Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Eur J Radiol ; 170: 111228, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38101196

RESUMO

PURPOSE: To construct a predictive nomogram based on contrast-enhanced magnetic resonance imaging (MRI) and clinical findings for differentiating malignant from benign ampullary strictures. METHOD: In this retrospective study, 76 patients with ampullary strictures (51 benign and 25 malignant) who underwent contrast-enhanced MRI were enrolled. Imaging findings were evaluated independently by two abdominal radiologists who reached consensus. Clinical findings were also collected. Significant findings for malignant ampullary strictures were assessed by univariable and multivariable logistic regression analyses. Based on the results of multivariable analysis, a nomogram to differentiate malignant from benign ampullary strictures was developed and internally validated. RESULTS: In multivariable analysis, presence of an ampullary mass (odds ratio [OR]: 8.42, p = 0.047), bulging ampulla (OR: 8.32, p = 0.033), diffusion restriction of the ampulla (OR: 42.76, p = 0.004) on MRI, and jaundice (OR: 12.41, p = 0.019) were significant predictors of malignant ampullary strictures. A predictive nomogram was constructed using these findings. Among them, diffusion restriction of the ampulla showed the highest OR and predictor score on the nomogram. The calibration plots for internal validation achieved strong agreement between the predicted probabilities and the actual rates of malignant ampullary strictures. CONCLUSION: A combination of significant contrast-enhanced MRI and clinical findings of ampullary mass, bulging ampulla, diffusion restriction of the ampulla, and jaundice may be useful in the prediction of malignant ampullary stricture.


Assuntos
Ampola Hepatopancreática , Icterícia , Humanos , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/patologia , Estudos Retrospectivos , Nomogramas , Ampola Hepatopancreática/diagnóstico por imagem , Ampola Hepatopancreática/patologia , Imageamento por Ressonância Magnética/métodos , Icterícia/patologia
2.
J Korean Soc Radiol ; 84(4): 946-951, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37559801

RESUMO

Leiomyoma is a common benign tumor from smooth muscle cells, mostly in the uterus. Peritoneal leiomyomas (PLs) are extremely rare and mostly reported as disseminated peritoneal leiomyomatosis. However, to the best of out knowledge, radiologic findings of isolated PL are not reported in English literature. Herein, we introduce the radiologic findings of PL mimicking hepatic mass in a 34-year-old female. CT showed a mass with curvilinear heterogeneous enhancement at the liver's peripheral area. On MRI, the mass showed gradual and heterogeneous enhancement on gadoxetic acid-enhanced MRI and diffusion restriction. The radiologic diagnosis was a benign hepatic tumor, such as degenerated hemangioma, adenoma, and inflammatory myofibroblastic tumor; however, the mass was diagnosed as PL pathologically.

3.
Korean J Radiol ; 24(6): 482-497, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37271203

RESUMO

Sonazoid, a second-generation ultrasound contrast agent, was introduced for the diagnosis of hepatic nodules. To clarify the issues with Sonazoid contrast-enhanced ultrasonography for the diagnosis of hepatocellular carcinoma (HCC), the Korean Society of Radiology and Korean Society of Abdominal Radiology collaborated on the guidelines. The guidelines are de novo, evidence-based, and selected using an electronic voting system for consensus. These include imaging protocols, diagnostic criteria for HCC, diagnostic value for lesions that are inconclusive on other imaging results, differentiation from non-HCC malignancies, surveillance of HCC, and treatment response after locoregional and systemic treatment for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Radiologia , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Ultrassonografia/métodos , Meios de Contraste , República da Coreia
4.
Eur Radiol ; 32(11): 7566-7577, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35585200

