metabolite secreted by this entomopathogenic fungus, which is used as biological pest control agent (BCA) against Melolontha melolontha larvae. It can be found in the host organism as well as in the formulated product. The polarographic behavior of oosporein was examined in various buffer systems over the pH range 3-10. In Britton-Robinson buffer/methanol solution (3:7 v/v, pH 5.5) the differential pulse polarograms exhibited reproducible peaks at E(p) = -0.18 V vs silver/silver chloride/potassium chloride (3 M). Under these conditions, a plot of peak height vs concentration of oosporein was found to be linear over the range 5.9 x 10(-)(7) to 2.5 x 10(-)(5) M (0.18-7.74 microg mL(-)(1); r = 0.9998). The detection limit was calculated to be 54 ng mL(-)(1). To evaluate the concentration of oosporein, the standard addition method was applied. The analysis of oosporein in the culture broth led to a mean value of 524.9 microg mL(-)(1) broth with a relative standard deviation (S(rel)) of +/-2.6%. The proposed polarographic method is accurate, not time-consuming, and it is of low cost because no separation steps are necessary.


Assuntos
Ascomicetos/metabolismo , Benzoquinonas/análise , Meios de Cultivo Condicionados/química , Micotoxinas/análise , Polarografia/métodos , Controle Biológico de Vetores , Microbiologia do Solo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...