Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Lab Chip ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847067

RESUMO

Throughout the COVID-19 pandemic, individuals potentially infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) were forcibly recalled to local or central hospitals, where the diagnostic results were obtained a couple of days after the liquid biopsies were subjected to conventional polymerase chain reaction (PCR). This slow output of such a complex and time-consuming laboratory procedure hindered its widespread application. To overcome the limitations associated with such a centralized diagnostic system, we developed a hand-held and all-in-one type test kit in which the analytical results can be obtained in only 30 min. The test kit consists of three major steps for on-site SARS-CoV-2 RNA detection: 1) virus lysis by heat, 2) RNA enrichment by membrane, and 3) real-time detection by colorimetric loop-mediated isothermal amplification (c-LAMP). The proposed device operates in a sample-to-answer format, is fully automated, and reduces dependence on traditional laboratory settings, facilitating large-scale population screening.

3.
Diagnostics (Basel) ; 14(9)2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38732380

RESUMO

Influenza viruses cause highly contagious respiratory diseases that cause millions of deaths worldwide. Rapid detection of influenza viruses is essential for accurate diagnosis and the initiation of appropriate treatment. We developed a loop-mediated isothermal amplification and lateral flow assay (LAMP-LFA) capable of simultaneously detecting influenza A and influenza B. Primer sets for influenza A and influenza B were designed to target conserved regions of segment 7 and the nucleoprotein gene, respectively. Optimized through various primer set ratios, the assay operated at 62 °C for 30 min. For a total of 243 (85 influenza A positive, 58 influenza B positive and 100 negative) nasopharyngeal swab samples, the performance of the influenza A/B multiplex LAMP-LFA was compared with that of the commercial AllplexTM Respiratory Panel 1 assay (Seegene, Seoul, Korea). The influenza A/B multiplex LAMP-LFA demonstrated a specificity of 98% for the non-infected clinical samples, along with sensitivities of 94.1% for the influenza A clinical samples and 96.6% for the influenza B clinical samples, respectively. The influenza A/B multiplex LAMP-LFA showed high sensitivity and specificity, indicating that it is reliable for use in a low-resource environment.

4.
PLoS One ; 19(5): e0302783, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753660

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) is one of the most serious and debilitating complications that can occur after total joint arthroplasty. Therefore, early diagnosis and appropriate treatment are important for a good prognosis. Recently, molecular diagnostic methods have been widely used to detect the causative microorganisms of PJI sensitively and rapidly. The Multiplex Loop-Mediated Isothermal Amplification (LAMP) method eliminates the complex temperature cycling and delays caused by temperature transitions seen in polymerase chain reaction (PCR) methods, making it faster and easier to perform compared to PCR-based assays. Therefore, this study developed a multiplex LAMP assay for diagnosing bacterial PJI using LAMP technology and evaluated its analytical and clinical performance. METHODS: We developed a multiplex LAMP assay for the detection of five bacteria: Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus agalactiae, Pseudomonas aeruginosa, and Escherichia coli, frequently observed to be the causative agents of PJI. The method of analytical sensitivity and cross-reactivity were determined by spiking standard strains into the joint synovial fluid. The analytical sensitivity of the multiplex LAMP assay was compared with that of a quantitative real-time PCR (qPCR) assay. Clinical performance was evaluated using 20 joint synovial fluid samples collected from patients suspected of having bacterial PJI. RESULTS: The analytical sensitivity of the gram-positive bacterial multiplex LAMP assay and qPCR were 105/104 CFU/mL, 103/103 CFU/mL, and 105/104 CFU/mL against S. agalactiae, S. epidermidis, and S. aureus, respectively. For P. aeruginosa and E. coli, the analytical sensitivity of the multiplex LAMP and qPCR assays were 105/104 and 106/104 CFU/mL, respectively. The multiplex LAMP assay detects target bacteria without cross-reacting with other bacteria, and exhibited 100% sensitivity and specificity in clinical performance evaluation. CONCLUSIONS: This multiplex LAMP assay can rapidly detect five high-prevalence bacterial species causing bacterial PJI, with excellent sensitivity and specificity, in less than 1 h, and it may be useful for the early diagnosis of PJI.