RESUMO

OBJECTIVES: To construct a predictive nomogram for differentiating malignant from benign ampullary strictures using contrast-enhanced computed tomography (CT) findings combined with clinical findings. METHODS: In this retrospective study, 152 patients with ampullary stricture (98 benign and 54 malignant) who underwent contrast-enhanced CT were included. Various imaging findings of the ampulla, bile duct, main pancreatic duct, and periampullary area were evaluated and clinical findings including the presence of jaundice, carbohydrate antigen 19-9 level, and history of cholecystectomy were collected. Among them, statistically significant findings were identified using univariable and multivariable logistic regression analyses. A nomogram was constructed to differentiate benign and malignant ampullary strictures and was internally validated. RESULTS: Multivariable analysis revealed that jaundice (odds ratio [OR]: 17.33, p < 0.001), presence of an ampullary mass (OR: 24.40, p < 0.001), non-similar enhancement of the ampulla to the duodenum (OR: 31.96, p = 0.003), and proportional dilatation of the bile duct (OR: 7.98, p = 0.001) were independent significant factors for predicting the malignant ampullary stricture, and were used to construct a nomogram. Among them, non-similar enhancement of the ampulla to the duodenum showed the highest OR and predictor point on the nomogram. The calibration plots showed excellent agreement between the predicted probabilities and the actual rates of malignant ampullary strictures, on internal validation. CONCLUSIONS: Combination of clinical and imaging findings could aid in predicting malignant ampullary strictures using significant findings of jaundice, presence of ampullary mass, non-similar enhancement of the ampulla to the duodenum, and proportional dilatation of the bile duct. KEY POINTS: • The presence of jaundice, ampullary mass, non-similar enhancement of the ampulla, and proportional bile duct dilatation were significant findings for predicting malignant ampullary strictures. • Non-similar enhancement of the ampulla to the duodenum was a significant feature with the highest odds ratio for differentiating benign and malignant ampullary strictures. • The nomogram constructed using contrast-enhanced computed tomography imaging and clinical findings could aid in predicting malignant ampullary strictures.


Assuntos
Ampola Hepatopancreática , Neoplasias do Ducto Colédoco , Humanos , Constrição Patológica/patologia , Nomogramas , Estudos Retrospectivos , Ampola Hepatopancreática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Ducto Colédoco/patologia
5.
Medicine (Baltimore) ; 101(21): e29389, 2022 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-35623071

RESUMO

ABSTRACT: This study was conducted to evaluate the predictive value of spleen stiffness-spleen size-to-platelet ratio risk score (SSPS) as a noninvasive predictor of esophageal varices (EVs) and to compare it with others.In this retrospective study, from April 2017 to October 2018, a total of 65 patients with hepatitis B virus-related cirrhosis who underwent the liver and spleen stiffness (LS, and SS) measurements by 2 dimensional-shear wave elastography and endoscopic evaluation for EVs were enrolled. Liver stiffness-spleen size-to-platelet ratio risk score (LSPS) and SSPS were calculated. The prognostic values were assessed by the area under the receiver operating characteristic curve (AUC).Twenty-six patients had no EV on endoscopy. Among 39 patients who had EVs, 12 patients had high risk EVs. The AUCs of the LS value, SS value, LSPS, and SSPS for predicting EVs were 0.72, 0.77, 0.80, and 0.85, respectively. The AUCs of the LS value, SS value, LSPS, and SSPS for predicting high-risk EVs were 0.55, 0.78, 0.67, and 0.80, respectively. SSPS had the highest specificity, at 96.15%, for predicting EVs.SSPS may be beneficial to exclude from having EVs and it is expected that the frequency of performing endoscopies for screening EVs can be reduced.


Assuntos
Varizes Esofágicas e Gástricas , Varizes Esofágicas e Gástricas/diagnóstico , Varizes Esofágicas e Gástricas/etiologia , Varizes Esofágicas e Gástricas/patologia , Vírus da Hepatite B , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Cirrose Hepática/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Baço/diagnóstico por imagem , Baço/patologia
6.
Sci Rep ; 12(1): 1754, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-35110631

