Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Craniofac Surg ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38393303

RESUMO

This study aimed to measure masticatory performance (MP) using ß-carotene gummy jelly to investigate its relationship with skeletal properties in decompensated patients diagnosed with skeletal class III malocclusion. The study included 78 patients (38 men and 40 women) diagnosed with skeletal class III malocclusion without temporomandibular joint disorder and periodontal disease. MP was measured using a new masticatory measuring device and ß-carotene in the gummy jelly. Lateral and posteroanterior cephalograms were obtained, and skeletal properties (Me deviation, ANB, SNB, APDI, Wits, ODI, facial axis, body length, ramus length, SN-GoGn, anterior facial height, posterior facial height, saddle angle, articular angle, and gonial angle) were evaluated. MP differences according to age and sex and the effect of skeletal properties on MP were analyzed using multiple linear regression analysis. The MP of all patients was 3690.55±1428.77 mm², MP of the male group was 4043.05±1498.09 mm², and MP of the female group was 3355.68±1272.19 mm². Among the items investigated, the variable that affected MP was posterior facial height. Posterior facial height showed a positive correlation (P=0.022). There was no significant difference between MP and other skeletal properties (P>0.05). The severity of the hypodivergency in skeletal class III could affect MP. The relationship between facial asymmetry or skeletal relation and MP could not be explained in this study.

2.
Sci Rep ; 13(1): 17921, 2023 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-37863993

RESUMO

This study aimed to investigate the effects of shift work on periodontal disease in blue-and white-collar workers and to examine the interaction effects between occupation and work patterns. Data were collected from the Korea National Health and Nutrition Examination Survey conducted by the Korean Ministry of Health and Welfare for a total of nine years from 2007 to 2015. Participants with missing outcome variables were excluded from the analysis and a total of 32,336 participants were included in the final analysis. Univariable odds ratios (OR) were calculated using a logistic regression model with 95% confidence interval (CI). A multivariable logistic regression analysis was performed using the backward elimination method. The CONTRAST statement was used to analyze the interaction effect between occupation and work patterns. Multivariable logistic regression analysis revealed that interaction effects are present between the terms, occupational type and work pattern. Crude OR of shift work for periodontitis was 1.269 [CI 1.213-1.327, P < 0.05]. However, following adjustment for multiple confounding factors and the interaction effect term considered, this OR (1.269) increased to 1.381 [CI 1.253-1.523] in white-collar group while it decreased to 1.198 [1.119-1.283] in blue-collar. Crude OR of blue-collar (OR = 3.123, CI 2.972-3.281, P < 0.05) decreased to 1.151 [CI 1.049-1.262] when interaction effect to the shift work was considered. Shift work pattern increases the risk for periodontitis and this adverse effect is greater when white-collar workers are engaged comparing to blue-collar. The result of this study suggests that 24/7 lifestyle of the modern society poses health risks to the relevant people and the potential harm can be greater to white-collar workers.


Assuntos
Periodontite , Jornada de Trabalho em Turnos , Humanos , Inquéritos Nutricionais , Ocupações , Estilo de Vida , Periodontite/epidemiologia , Fatores de Risco
3.
J Craniomaxillofac Surg ; 51(9): 543-550, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37574384

RESUMO

The aim of this study was to convert medical images stored in 3 mm slices in the picture archiving and communication system (PACS) to 1 mm slices, using artificial intelligence (AI), and to analyze the accuracy of the AI. The original 1.0 mm CT slices of the facial bone were obtained from 30 patients and reformatted to a rough CT slice of 3.0 mm. CT slices of 1.0 mm were subsequently reconstructed from those of 3.0 mm using AI. The AI and rough CT images were superimposed on the original CT images. Fourteen hard-tissue and five soft-tissue landmarks were selected for measuring the discrepancy. The overall average differences in values for the hard-tissue landmarks were 1.31 ± 0.38 mm and 0.81 ± 0.17 mm for the rough and AI CT images, respectively. The values for the soft-tissue landmarks were 1.18 ± 0.35 mm and 0.54 ± 0.17 mm for the rough and AI CT images, respectively. The differences for all the landmarks, excluding point A and pogonion, were statistically significant. Within the limitations of the study it seems that CT images reconstructed using AI might provide more accurate clinical information with a discrepancy of less than 1.0 mm.