Assuntos
Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Infecções Relacionadas à Prótese , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Staphylococcus epidermidis/isolamento & purificação , Staphylococcus epidermidis/genética , Líquido Sinovial/microbiologia , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Staphylococcus aureus/isolamento & purificação , Staphylococcus aureus/genética
5.
Diagnostics (Basel) ; 13(18)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37761368

RESUMO

After three years of the SARS-CoV-2 pandemic, the demand for developing field-deployable point-of-care (PoC) molecular diagnostic tests has increased. Although RT-qPCR is the molecular diagnostic gold standard and is accurate, it is not readily applied to point-of-care testing (POCT). Meanwhile, rapid diagnostic kits have the disadvantage of low sensitivity. Recently, rapid isothermal nucleic acid amplification technology has emerged as an alternative for rapid diagnosis. Here, we developed a rapid SARS-CoV-2 reverse transcription loop-mediated isothermal amplification (RT-LAMP)-lateral flow assay (LFA) kit. This kit includes a Chelex-100/boiling nucleic acid extraction device and a one-step amplification detection apparatus capable of performing the entire process, from RNA extraction to detection, and diagnosing SARS-CoV-2 infection within 40 min without contamination. The detection limits of the rapid SARS-CoV-2 RT-LAMP-LFA kit were 100 plaque-forming units (PFUs) mL-1 and 10-1 PFU mL-1 for RNA samples extracted using the Chelex-100/boiling nucleic acid extraction device and commercial AdvansureTM E3 system, respectively. The sensitivity and specificity of the rapid SARS-CoV-2 RT-LAMP-LFA kit were 97.8% and 100%, respectively. Our SARS-CoV-2 RT-LAMP-LFA kit exhibited high sensitivity and specificity within 40 min without requiring laboratory instruments, suggesting that the kit could be used as a rapid POC molecular diagnostic test for SARS-CoV-2.

6.
Micromachines (Basel) ; 14(9)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37763821

RESUMO

Medium exchange of particles/cells to a clean buffer with a low background is essential for biological, chemical, and clinical research, which has been conventionally conducted using centrifugation. However, owing to critical limitations, such as possible cell loss and physical stimulation of cells, microfluidic techniques have been adopted for medium exchange. This study demonstrates a continuous on-chip washing process in a co-flow system using viscoelastic and Newtonian fluids. The co-flow system was constructed by adding a small amount of biocompatible polymer (xanthan gum, XG) to a sample containing particles or cells and introducing Newtonian fluids as sheath flows. Polymer concentration-dependent and particle size-dependent lateral migration of particles in the co-flow system were examined, and then the optimal concentration and the critical particle size for medium exchange were determined at the fixed total flow rate of 100 µL/min. For clinical applications, the continuous on-chip washing of white blood cells (WBCs) in lysed blood samples was demonstrated, and the washing performance was evaluated using a scanning spectrophotometer.

7.
Micromachines (Basel) ; 14(4)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37420947

RESUMO

An early and accurate diagnosis of Candida albicans is critical for the rapid antifungal treatment of candidemia, a mortal bloodstream infection. This study demonstrates viscoelastic microfluidic techniques for continuous separation, concentration, and subsequent washing of Candida cells in the blood. The total sample preparation system contains two-step microfluidic devices: a closed-loop separation and concentration device and a co-flow cell-washing device. To determine the flow conditions of the closed-loop device, such as the flow rate factor, a mixture of 4 and 13 µm particles was used. Candida cells were successfully separated from the white blood cells (WBCs) and concentrated by 74.6-fold in the sample reservoir of the closed-loop system at 800 µL/min with a flow rate factor of 3.3. In addition, the collected Candida cells were washed with washing buffer (deionized water) in the microchannels with an aspect ratio of 2 at a total flow rate of 100 µL/min. Finally, Candida cells at extremely low concentrations (Ct > 35) became detectable after the removal of WBCs, the additional buffer solution in the closed-loop system (Ct = 30.3 ± 1.3), and further removal of blood lysate and washing (Ct = 23.3 ± 1.6).