RESUMO

To evaluate the performance of a deep convolutional neural network (DCNN) in detecting local tumor progression (LTP) after tumor ablation for hepatocellular carcinoma (HCC) on follow-up arterial phase CT images. The DCNN model utilizes three-dimensional (3D) patches extracted from three-channel CT imaging to detect LTP. We built a pipeline to automatically produce a bounding box localization of pathological regions using a 3D-CNN trained for classification. The performance metrics of the 3D-CNN prediction were analyzed in terms of accuracy, sensitivity, specificity, positive predictive value (PPV), area under the receiver operating characteristic curve (AUC), and average precision. We included 34 patients with 49 LTP lesions and randomly selected 40 patients without LTP. A total of 74 patients were randomly divided into three sets: training (n = 48; LTP: no LTP = 21:27), validation (n = 10; 5:5), and test (n = 16; 8:8). When used with the test set (160 LTP positive patches, 640 LTP negative patches), our proposed 3D-CNN classifier demonstrated an accuracy of 97.59%, sensitivity of 96.88%, specificity of 97.65%, and PPV of 91.18%. The AUC and precision-recall curves showed high average precision values of 0.992 and 0.96, respectively. LTP detection on follow-up CT images after tumor ablation for HCC using a DCNN demonstrated high accuracy and incorporated multichannel registration.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Técnicas de Ablação , Idoso , Artérias/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/terapia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Compostos Radiofarmacêuticos , Estudos Retrospectivos
7.
Eur Radiol ; 32(6): 3974-3984, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35064803

RESUMO

OBJECTIVES: To compare the image quality and radiation dose of a deep learning image reconstruction (DLIR) algorithm compared with iterative reconstruction (IR) and filtered back projection (FBP) at different tube voltages and tube currents. MATERIALS AND METHODS: A customized body phantom was scanned at different tube voltages (120, 100, and 80 kVp) with different tube currents (200, 100, and 60 mA). The CT datasets were reconstructed with FBP, hybrid IR (30% and 50%), and DLIR (low, medium, and high levels). The reference image was set as an image taken with FBP at 120 kVp/200 mA. The image noise, contrast-to-noise ratio (CNR), sharpness, artifacts, and overall image quality were assessed in each scan both qualitatively and quantitatively. The radiation dose was also evaluated with the volume CT dose index (CTDIvol) for each dose scan. RESULTS: In qualitative and quantitative analyses, compared with reference images, low-dose CT with DLIR significantly reduced the noise and artifacts and improved the overall image quality, even with decreased sharpness (p < 0.05). Despite the reduction of image sharpness, low-dose CT with DLIR could maintain the image quality comparable to routine-dose CT with FBP, especially when using the medium strength level. CONCLUSION: The new DLIR algorithm reduced noise and artifacts and improved overall image quality, compared to FBP and hybrid IR. Despite reduced image sharpness in CT images of DLIR algorithms, low-dose CT with DLIR seems to have an overall greater potential for dose optimization. KEY POINTS: • Using deep learning image reconstruction (DLIR) algorithms, image quality was maintained even with a radiation dose reduced by approximately 70%. • DLIR algorithms yielded lower image noise, higher contrast-to-noise ratios, and higher overall image quality than FBP and hybrid IR, both subjectively and objectively. • DLIR algorithms can provide a better image quality, much better than FBP and even better than hybrid IR, while facilitating a reduction in radiation dose.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Multidetectores , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
Abdom Radiol (NY) ; 47(2): 538-546, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34919159

RESUMO

PURPOSE: The purpose of our study was to evaluate the role of timed barium esophagogram (TBE) in quantitative measurement of improved esophageal emptying in primary achalasia patients treated with POEM. Also, we investigated the correlation of TBE with improvement of clinical symptoms as measured by Eckardt score. METHODS: This retrospective study included 30 patients who underwent POEM due to primary achalasia. As a baseline study, all patients underwent TBE and were evaluated for clinical status by Eckardt score based on presence and frequency of dysphagia, regurgitation, substernal pain, and weight loss. Follow-up evaluation was performed within 3 months after POEM. Pre- and post-POEM TBE results were compared using a calculated value based on summation of height of the barium columns on 1-, 2- and 5-min delayed images. Also, the correlation of TBE with improvement of Eckardt score was evaluated using Pearson's correlation test. RESULTS: There was a significant decrease in the calculated value of height between pre- and post-POEM TBE studies (40.5 ± 15.8-17.0 ± 11.6, p < 0.01). Also, the Eckardt score decreased significantly after POEM (6.7 ± 2.0-0.8 ± 1.0, p < 0.01). Pearson's correlation test revealed a positive correlation between improvement of TBE results and Eckardt score (correlation coefficient = 0.56, p < 0.01). CONCLUSION: TBE is an objective method for quantitative measurement of improved esophageal emptying in primary achalasia patients treated with POEM and shows positive correlation with clinical symptoms evaluated by Eckardt score.