4.
Clin Oral Implants Res ; 34(6): 575-581, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36920314

RESUMO

OBJECTIVES: This study aimed to evaluate the effect of aging on the changes in implant stability over time following implant placement. MATERIALS AND METHODS: A total of 104 patients in four age ranges (group 1: <60 years, group 2: 61-70 years, group 3: 71-80 years, and group 4: >80 years) were included. Bone-level tapered implants were placed without implementing any bone augmentation procedure. The final torque value displayed on the implant engine during implant insertion was recorded. Cone-beam computed tomography (CBCT) was performed immediately after surgery to analyze the bone quality around the implant. Implant stability was measured immediately after surgery and 2, 4, and 8 weeks after surgery. RESULTS: In the CBCT image, higher grayscale values were observed in the order of group 1, group 2, and groups 3/4, with statistical significance (p < .05). There was no significant difference in the insertion torque values between age groups (p ≥ .05). Groups 1 and 2 showed lower implant stability values after 2 and 4 weeks compared to immediately and 8 weeks after surgery (p < .05); however, groups 3 and 4 showed no significant difference between the results measured at different timepoints (p ≥ .05). CONCLUSIONS: Implant treatment in elderly patients is successful showing a settled implant stability over time following implant placement when the implant is appropriately engaged in the alveolar bone in the absence of bone augmentation.


Assuntos
Implantes Dentários , Humanos , Idoso , Lactente , Estudos Prospectivos , Implantação Dentária Endóssea/métodos , Osso e Ossos , Densidade Óssea , Torque , Tomografia Computadorizada de Feixe Cônico/métodos
5.
BMC Oral Health ; 23(1): 124, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36829133

RESUMO

BACKGROUND: The objectives of this study were to use a digital camera to measure the discoloration of orthodontic elastomeric chains in various immersion solutions over different time periods and to determine the valid acceptability tolerances for color changes in orthodontic elastomeric chains by surveying digital photographs. METHODS: Orthodontic elastomeric chains were applied to the maxillary anterior teeth of nine typodont models. The models were divided into three groups and immersed in the curry, coffee, and wine solutions. The digital images of the elastomeric modules were captured and processed using commercial software after 30 min of immersion, thrice a day, for 28 days. The differences in color changes ([Formula: see text]), depending on the type of immersion solution and period, were analyzed using a repeated-measures analysis of variance (ANOVA) test. A web-based survey questionnaire was randomly distributed to 50 respondents for a visual analysis of the elastomeric chain discoloration. The relationship between the surveying score and [Formula: see text] value was analyzed using Spearman's correlation coefficient. The perceptibility and acceptability of elastomeric chain discoloration ([Formula: see text]) based on the type of immersion solutions and periods were analyzed using a regression model. RESULTS: Significant differences were observed in the discoloration of the elastomeric power chain depending on the immersion solution and period. The amount of discoloration was highest in curry, followed by coffee and wine (P < 0.05). The mean discoloration ([Formula: see text]) continued to increase over the entire immersion period. There was a significant correlation between visual scoring and discoloration ([Formula: see text]) over the entire period, especially in the early stages compared to the later stages (r = 0.918, P < 0.05). In 50% of the respondents, the predicted clinically unacceptable discoloration was between 4.46 and 9.98 and in 90% of the respondents, it was between 16.52 and 19.85. CONCLUSIONS: The amount of discoloration was the highest for curry, followed by coffee and wine, and continued to gradually increase during the observation period. Significant differences were found between the color measurements obtained and the visual assessment by observers. The observers varied in their tolerance for perceptibility and acceptability for elastomeric chain discoloration based on the type of dietary media.


Assuntos
Café , Resinas Compostas , Humanos , Cor , Teste de Materiais , Propriedades de Superfície
6.
Medicina (Kaunas) ; 58(11)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36363526

RESUMO

Background and Objectives: To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. Materials and Method: The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions. In addition, measurements were performed on the day of surgery, two weeks, one month, two months, and three months after surgery for a total of five times. After the standardization of the measured values, the differences and changes over time for each device were observed. Result: No difference in standardized values between the two devices was observed at any time point. In both devices, stability decreased at two weeks postoperatively but gradually increased thereafter. No differences were observed in the values according to the measurement direction. Conclusions: The damping capacity of Anycheck was similar to that of Periotest M. After a slight decrease in stability two weeks after implant placement, implant stability increased over time.