8.
Diagnostics (Basel) ; 13(8)2023 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-37189533

RESUMO

Influenza and coronaviruses cause highly contagious respiratory diseases that cause millions of deaths worldwide. Public health measures implemented during the current coronavirus disease (COVID-19) pandemic have gradually reduced influenza circulation worldwide. As COVID-19 measures have relaxed, it is necessary to monitor and control seasonal influenza during this COVID-19 pandemic. In particular, the development of rapid and accurate diagnostic methods for influenza and COVID-19 is of paramount importance because both diseases have significant public health and economic impacts. To address this, we developed a multi-loop-mediated isothermal amplification (LAMP) kit capable of simultaneously detecting influenza A/B and SARS-CoV-2. The kit was optimized by testing various ratios of primer sets for influenza A/B (FluA/FluB) and SARS-CoV-2 and internal control (IC). The FluA/FluB/SARS-CoV-2 multiplex LAMP assay showed 100% specificity for uninfected clinical samples and sensitivities of 90.6%, 86.89%, and 98.96% for LAMP kits against influenza A, influenza B, and SARS-CoV-2 clinical samples, respectively. Finally, the attribute agreement analysis for clinical tests indicated substantial agreement between the multiplex FluA/FluB/SARS-CoV-2/IC LAMP and commercial AllplexTM SARS-CoV-2/FluA/FluB/RSV assays.

9.
Diagnostics (Basel) ; 13(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37189598

RESUMO

Tuberculosis (TB) is one of the leading causes of infectious mortality from a single infectious agent, Mycobacterium tuberculosis (MTB). This study evaluated the performance of the newly developed BZ TB/NTM NALF assay, which integrated loop-mediated isothermal amplification and lateral flow immunochromatographic assay technologies, for the detection of MTB. A total of 80 MTB-positive samples and 115 MTB-negative samples were collected, all of which were confirmed by TB real-time PCR (RT-PCR) using either AdvanSureTM TB/NTM RT-PCR Kit or Xpert® MTB/RIF Assay. The performance of the BZ TB/NTM NALF assay was evaluated by calculating its sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) in comparison to those of the RT-PCR methods. Compared to the RT-PCR, the sensitivity, specificity, PPV, and NPV of BZ TB/NTM NALF assay were 98.7%, 99.1%, 98.7%, and 99.1%, respectively. The concordance rate between BZ TB/NTM NALF and RT-PCR was 99.0%. Rapid and simple detection of MTB is essential for global case detection and further elimination of TB. The performance of the BZ TB/NTM NALF Assay is acceptable with a high concordance with RT-PCR, indicating that it is reliable for use in a low-resource environment.

10.
PLoS One ; 18(4): e0283873, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37023101

RESUMO

Respiratory syncytial virus (RSV) is the leading cause of lower respiratory tract infections and hospitalization in infants and young children. Here, we analyzed the genetic diversity of RSV using partial G gene sequences in 84 RSV-A and 78 RSV- B positive samples collected in Seoul, South Korea, for 10 consecutive years, from 2010 to 2019. Our phylogenetic analysis revealed that RSV-A strains were classified into either the ON1 (80.9%) or NA1 (19.0%) genotypes. On the other hand, RSV-B strains demonstrated diversified clusters within the BA genotype. Notably, some sequences designated as BA-SE, BA-SE1, and BA-DIS did not cluster with previously identified BA genotypes in the phylogenetic trees. Despite this, they did not meet the criteria for the assignment of a new genotype based on recent classification methods. Selection pressure analysis identified three positive selection sites (amino acid positions 273, 274, and 298) in RSV-A, and one possible positive selection site (amino acid position 296) in RSV-B, respectively. The mean evolutionary rates of Korean RSV-A from 1999 to 2019 and RSV-B strains from 1991 and 2019 were estimated at 3.51 × 10-3 nucleotides (nt) substitutions/site/year and 3.32 × 10-3 nt substitutions/site/year, respectively. The population dynamics in the Bayesian skyline plot revealed fluctuations corresponding to the emergence of dominant strains, including a switch of the dominant genotype from NA1 to ON1. Our study on time-scaled cumulative evolutionary analysis contributes to a better understanding of RSV epidemiology at the local level in South Korea.