Assuntos
Acalasia Esofágica , Miotomia , Cirurgia Endoscópica por Orifício Natural , Bário , Acalasia Esofágica/diagnóstico por imagem , Acalasia Esofágica/cirurgia , Esfíncter Esofágico Inferior , Humanos , Miotomia/métodos , Cirurgia Endoscópica por Orifício Natural/métodos , Estudos Retrospectivos , Resultado do Tratamento
9.
Medicine (Baltimore) ; 100(19): e25814, 2021 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-34106619

RESUMO

ABSTRACT: The purpose of this phantom study is to compare radiation dose and image quality of abdominal computed tomography (CT) scanned with different tube voltages and tube currents, reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (IR) and deep learning image reconstruction (DLIR) algorithms.A total of 15 CT scans of whole body phantoms were taken with 3 different tube voltages and 5 different tube currents. The images were reconstructed with FBP, 30% and 50% hybrid IR adaptive statistical iterative reconstruction (ASIR-V), and low, medium and high strength DLIR algorithms. The image scanned with tube voltage/tube current of 120 kV/ 200 mA and reconstructed with FBP algorithm was chosen as the reference image. Five radiologists independently analyzed the images individually and also compared it with the reference image in overall, using the visual grading analysis. The mean score of each image was calculated and compared.Using DLIR algorithms, the radiation dose was reduced by 65.5% to 68.1% compared with the dose used in the reference image, while maintaining comparable image quality. Using the DLIR algorithm of medium strength, the image quality was even better than the reference image with a reduced radiation dose up to 36.2% to 50.0%. The DLIR algorithms generated better quality images than ASIR-V algorithms in all the data sets. In addition, among the data sets reconstructed with DLIR algorithms, image quality was the best at the medium strength level, followed by low and high.This phantom study suggests that DLIR algorithms may be considered as a new reconstruction technique by reducing radiation dose while maintaining the image quality of abdominal CTs.


Assuntos
Abdome/diagnóstico por imagem , Aprendizado Profundo , Doses de Radiação , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação
10.
Transl Cancer Res ; 10(3): 1420-1429, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35116467

RESUMO

BACKGROUND: Although helical tomotherapy (HT) tends to increase intermediate-dose spillage by increasing of low-dose region, this has not been fully determined in the clinical setting. Therefore, we investigated treatment outcomes of HT for hepatocellular carcinoma (HCC) with respect to intermediate-dose spillage. METHODS: We retrospectively reviewed 20 HCC patients, who received high-dose radiotherapy (RT) using HT with radical intent between April 2014 and September 2017. In accordance with the Barcelona Clinic Liver Cancer (BCLC) classification, stage was 0 in 7 patients, A in 3 patients, B in 5 patients, and C in 5 patients. Baseline Child-Pugh class was A in 18 patients and B in 2 patients. The median tumor size was 2.5 cm (range, 1-11 cm). Helical intensity-modulated radiotherapy (IMRT) technique was applied in all patients: among these, 13 patients were treated with stereotactic body radiotherapy (SBRT). The median fraction size was 12 Gy (range, 2-15 Gy), and the median total dose was 50 Gy (range, 44-60 Gy). Intermediate-dose spillage was assessed by the Radiation Therapy Oncology Group recommendation from 22 HT planning data, as follows: R50% means the ratio of the 50% prescription isodose volume to the planning target volume (PTV). RESULTS: The median follow-up period after HT was 22 months. The local progression-free survival (LPFS) and progression-free survival (PFS) rates were 89% and 59% at 1 year, and 82% and 30% at 2 years, respectively. The overall survival rate was 100% at 1 year and 85% at 2 years, respectively. In terms of intermediate-dose spillage, minor or major deviations were noted in the R50% of 20 HT plans (91%). However, 1 patient (5%) experienced classic radiation-induced liver disease, and severe toxicity ≥ grade 3 was not reported. CONCLUSIONS: Although HT for HCC tends to increase intermediate-dose spillage, the treatment results were favorable with that reported in other published studies.