Assuntos
Implantes Dentários , Humanos , Estudos Prospectivos , Cicatrização
7.
Healthcare (Basel) ; 10(10)2022 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-36292386

RESUMO

(1) Background: The purpose of this study was to evaluate the 3-dimensional bony changes of the mandibular condyle in temporomandibular joints-osteoarthritis (TMJ-OA) patients treated with stabilization splint (SS) therapy using shape correspondence analysis. (2) Methods: A total of 27 adult patients (2 men and 25 women) with a mean age of 24.6 ± 3.9 years were included in this study. All patients were diagnosed with TMJ-OA and were treated with an SS. Cone-beam computed tomography data of the condylar head before and after SS therapy from 42 condyles (15 bilateral and 12 unilateral TMJ-OA) were used for the analysis. For the performance shape correspondence analysis (SPHARM-PDM), statistical differences were performed using the one-way analysis of variance and Scheffe post hoc tests. (3) Results: After SS treatment in TMJ-OA patients, bone resorption of the condyle head surface was predominant in the anterosuperior, superolateral, and superior areas, and bone formation was superior in the lateral, medial, posterosuperior, and posteromedial areas. The change in the condylar volume between the two groups was not statistically significant. (4) Conclusions: After SS treatment in TMJ-OA patients, there was both bone resorption and bone formation on the mandibular condyle head surface, which induced morphological changes in the condyle head.

8.
Sci Rep ; 12(1): 7538, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35534499

RESUMO

The objective of this retrospective study is to verify the effectiveness and safety of patient-specific titanium implants on maxillofacial bones, with a long-term follow-up. Total 16 patients with various maxillofacial defects underwent reconstruction using patient-specific titanium implants. Titanium implants, manufactured by electron beam melting, selective laser sintering, or milling, were inserted into the maxilla, mandible, or zygoma. Long-term follow-up (36.7 ± 20.1 months) was conducted after the surgery. Bone fusion of the titanium implant body, postoperative infection, implant malunion, functional results, patient satisfaction, subsidence, osteolysis around the implants, and complications were recorded and analyzed at the last follow-up. Of the 28 implants, only one failed to unite with the bone; therefore, revision surgery was performed. No osteolysis or subsidence around the titanium implants nor adverse events were observed; the mean VAS score for satisfaction was 9. All patients enrolled in this trial were esthetically and functionally satisfied with their surgical results, and fixation failure and esthetic dissatisfaction complications were well resolved. Patient-specific titanium showed satisfactory outcomes when used to treat various oral and maxillofacial defects. A 3D printed titanium implant can be effectively used in the reconstruction of the zygoma and mandible instead of autogenous bone without donor site morbidity.


Assuntos
Procedimentos de Cirurgia Plástica , Titânio , Humanos , Mandíbula/cirurgia , Próteses e Implantes , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos
9.
BMC Oral Health ; 21(1): 630, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876105

RESUMO

BACKGROUND: The inferior alveolar nerve (IAN) innervates and regulates the sensation of the mandibular teeth and lower lip. The position of the IAN should be monitored prior to surgery. Therefore, a study using artificial intelligence (AI) was planned to image and track the position of the IAN automatically for a quicker and safer surgery. METHODS: A total of 138 cone-beam computed tomography datasets (Internal: 98, External: 40) collected from multiple centers (three hospitals) were used in the study. A customized 3D nnU-Net was used for image segmentation. Active learning, which consists of three steps, was carried out in iterations for 83 datasets with cumulative additions after each step. Subsequently, the accuracy of the model for IAN segmentation was evaluated using the 50 datasets. The accuracy by deriving the dice similarity coefficient (DSC) value and the segmentation time for each learning step were compared. In addition, visual scoring was considered to comparatively evaluate the manual and automatic segmentation. RESULTS: After learning, the DSC gradually increased to 0.48 ± 0.11 to 0.50 ± 0.11, and 0.58 ± 0.08. The DSC for the external dataset was 0.49 ± 0.12. The times required for segmentation were 124.8, 143.4, and 86.4 s, showing a large decrease at the final stage. In visual scoring, the accuracy of manual segmentation was found to be higher than that of automatic segmentation. CONCLUSIONS: The deep active learning framework can serve as a fast, accurate, and robust clinical tool for demarcating IAN location.