Assuntos
Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Lactente , Criança , Humanos , Pré-Escolar , Vírus Sincicial Respiratório Humano/genética , Infecções por Vírus Respiratório Sincicial/epidemiologia , Filogenia , Seul , Teorema de Bayes , República da Coreia/epidemiologia , Genótipo , Epidemiologia Molecular
11.
Diagnostics (Basel) ; 13(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36980425

RESUMO

Coronavirus disease (COVID-19) caused by SARS-CoV-2 infection has been a global pandemic for more than two years, and it is important to quickly and accurately diagnose and isolate patients with SARS-CoV-2 infection. The BZ COVID-19 NALF Assay could sensitively detect SARS-CoV-2 from a nasopharyngeal swab because it adopts both a loop-mediated isothermal amplification and lateral flow immunochromatography technology. In this study, a total of 389 nasopharyngeal swab samples, of which 182 were SARS-CoV-2 PCR positive and 207 were negative samples, were recruited. Compared to the Allplex™ SARS-CoV-2 Assay, the BZ COVID-19 NALF Assay showed 95.05% sensitivity and 99.03% specificity for detecting SARS-CoV-2. The concordance rate between the BZ COVID-19 NALF Assay and Allplex™ SARS-CoV-2 Assay was 97.69%. The turnaround time of the BZ COVID-19 NALF Assay is only about 40~55 min. The BZ COVID-19 NALF Assay is an accurate, easy, and quick molecular diagnostic test compared to the conventional PCR test for detection of SARS-CoV-2. In addition, the BZ COVID-19 NALF Assay is thought to be very useful in small size medical facilities or developing countries where it is difficult to operate a clinical laboratory.

12.
Diagnostics (Basel) ; 13(4)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36832131

RESUMO

The accurate detection of anti-neutralizing SARS-CoV-2 antibodies can aid in the understanding of the development of protective immunity against COVID-19. This study evaluated the diagnostic performance of the RapiSure (EDGC) COVID-19 S1 RBD IgG/Neutralizing Ab Test. Using the 90% plaque reduction neutralization test (PRNT90) as a reference, 200 serum samples collected from 78 COVID-19-positive and 122 COVID-19-negative patients were divided into 76 PRNT90-positive and 124 PRNT90-negative groups. The ability of the RapiSure test to detect antibodies was compared to that of the STANDARD Q COVID-19 IgM/IgG Plus test and that of PRNT90. The positive, negative, and overall percent agreement between the RapiSure and STANDARD Q test was 95.7%, 89.3%, and 91.5%, respectively, with a Cohen's kappa of 0.82. The RapiSure neutralizing antibody test results revealed a sensitivity of 93.4% and a specificity of 100% compared to the PRNT results, with an overall percent agreement of 97.5% and Cohen's kappa of 0.95. The diagnostic performance of the RapiSure test was in good agreement with the STANDARD Q COVID-19 IgM/IgG Plus test and comparable to that of the PRNT. The RapiSure S1 RBD IgG/Neutralizing Ab Test was found to be convenient and reliable and, thus, can provide valuable information for rapid clinical decisions during the COVID-19 pandemic.

13.
Diagnostics (Basel) ; 14(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38201382

RESUMO

Counting CD4+ T lymphocytes using flow cytometry is a standard method for monitoring patients with HIV infections. Simpler and cheaper alternatives to flow cytometry are in high demand because getting access to flow cytometers is difficult or impossible in resource-limited settings. We evaluated the performance of the Microscanner Plus, a simple and automated image-based cell counter, in determining CD4 counts against a flow cytometer. CD4 count results of the Microscanner Plus and flow cytometer were compared using samples from 47 HIV-infected patients and 87 healthy individuals. All CV% for precision and reproducibility tests were less than 10%. The Microscanner Plus's lowest detectable CD4 count was determined to be 15.27 cells/µL of whole blood samples. The correlation coefficient (R) between Microscanner Plus and flow cytometry for CD4 counting in 134 clinical samples was very high, at 0.9906 (p < 0.0001). The automated Microscanner Plus showed acceptable analytical performance for counting CD4+ T lymphocytes and may be particularly useful for monitoring HIV patients in resource-limited settings.

