1.
Intensive Care Med Exp ; 12(1): 51, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822111

RESUMO

BACKGROUND: Recirculation is a common problem in venovenous extracorporeal membrane oxygenation (VV ECMO) and may limit the effect of ECMO treatment due to less efficient blood oxygenation or unfavorable ECMO and ventilator settings. The impact of hypovolemia and positive end expiratory pressure (PEEP) on recirculation is unclear and poorly described in guidelines, despite clinical importance. The aim of this study was to investigate how hypovolemia, autotransfusion and PEEP affect recirculation in comparison to ECMO cannula distance and circuit flow. METHODS: In anesthetized and mechanically ventilated pigs (n = 6) on VV ECMO, we measured recirculation fraction (RF), changes in recirculation fraction (∆RF), hemodynamics and ECMO circuit pressures during alterations in PEEP (5 cmH2O vs 15 cmH2O), ECMO flow (3.5 L/min vs 5.0 L/min), cannula distance (10-14 cm vs 20-26 cm intravascular distance), hypovolemia (1000 mL blood loss) and autotransfusion (1000 mL blood transfusion). RESULTS: Recirculation increased during hypovolemia (median ∆RF 43%), high PEEP (∆RF 28% and 12% with long and short cannula distance, respectively), high ECMO flow (∆RF 49% and 28% with long and short cannula distance, respectively) and with short cannula distance (∆RF 16%). Recirculation decreased after autotransfusion (∆RF - 45%). CONCLUSIONS: In the present animal study, hypovolemia, PEEP and autotransfusion were important determinants of recirculation. The alterations were comparable to other well-known factors, such as ECMO circuit flow and intravascular cannula distance. Interestingly, hypovolemia increased recirculation without significant change in ECMO drainage pressure, whereas high PEEP increased recirculation with less negative ECMO drainage pressure. Autotransfusion decreased recirculation. The findings are interesting for clinical studies.

2.
Front Surg ; 11: 1358357, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38529470

RESUMO

Objectives: The aim of this study was to assess the potential of electrodermal activity (EDA) as a diagnostic tool for preoperative evaluation in hyperhidrosis patients. EDA levels and patterns in different skin areas were investigated before and after endoscopic thoracic sympathicotomy (ETS) and was compared to healthy subjects. Methods: Thirty-seven patients underwent two days of measurements before and after the operation. Twenty-five (67.5%) of the patients also had a third measurement after six months. Non-invasive EDA measurements, involving skin conductance, were sampled from five different skin areas while patients were at rest in supine and sitting positions or when subjected to stimuli such as deep inspirations, mental challenge, and exposure to a sudden loud sound. Results: Prior to the operation, hyperhidrosis patients showed higher spontaneous palm EDA variations at rest and stronger responses to stimuli compared to healthy subjects. Patients with facial blushing/hyperhidrosis or combined facial/palmar hyperhidrosis showed minimal spontaneous activity or responses, particularly during mental challenge and sound stimulus. Notably, palm EDA response was abolished shortly following sympathicotomy, although a minor response was observed after six months. Minimal EDA responses were also observed in the back and abdomen postoperatively. Conclusion: Hyperhidrosis patients showed stronger EDA response to stimuli compared to healthy subjects. Sympathicotomy resulted in the complete elimination of palm EDA responses, gradually returning to a limited extent after six months. These findings suggest that EDA recordings could be utilized in preoperative assessment of hyperhidrosis patients.

3.
J Heart Lung Transplant ; 43(1): 111-119, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37673384

RESUMO

BACKGROUND: Pump thrombosis (PT) and related adverse complications contributed to the HeartWare Ventricular Assist Device (HVAD) market withdrawal. Many patients still receive lifelong support, with deficient PT surveillance based on pump power trends. Analysis of pump vibrations is better for detecting PT. Here, we investigated the feasibility of an extracorporeal accelerometer to detect PT from pump vibrations propagated out on the driveline. METHODS: In a porcine HVAD model (n = 6), an accelerometer was attached to the pump as a reference and another to the driveline for comparisons of signals. In total, 59 thrombi were injected into the heart to induce PT, followed by intermittent thrombus washout maneuvers. Signals were compared visually in spectrograms and quantitatively in third harmonic saliences (S3H) by correlation analysis. Receiver operating characteristic curves expressed the method's outcome in sensitivity vs specificity, with the overall diagnostic performance in the area under the curve (AUC) score. RESULTS: Five experiments had good driveline signal strength, with clear spectrographic relationships between the 2 accelerometers. Third harmonic driveline vibrations were visible 20 vs 30 times in the reference. The comparison in S3H showed a strong correlation and yielded an AUC of 0.85. Notably, S3H proved robust regarding noise and false PT detections. CONCLUSIONS: An extracorporeal accelerometer on the driveline can be a readily available method for accurate HVAD PT detection before an accelerometer integration with left ventricular assist device is feasible.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Humanos , Animais , Suínos , Coração Auxiliar/efeitos adversos , Vibração , Trombose/diagnóstico , Trombose/etiologia , Trombose/epidemiologia , Estudos Retrospectivos
4.
J Heart Lung Transplant ; 42(8): 1005-1014, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37023840