11.
Eur Radiol ; 31(5): 3336-3346, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33185751

RESUMO

OBJECTIVES: To establish a prognostic nomogram for patients undergoing R0 resection for gallbladder cancer based on preoperative CT. METHODS: A total of 151 patients (64 males, 87 females; mean age, 73.26 years) with gallbladder cancer who underwent CT and surgery with margin-negative resection were retrospectively collected at two tertiary institutions. The demographic and radiologic parameters were analyzed using univariate and multivariate Cox regression analyses to identify independent prognostic factors. The final CT-based nomogram was constructed to predict prognosis after curative resection of gallbladder cancer. Calibration curves for the survival probabilities were obtained for internal validation. RESULTS: Mass-forming type (hazard ratio [HR], 28.80), bile duct invasion (HR, 4.76), duodenal invasion (HR, 6.32), colon invasion (HR, 4.37), gallstones (HR, 0.09), and cholecystitis (HR, 2.56) were significant independent predictors for recurrence-free survival (p < .05). Mass-forming type (HR, 8.16, p < .001), bile duct invasion (HR, 2.92, p = .013), duodenal invasion (HR, 3.72, p = .012), and regional lymph node metastasis (HR, 2.07, p = .043) were independent predictors of poor cancer-specific survival (CSS) and were used to construct the nomogram. The nomogram showed a good predictive ability for the probabilities of survival on the calibration curves, and the concordance index of the model in predicting CSS was .768. CONCLUSION: Preoperative CT findings could predict the prognosis of gallbladder cancer, and the CT-based nomogram accurately predicted CSS in patients with gallbladder cancer after attempted curative resection. KEY POINTS: • Among the preoperative imaging features, mass-forming type, bile duct invasion, duodenal invasion, and regional lymph node metastasis were independent predictors of poor cancer-specific survival. • The nomogram constructed using preoperative CT findings showed a good predictive ability for the survival on calibration curves, and the concordance index of the model in predicting cancer-specific survival was 0.768.


Assuntos
Neoplasias da Vesícula Biliar , Nomogramas , Idoso , Feminino , Neoplasias da Vesícula Biliar/diagnóstico por imagem , Neoplasias da Vesícula Biliar/cirurgia , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
World J Clin Cases ; 8(19): 4499-4504, 2020 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-33083410

RESUMO

BACKGROUND: In most cases, it is not difficult to differentiate common bile duct (CBD) stone from Ascaris infection because they are different disease entities and have different imaging findings. The two diseases usually demonstrate unique characteristic findings on computed tomography or magnetic resonance cholangiopancreatography. However, we report a rare case from our experience in which a CBD stone mimicked and was misdiagnosed as Ascaris. CASE SUMMARY: A 72-year-old male presented with elevated serum liver enzymes. Computed tomography showed a hyper-attenuated, elongated lesion in the CBD lumen and associated biliary inflammation. Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography revealed a linear filling defect in the bile duct. Moreover, elongated echogenic material with a central hypoechogenic area was seen on endoscopic ultrasound. Although the imaging findings caused us to suspect infection with the nematode Ascaris, the lesion was revealed to be a dark-brown-colored CBD stone through endoscopic extraction. CONCLUSION: We report a rare case of a CBD stone that mimicked Ascaris. We also review the literature for side-by-side comparisons of the imaging features of CBD stones and ascariasis.