14.
Clin Orthop Surg ; 14(3): 466-473, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36061848

RESUMO

Background: To date, few studies have investigated the feasibility of the loop-mediated isothermal amplification (LAMP) assay for identifying pathogens in tissue samples. This study aimed to investigate the feasibility of LAMP for the rapid detection of methicillin-susceptible or methicillin-resistant Staphylococcus aureus (MSSA or MRSA) in tissue samples, using a bead-beating DNA extraction method. Methods: Twenty tissue samples infected with either MSSA (n = 10) or MRSA (n = 10) were obtained from patients who underwent orthopedic surgery for suspected musculoskeletal infection between December 2019 and September 2020. DNA was extracted from the infected tissue samples using the bead-beating method. A multiplex LAMP assay was conducted to identify MSSA and MRSA infections. To recognize the Staphylococcus genus, S. aureus, and methicillin resistance, 3 sets of 6 primers for the 16S ribosomal ribonucleic acid (rRNA) and the femA and mecA genes were used, respectively. The limit of detection and sensitivity (detection rate) of the LAMP assay for diagnosing MSSA and MRSA infection were analyzed. Results: The LAMP result was positive for samples containing 103 colony-forming unit (CFU)/mL for 16S rRNA, 104 CFU/mL for femA, and 105 CFU/mL for mecA. The limits of detection for 16S rRNA and femA were not different between MSSA and MRSA. For the 10 MSSA-positive samples, the LAMP assay showed 100% positive reactions for 16S rRNA and femA and a 100% negative reaction for mecA. For the 10 MRSA-positive samples, the LAMP assay showed 100% positive reactions for 16S rRNA and mecA but only 90% positive reactions for femA. The sensitivity (detection rate) of the LAMP assay for identifying MSSA and MRSA in infected tissue samples was 100% and 90%, respectively. Conclusions: The results of this study suggest that the LAMP assay performed with tissue DNA samples can be a useful diagnostic method for the rapid detection of musculoskeletal infections caused by MSSA and MRSA.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Estudos de Viabilidade , Humanos , Meticilina , Staphylococcus aureus Resistente à Meticilina/genética , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Ribossômico 16S/genética , Staphylococcus aureus/genética
15.
Micromachines (Basel) ; 13(7)2022 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-35888910

RESUMO

Water contamination is a critical issue that threatens global public health. To enable the rapid and precise monitoring of pathogen contamination in drinking water, a concentration technique for bacterial cells is required to address the limitations of current detection methods, including the culture method and polymerase chain reaction. Here we present a viscoelastic microfluidic device for the continuous concentration of bacterial cells. To validate the device performance for cell concentration, the flow characteristics of 2-µm particles were estimated in viscoelastic fluids at different concentrations and flow rates. Based on the particle flow distributions, the flow rate factor, which is defined as the ratio of the inlet flow rate to the outlet flow rate at the center outlet, was optimized to achieve highly concentrated bacterial cells by removal of the additional suspending medium. The flow characteristics of 0.5-, 0.7-, and 1.0-µm-diameter particles were evaluated to consider the effect of a wide spectrum of bacterial size distribution. Finally, the concentration factor of bacterial cells, Staphylococcus aureus, suspended in a 2000-ppm polyethylene oxide solution was found to be 20.6-fold at a flow rate of 20 µL/min and a flow rate factor of 40.