RESUMO

BACKGROUND: Left ventricular assist devices (LVAD) provide circulatory blood pump support for severe heart failure patients. Pump inflow obstructions may lead to stroke and pump malfunction. We aimed to verify in vivo that gradual inflow obstructions, representing prepump thrombosis, are detectable by a pump-attached accelerometer, where the routine use of pump power (PLVAD) is deficient. METHOD: In a porcine model (n = 8), balloon-tipped catheters obstructed HVAD inflow conduits by 34% to 94% in 5 levels. Afterload increases and speed alterations were conducted as controls. We computed nonharmonic amplitudes (NHA) of pump vibrations captured by the accelerometer for the analysis. Changes in NHA and PLVAD were tested by a pairwise nonparametric statistical test. Detection sensitivities and specificities were investigated by receiver operating characteristics with areas under the curves (AUC). RESULTS: NHA remained marginally affected during control interventions, unlike PLVAD. NHA elevated during obstructions within 52-83%, while mass pendulation was most pronounced. Meanwhile, PLVAD changed far less. Increased pump speeds tended to amplify the NHA elevations. The corresponding AUC was 0.85-1.00 for NHA and 0.35-0.73 for PLVAD. CONCLUSION: Elevated NHA provides a reliable indication of subclinical gradual inflow obstructions. The accelerometer can potentially supplement PLVAD for earlier warnings and localization of pump.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Suínos , Animais , Coração Auxiliar/efeitos adversos , Trombose/diagnóstico , Curva ROC , Acelerometria , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/diagnóstico
5.
Med Eng Phys ; 110: 103917, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36564132

RESUMO

Inflow obstruction in left ventricular assist devices (LVAD) may lead to embolic stroke and pump malfunction. We investigated if an accelerometer detected graded LVAD inflow obstructions. Detection performances were compared to the current continuous surveillance routine based on the pump power consumption (PLVAD). In ten mock circuit experiments, four different-sized pendulating balloons obstructed HVAD™ inflow conduits cross-section areas by 14%-75%. Nonharmonic amplitudes (NHA) of continuous signals from a triaxial accelerometer attached to the LVAD were compared against single-point PLVAD values, using load and speed alterations as control interventions. We analyzed the NHA band power with a pairwise nonparametric statistical test. The detection performances were analyzed by receiver operating characteristics with areas under the curves (AUC). The NHA remained unaffected during load alterations. In contrast, NHA increased significantly from the 27% obstruction level (AUC≥0.82), an effect amplified by increased pump speed. PLVAD did not change significantly below the maximal 75% obstruction level (AUC≤0.36). In conclusion, NHA detected the inflow obstructions much better than PLVAD. The technique may provide a future monitoring modality of any pendulating obstructive inflow pathology.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Humanos , Cânula , Acelerometria
6.
Aerosp Med Hum Perform ; 90(5): 466-474, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31023407

RESUMO

BACKGROUND: Airline crew are being exposed to extended workdays and compressed work periods, with quick returns between duties, implying a heightened physiological and psychological strain that may lead to sleep deprivation and fatigue. The aim of the study was assessment of the effect of an extended day of flight duty and a compressed work week with regard to recovery, cumulative fatigue, and neurobehavioral performance.METHODS: We followed 18 pilots and 41 cabin crewmembers during four consecutive days of flight duty, comprising a total of ≥ 39 h, where the first day was ≥ 10 h. Information on demographics, work characteristics, health status, and physical activity was collected at baseline. Subjects completed logs for the first and fourth workday, including the Samn-Perelli Fatigue Checklist at three time points during these workdays. Two computer-based neurobehavioral tests were completed the evening prior to the first shift, and after the first and the fourth day of the work period.RESULTS: Number of flight sectors during the work period was 10-20. Self-reported fatigue levels increased during the workdays. Neurobehavioral test-scores did not deteriorate. The effects of each additional flight sector during the work period was elevated reaction times (RT) both among cabin crewmembers (B = 5.05 ms, 95% CI 0.6, 9.5) and pilots (B = 4.95 ms, 95% CI 0.4, 9.5). Precision was unaffected.DISCUSSION: Airline pilots and cabin crewmembers seem to obtain satisfactory sleep before and during the period of 4 consecutive days. The association between multiple flight sectors and increased fatigue supports previous findings.Goffeng EM, Wagstaff A, Nordby K-C, Meland A, Goffeng LO, Skare Ø, Lilja D, Lie J-AS. Risk of fatigue among airline crew during 4 consecutive days of flight duty. Aerosp Med Hum Perform. 2019; 90(5):466-474.


Assuntos
Medicina Aeroespacial/estatística & dados numéricos , Fadiga/epidemiologia , Doenças Profissionais/epidemiologia , Privação do Sono/complicações , Tolerância ao Trabalho Programado/fisiologia , Actigrafia , Adulto , Aviação/estatística & dados numéricos , Comércio/estatística & dados numéricos , Fadiga/diagnóstico , Fadiga/etiologia , Fadiga/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Noruega/epidemiologia , Doenças Profissionais/diagnóstico , Doenças Profissionais/etiologia , Doenças Profissionais/fisiopatologia , Pilotos/estatística & dados numéricos , Fatores de Tempo