Assuntos
Inteligência Artificial , Processamento de Imagem Assistida por Computador , Nervo Mandibular/diagnóstico por imagem , Redes Neurais de Computação , Aprendizado de Máquina Supervisionado
10.
J Clin Med ; 10(24)2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34945078

RESUMO

Occlusal displacement often occurs after surgery for condylar process fractures because it is difficult to reduce these fractures precisely. However, performing semi-rigid fixation using a sliding plate may overcome this limitation. A retrospective clinical comparison between semi-rigid and rigid fixations was performed. Among 34 patients who had unilateral condylar process fractures, 17 were treated with rigid fixation and the remaining with semi-rigid fixation using a sliding plate. For all patients, panoramic radiographs were collected 1 day and 6 months after surgery. In these radiographs, ramus height and condylar process inclination were measured, and the differences between the fractured and normal sides were assessed. Additionally, the radiographic density of the fracture area was measured. Differences in surgical outcomes and operative times between the two groups and changes in postoperative deviations within each group were analyzed. There was no statistically significant difference in ramus height and condylar process inclination between the two groups at postoperative day 1 and 6 months. Radio-density was observed to be higher in the rigid fixation group, and it increased with time in both groups. The semi-rigid fixation group had a significantly shorter operative time than the other group did. Semi-rigid and rigid fixations showed no differences in terms of effectiveness and outcomes of surgery. In terms of operative time, semi-rigid fixation was superior to rigid fixation.

11.
Int J Mol Sci ; 22(21)2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34768914

RESUMO

Our aim was to investigate the bone regeneration capacity of powder-type biphasic ceramic scaffold (BCP powder), block-type BCP (BCP block), and collagen-added block-type BCP (BCP collagen) with different concentrations of recombinant human bone morphogenetic protein 2 (rhBMP-2) in an animal model. Four rabbits were assigned to each of the following groups: no graft + rhBMP-2 (0.1/0.2 mg/mL), BCP powder + rhBMP-2 (0.1/0.2 mg/mL), BCP block + rhBMP-2 (0.1/0.2 mg/mL), and BCP collagen + rhBMP-2 (0.1/0.2 mg/mL), i.e., a total of 32 rabbits. Polycarbonate tubes (Φ 7 mm × 5 mm) for supporting scaffolds were fixed into a 7 mm round border. Subsequently, 0.1 mL of rhBMP-2 solutions with different concentrations was injected into the tubes. Both radiological and histomorphometric analyses showed that osteogenesis was not enhanced by increasing the concentration of rhBMP-2 in all groups at both 3 and 6 weeks. Radiological analysis showed that bone formation was higher in the BCP collagen group than in the BCP powder and BCP block groups at both rhBMP-2 concentrations at 3 weeks. rhBMP-2 enhanced bone formation; however, as the concentration increased, bone formation could not be enhanced infinitely. Collagen-added alloplastic graft material may be useful for mediating rapid bone formation in initial stages.


Assuntos
Doenças Ósseas/terapia , Proteína Morfogenética Óssea 2/administração & dosagem , Regeneração Óssea , Cerâmica/química , Osteogênese , Fraturas Cranianas/terapia , Alicerces Teciduais/química , Fator de Crescimento Transformador beta/administração & dosagem , Animais , Doenças Ósseas/metabolismo , Doenças Ósseas/patologia , Proteína Morfogenética Óssea 2/metabolismo , Masculino , Coelhos , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/metabolismo , Fraturas Cranianas/metabolismo , Fraturas Cranianas/patologia , Fator de Crescimento Transformador beta/metabolismo
12.
Int J Mol Sci ; 22(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34830400