16.
J Clin Virol ; 153: 105213, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35724578

RESUMO

BACKGROUND: Human parainfluenza virus 3 (HPIV3) is a major respiratory pathogen that causes acute respiratory infections in infants and children. Since September 2021, an out-of-season HPIV3 rebound has been noted in Korea. The objective of this study was to analyze the molecular characteristics of the HPIV3 strains responsible for the outbreak in Seoul, South Korea. METHODS: A total of 61 HPIV3-positive nasopharyngeal swab specimens were collected between October and November 2021. Using 33 HPIV3-positive specimens, partial nucleotide sequences of the HPIV3 hemagglutinin-neuraminidase (HN) gene were aligned with previously published HN gene sequences for phylogenetic and genetic distance (p-distance) analyses. RESULTS: Phylogenetic tree revealed that all Seoul HPIV3 strains grouped within the phylogenetic subcluster C3. However, these strains formed a unique cluster that branched separately from the C3a lineage. This cluster showed 99% bootstrap support with a p-distance < 0.001. Genetic distances within the other C3 lineages ranged from 0.013 (C3a) to 0.023 (C3c). Deduced amino acid sequences of the HN gene revealed four protein substitutions in Seoul HPIV3 strains that have rarely been observed in other reference strains: A22T, K31N, G387S, and E514K. CONCLUSIONS: Phylogenetic analysis of Seoul HPIV3 strains revealed that the strain belonged to a separate cluster within subcluster C3. Genetic distances among strains within subcluster C3 suggest the emergence of a new genetic lineage. The emergence of a new genetic lineage could pose a potential risk of a new epidemic. Further monitoring of the circulating HPIV3 strains is needed to understand the importance of newly discovered mutations.


Assuntos
COVID-19 , Infecções por Paramyxoviridae , Criança , Proteína HN/química , Proteína HN/genética , Proteína HN/metabolismo , Humanos , Lactente , Pandemias , Vírus da Parainfluenza 3 Humana/genética , Filogenia , Seul
17.
Pathogens ; 11(2)2022 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-35215055

RESUMO

To reduce the morbidity and mortality of candidemia patients through rapid treatment, the development of a simple, rapid molecular diagnostic method that is based on nucleic acid extraction and is superior to conventional methods for detecting Candida in the blood is necessary. We developed a multiplex Candida Pan/internal control (IC) loop-mediated isothermal amplification (LAMP) assay and a simple DNA extraction boiling protocol using Chelex-100 that could extract yeast DNA in blood within 20 min. The Chelex-100/boiling method for DNA extraction showed comparable efficiency to that of the commercial QIAamp UCP Pathogen Mini Kit using Candida albicans qPCR. In addition, the Candida Pan/IC LAMP assay showed superior sensitivity to that of general Candida Pan and species qPCRs against clinical DNA samples extracted with the QIAamp UCP Pathogen Mini Kit and Chelex-100/boiling method. The Candida Pan/IC LAMP assay followed by Chelex-100/boiling-mediated DNA extraction showed high sensitivity (100%) and specificity (100%) against clinical samples infected with Candida. These results suggest that the Candida Pan/IC LAMP assay could be used as a rapid molecular diagnostic test for candidemia.

18.
PLoS One ; 17(2): e0262302, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35171943

RESUMO

Severe fever with thrombocytopenia syndrome (SFTS) and scrub typhus are endemic zoonotic diseases that pose significant public health threats in East Asia. As these two diseases share common clinical features, as well as overlapping disease regions, it is difficult to differentiate between SFTS and scrub typhus. A multiplex reverse-transcription loop­mediated isothermal amplification (RT-LAMP) assay was developed to detect large segments and GroES genes for SFTS virus (SFTSV) and Orientia tsutsugamushi (OT). The performance of the RT-LAMP assay was compared and evaluated with those of commercial PowerChek™ SFTSV real-time PCR and LiliF™ TSUTSU nested PCR for 23 SFTS and 12 scrub typhus clinical samples, respectively. The multiplex SFTSV/OT/Internal control (IC) RT-LAMP assay showed comparable sensitivity (91.3%) with that of commercial PowerChek™ SFTSV Real-time PCR (95.6%) and higher sensitivity (91.6%) than that of LiliF™ TSUTSU nested PCR (75%). In addition, the multiplex SFTSV/OT RT-LAMP assay showed 100% specificity and no cross-reactivity for blood from uninfected healthy patients and samples from patients infected with other fever viruses. Thus, the multiplex SFTSV/OT/IC RT-LAMP assay could serve as a useful point-of-care molecular diagnostic test for SFTS and scrub typhus.


Assuntos
DNA Bacteriano/análise , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/análise , Tifo por Ácaros/diagnóstico , Febre Grave com Síndrome de Trombocitopenia/diagnóstico , DNA Bacteriano/metabolismo , Humanos , Orientia tsutsugamushi/genética , Orientia tsutsugamushi/isolamento & purificação , Phlebovirus/genética , Phlebovirus/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral/metabolismo , Kit de Reagentes para Diagnóstico , Tifo por Ácaros/microbiologia , Sensibilidade e Especificidade , Febre Grave com Síndrome de Trombocitopenia/virologia
19.
Clin Lab ; 68(1)2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35023668

RESUMO

BACKGROUND: This study aimed to evaluate whether our equation model developed from the Sysmex hematology analyzer can discriminate patients with Plasmodium vivax (P. vivax) infection from those with acute febrile illness (AFI) and healthy controls. Besides, we compared our model with the previously studied models. METHODS: A total of 312 blood samples were collected from the P. vivax, AFI, and healthy control groups. All samples were tested for routine complete blood count conducted by using a Sysmex XE-2100 or XE-5000 analyzer. We compared the reportable and research parameters generated from the Sysmex analyzer among the three groups. The selected parameters that showed a significant difference between the P. vivax and the other group were included in the logistic regression analysis to develop our model (N-OIpv model). Moreover, we analyzed the CBC data according to the previous models, such as the presence of abnormal blue coded events in the WBC/BASO scattergram called the observer-interpretation (OIpv) model, and the previous equation model (N-OD1pv model) developed by Campuzano-Zuluaga et al. Results: The N-OIpv model, which consists of three parameters, such as mean cell volume, plateletcrit, and Lymph-X, showed the best performance for detection of malaria (97.4% accuracy). Also, this model can increase the sensitivity by about 11.9% to 18.1% compared with the OIpv and N-OD1pv models, respectively. CONCLUSIONS: We concluded that the N-OIpv model using the Sysmex hematology analyzer is a useful diagnostic tool in the routine laboratory workup for malaria.


Assuntos
Hematologia , Malária Vivax , Humanos , Contagem de Leucócitos , Malária Vivax/diagnóstico , Plasmodium vivax , República da Coreia
20.
J Clin Lab Anal ; 36(2): e24242, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35019184

RESUMO

BACKGROUND: Currently, SARS-CoV-2 RNA detection using real-time reverse-transcription PCR (rRT-PCR) is the standard diagnostic test for COVID-19 infection. Various rRT-PCR assays are currently used worldwide, targeting different genes of the SARS-CoV-2. Here, we compared the analytical sensitivity and clinical performance (sensitivity and specificity) of Allplex SARS-CoV-2/FluA/FluB/RSV assay (Seegene), Standard M nCoV real-time detection kit (SD Biosensor), and U-TOP COVID-19 detection kit (Seasun Biomaterials) for SARS-CoV-2 detection. METHODS: Two hundred and forty-nine nasopharyngeal swab samples were evaluated to compare the clinical performance of the rRT-PCR assays. For the analytical performance evaluation, two RNA controls with known viral loads-SARS-CoV-2 RNA control and SARS-COV-2 B.1.351 RNA control-were used to investigate the potential impact of SARS-CoV-2 variants, particularly the B.1.351 lineage. RESULTS: Limits of detection ranged from 650 to 1300 copies/ml for rRT-PCR assays, and the mean differences in cycle threshold (Ct ) values of the two RNA controls were within 1.0 for each target in the rRT-PCR assays (0.05-0.73), without any prominent Ct value shift or dropouts in the SARS-COV-2 B.1.351 RNA control. Using the consensus criterion as the reference standard, 89 samples were positive, whereas 160 were negative. The overall clinical performance of rRT-PCR assays was comparable (sensitivity 98.88%-100%; specificity 99.38%-100%), whereas the sensitivities of each target gene were more variable. CONCLUSIONS: The three rRT-PCR assays showed comparable analytical sensitivity and clinical performance. The analytical and clinical sensitivities of each target gene were influenced more by the primer and probe design than the target gene itself.


Assuntos
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular , Kit de Reagentes para Diagnóstico/virologia , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Nasofaringe/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Carga Viral , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...