RESUMO

This study aimed to evaluate the bone regeneration capacity of a customized alloplastic material and xenograft with recombinant human bone morphogenetic protein-2 (rhBMP-2). We prepared hydroxyapatite (HA)/tricalcium phosphate (TCP) pure ceramic bone blocks made using a 3D printing system and added rhBMP-2 to both materials. In eight beagle dogs, a total of 32 defects were created on the lower jaws. The defective sites of the negative control group were left untreated (N group; 8 defects), and those in the positive control group were filled with particle-type Bio-Oss (P group; 12 defects). The defect sites in the experimental group were filled with 3D-printed synthetic bone blocks (3D group; 12 defects). Radiographic and histological evaluations were performed after healing periods of 6 and 12 weeks and showed no significant difference in new bone formation and total bone between the P and 3D groups. The 3D-printed custom HA/TCP graft with rhBMP-2 showed bone regeneration effects similar to that of particulate Bio-Oss with rhBMP-2. Through further study and development, the application of 3D-printed customized alloplastic grafts will be extended to various fields of bone regeneration.


Assuntos
Proteína Morfogenética Óssea 2/genética , Regeneração Óssea/genética , Anormalidades Maxilomandibulares/terapia , Desenvolvimento Maxilofacial/genética , Fator de Crescimento Transformador beta/genética , Animais , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos/farmacologia , Fosfatos de Cálcio/farmacologia , Cães , Durapatita/farmacologia , Humanos , Arcada Osseodentária/patologia , Anormalidades Maxilomandibulares/genética , Anormalidades Maxilomandibulares/patologia , Impressão Tridimensional , Proteínas Recombinantes/genética , Proteínas Recombinantes/farmacologia , Crânio/efeitos dos fármacos , Crânio/crescimento & desenvolvimento , Crânio/patologia , Fator de Crescimento Transformador beta/farmacologia
13.
Medicina (Kaunas) ; 57(10)2021 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-34684046

RESUMO

Background and Objectives: The aim of our study was to test whether wide diameter (6 mm) implants perform differently from standard diameter (4 mm) implants in terms of marginal bone level and survival rate. Materials and Methods: Our sample comprised 72 patients who underwent surgery; a total of 80 implants were placed in the maxillary or mandibular molar region. Patients were divided into two groups according to the diameter of the implant, and were followed up for six years after the final setting of the prosthetics. In the test group, 40 implants with 6-mm diameter were inserted; in the control group, 40 standard diameter implants were inserted. Using panoramic radiographs, we investigated mesial and distal marginal bone levels around the implant fixtures. Results: After the first implant surgery, three implants, including one wide diameter and two standard diameter implants, failed due to lack of osseointegration. We did not note any fixture fracture during the six-year follow-up. After loading, we observed a six-year survival rate of 97.29% with no statistically significant difference from standard diameter implants, with a survival rate of 94.87%. Conclusions: This study shows that 6-mm diameter implants may be considered in the presence of adequate alveolar ridge width in the posterior maxillary and mandibular regions.


Assuntos
Mandíbula , Maxila , Seguimentos , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Dente Molar , Estudos Prospectivos , Resultado do Tratamento
14.
J Clin Med ; 10(15)2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34362106

RESUMO

This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; n = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement. Complications that occurred multiple times for single implants were counted. During the 12 month observation period, survival rates were 100% in both groups. No significant intergroup differences were observed for marginal bone resorption, probe depth, or bleeding index. However, mean plaque index was significantly lower in the MLF group at 12 months (p < 0.05). During the 12-month observation period, food impaction (26.3%) was the main complication in the MLF group and screw loosening (5.3%), prosthesis detachment (5.3%), and food impaction (5.3%) were observed in the MLA group. The results of this study suggest that the one-piece micro-locking implant system offers a predictable treatment method.

15.
Scanning ; 2021: 5535403, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34221213

RESUMO

The spread and application of computer-aided design/computer-aided manufacturing (CAD/CAM) technology have contributed to the rapid development of digitalization in dentistry. The accuracy of scan results is closely related to the devising subsequent treatment plans and outcomes. Professional standards for evaluating scanners are specified in the American National Standard/American Dental Association Standard 132 (ANSI/ADA No. 132). The aims of this study were to use the three samples mentioned in ANSI/ADA No. 132 and evaluate the accuracy and reproducibility of two extraoral scanners and an intraoral scanner based on the inspection standards recommended by ANSI/ADA No. 132. In this study, two trained operators used two extraoral scanners (E4, 3Shape, Denmark & SHINING DS100+, Shining, China) and an intraoral scanner (TRIOS SERIES3, 3Shape, Denmark) to perform 30 scans of each of the three samples at a temperature of 25 ± 2°C and export standard tessellation language files and used reverse engineering software to perform measurements and iterative nearest point matching experiments. The measured values obtained were compared with the reference values measured by a coordinate measuring machine (NC8107, Leader Metrology, USA). We performed a normal distribution test (Shapiro-Wilk test), the nonparametric Kruskal-Wallis test, and an independent-samples t-test to analyze the reproducibility of each scan for different models. The experimental results indicate that the trueness and precision of the two extraoral scanners and the intraoral scanner had a slight mean deviation. The trueness and precision of the three scanners on the curved surface and groove areas are poor. The accuracy and reproducibility of E4 outperformed SHINING and TRIOS. The iterative closest point matching experiment also showed good matching results. The two extraoral scanners and the intraoral scanner in this study can meet the basic clinical requirements in terms of accuracy, and we hope that digital technology will be more widely used in dentistry in the future.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional , Tecnologia Digital , Reprodutibilidade dos Testes , Software
16.
Materials (Basel) ; 14(14)2021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34300810

RESUMO

In porous titanium scaffolds manufactured via 3D printing, the differences in bone formation according to pore design and implantation period were studied. Titanium scaffolds with three types of different pore structures (Octadense, Gyroid, and Dode) were fabricated via 3D printing using the selective laser melting method. Mechanical properties of scaffolds were investigated. Prepared specimens were inserted into both femurs of nine rabbits and their clinical characteristics were observed. Three animals were sacrificed at the 2nd, 4th, and 6th weeks, and the differences in bone formation were radiologically and histologically analyzed. The percentage of new bone and surface density in the pore structure were observed to be approximately 25% and 8 mm2/mm3, respectively. There was no difference in the amount of newly formed bone according to the pore design at 2, 4, and 6 weeks. In addition, no differences in the amount of newly formed bone were observed with increasing time within the same pore design for all three designs. During the 6-week observation period, the proportion of new bones in the 3D-printed titanium scaffold was approximately 25%. Differences in bone formation according to the pore design or implantation period were not observed.

17.
J Clin Periodontol ; 48(8): 1066-1075, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34101218

RESUMO

AIM: This study aimed to investigate the association between work patterns and periodontal disease. MATERIALS AND METHODS: Data were collected from the Korea National Health and Nutrition Examination Survey between 2007 and 2012, and data from 22,508 subjects aged ≥19 years were included. An individual's work pattern was classified as either daytime or shift work. Sleep duration was categorized into three ranges: ≤5, 6-8, and ≥9 h/day. A multivariate logistic regression model was used to determine the adjusted odds ratio (OR) for CPI (Community Periodontal Index) ≥3. The CONTRAST statement was used to show the interaction effect of work patterns and sleep duration. RESULTS: The adjusted OR of shift work was 2.168 (CI: 1.929-2.438, p < .0001). Participants who sleep ≤5 or ≥9 h/day showed ORs 0.735 and 0.663, respectively (p = .0181). Interaction effect analysis revealed that the work pattern had a strong influence on periodontal condition when combined with the sleep amount. Shift workers with ≤5 or ≥ 9 h of sleep showed significantly increased ORs for CPI ≥3 (2.1406 and 2.3251, respectively, p < .0001). The ORs for daytime workers were comparable to the original values (≤5: 0.7348, p = .0292; ≥9: 0.6633, p = .0428). CONCLUSION: Altered sleep patterns caused by shift work have more influence on periodontal disease than sleep duration.


Assuntos
Doenças Periodontais , Transtornos do Sono do Ritmo Circadiano , Humanos , Inquéritos Nutricionais , Doenças Periodontais/complicações , Doenças Periodontais/epidemiologia , Sono , Tolerância ao Trabalho Programado
18.
Sci Rep ; 11(1): 11470, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34075179

RESUMO

This study evaluated the bone regeneration capacity and mechanical properties of block-type hydroxyapatite (HA)/tricalcium phosphate (TCP) scaffolds in response to different concentrations of polydeoxyribonucleotide (PDRN) and recombinant human bone morphogenic protein 2 (rhBMP-2). Thirty-two male white rabbits were used as a model of calvarial bone defect and classified into eight groups according to type and concentration of growth factor administered, viz., control group (only HA/TCP scaffold), scaffold + PDRN (0.1, 1, 5, and 10 mg/mL each) and scaffold + rhBMP-2 (0.01, 0.05, and 0.1 mg/mL each). The specimens were evaluated using histomorphometric and radiological analyses. Histomorphometric analyses indicated that the administration of PDRN did not increase bone formation. However, significant increases in bone formation were observed with the administration of rhBMP-2 at 0.05 and 0.10 mg/mL on week 8 compared to the control (p < 0.05). Radiological analyses revealed a significant increase in bone formation at week 8 with the administration of PDRN at 5 mg/mL and 10 mg/mL, and rhBMP-2 at 0.05 or 0.10 mg/mL compared to the control (p < 0.05). Our findings show that block-type HA/TCP scaffolds possess sufficient mechanical strength and bone regeneration capacity when used with optimal concentrations of growth factors.


Assuntos
Proteína Morfogenética Óssea 2 , Regeneração Óssea/efeitos dos fármacos , Cerâmica/química , Oligonucleotídeos/química , Crânio , Animais , Proteína Morfogenética Óssea 2/química , Proteína Morfogenética Óssea 2/farmacocinética , Proteína Morfogenética Óssea 2/farmacologia , Fosfatos de Cálcio/química , Durapatita/química , Humanos , Masculino , Oligonucleotídeos/farmacocinética , Oligonucleotídeos/farmacologia , Coelhos , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacocinética , Proteínas Recombinantes/farmacologia , Crânio/lesões , Crânio/metabolismo
19.
Scanning ; 2021: 6676149, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34055132

RESUMO

This study is aimed at assessing the dimensional alterations occurring in the alveolar bone after premolar extraction in dogs with histomorphometric and histological analysis. After atraumatic premolar extraction, tooth-derived bone graft material was grafted in the extraction socket of the premolar region in the lower jaws of six dogs in two experimental groups. In the second experimental group, BM-MSCs were added together with the graft. The control was left untreated on the opposite side. After twelve weeks, all six animals were sacrificed. Differences in alveolar bone height crests lingually and buccally, and alveolar bone width at 1, 3, and 5 mm infracrestally, were examined. Histologic study revealed osteoconductive properties of tooth biomaterial. A statistically significant difference was detected between the test and control groups. In the test groups, a reduced loss of vertical and horizontal alveolar bone dimensions compared with the control group was observed. Tooth bone graft material may be considered useful for alveolar ridge preservation after tooth extraction, as it could limit the natural bone resorption process.


Assuntos
Perda do Osso Alveolar , Células-Tronco Mesenquimais , Perda do Osso Alveolar/prevenção & controle , Processo Alveolar , Animais , Materiais Biocompatíveis , Cães , Extração Dentária , Alvéolo Dental
20.
Scanning ; 2021: 6675604, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33936357

RESUMO

BACKGROUND: Autogenous tooth transplantation is a reliable method for repairing missing teeth. Although it recently became a recognized and feasible treatment method in dentistry, the long-term efficacy of root canal therapy (RCT) has not been well confirmed. This study is aimed at determining whether RCT has a good effect on the success rate of teeth with complete roots in autogenous tooth transplantation. MATERIALS AND METHODS: Data were collected from the Korea University Guro Hospital. Data of patients who underwent autogenous tooth transplantation within 9 years were collected. We selected 29 teeth with complete roots as the research subjects in our study. None of the patients had any systemic diseases. All cases in this study were obtained with patient permission. RESULTS: According to the tooth vitality test, the autogenous teeth tested negative in dental pulp test and function. Nine of the 29 teeth with autogenous tooth transplantation were treated with RCT and survived throughout the observation period. However, 20 autogenous teeth were not treated with RCT, and eight of them did not survive. All statistical analyses were performed using IBM SPSS 20.0. The null hypothesis was rejected (p < 0.05). CONCLUSION: For complete root teeth, the success rate after autogenous tooth transplantation after RCT is higher than that of teeth not treated with RCT.


Assuntos
Tratamento do Canal Radicular , Dente , Humanos , Raiz Dentária/cirurgia , Transplante Autólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...