13.
Radiology ; 297(3): 573-581, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32990512

RESUMO

Background Accurate identification of microvascular invasion (MVI) in hepatocellular carcinoma (HCC) before treatment is critical for selecting a proper treatment strategy. Purpose To evaluate the interobserver agreement and the diagnostic performance of the MRI assessment of MVI in HCC according to the level of radiologist experience. Materials and Methods This retrospective study included 100 patients with surgically confirmed HCCs smaller than 5 cm who underwent gadoxetic acid-enhanced MRI between 2013 and 2016. Eight postfellowship radiologists (four with 7-13 years of experience [more experienced] and four with 3-6 years of experience [less experienced]) evaluated four imaging features (nonsmooth tumor margin, irregular rim-like enhancement in the arterial phase, peritumoral arterial phase hyperenhancement, peritumoral hepatobiliary phase hypointensity) and assigned the possibility of MVI. Interobserver agreement was determined by using Fleiss κ statistics according to reviewer experience and tumor size (≤3 cm vs >3 cm). With reference standards of histopathologic specimens, the diagnostic performance in the identification of MVI was assessed by using receiver operating characteristic curve analysis. Results In 100 patients (mean age, 58 years ± 10 [standard deviation]; 70 men) with 100 HCCs (mean size, 2.8 cm ± 0.9), 39 (39%) HCCs had MVI. The overall interobserver agreement was fair to moderate for the imaging features and their combinations (κ = 0.38-0.47) and MVI probability (κ = 0.41; 95% confidence interval: 0.33, 0.45). More experienced reviewers demonstrated higher agreement in MVI probability than less experienced reviewers (κ = 0.55 vs 0.36, respectively; P = .002). Diagnostic performance of each reviewer was modest for MVI prediction (area under the receiver operating characteristic curve [AUC] range, 0.60-0.74). The AUCs for the diagnosis of MVI were lower for HCCs larger than 3 cm (range, 0.55-0.69) than for those less than or equal to 3 cm (range, 0.59-0.75). Conclusion Considerable interobserver variability exists in the assessment of microvascular invasion in hepatocellular carcinoma using MRI, even for more experienced radiologists. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Tang in this issue.


Assuntos
Carcinoma Hepatocelular/patologia , Competência Clínica , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Invasividade Neoplásica/patologia , Adulto , Idoso , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Retrospectivos
14.
Acta Radiol ; 61(6): 732-742, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31653185

RESUMO

BACKGROUND: The sensitivity of computed tomography (CT) for the detection of peritoneal metastasis (PM) of advanced gastric cancer (AGC) is relatively low. PURPOSE: To develop a predictive model to improve the sensitivity of PM detection and to externally validate this model. MATERIAL AND METHODS: We analyzed data from 78 patients with PM, who had undergone preoperative CT and subsequent surgery between January 2012 and December 2014, and 101 controls to form a derivation set, retrospectively. The following CT findings were evaluated: tumor size; Bormann type 4; enlarged lymph node; indirect findings of PM (peritoneal thickening, fat stranding, plaques or nodules on the peritoneum, and ascites); and definitive findings of PM (omental cake and rectal shelf). A predictive model was created using multivariate logistic regression. Receiver operating characteristic (ROC) analyses were performed to assess the diagnostic performance of the model. The accuracy was externally validated at other hospitals on 31 patients with PM and 48 patients without PM. RESULTS: Tumor size >5.2 cm, Bormann type 4, enlarged lymph node, peritoneal plaques or nodules, and ascites were independently associated with PM. It was able to predict PM with a higher area under the ROC curve (AUC) and sensitivity than definitive findings of PM (AUC 0.903 vs. 0.647, sensitivity 92.3% vs. 38.3%). External validation confirmed the predictive power with good inter-observer agreement. CONCLUSION: The CT-driven model shows higher AUC and sensitivity for prediction of PM and may help decision-making with the aim of improving care for patients with AGC.


Assuntos
Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/secundário , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peritônio/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Estômago/diagnóstico por imagem , Estômago/patologia , Adulto Jovem
15.
Ultrasound Med Biol ; 45(10): 2697-2703, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31326160

RESUMO

This study was conducted to define the effect of abdominal wall thickness (AWT) and its composition on the level of confidence in liver stiffness (LS) measurements obtained with 2-D shear wave elastography (2-D-SWE) in patients with chronic liver disease. In this retrospective study, a total of 1291 patients who underwent LS measurement by 2-D-SWE were enrolled. The abdominal wall was divided into three layers: layer 1 extended from the skin to the subcutaneous fat layer; layer 2 was the muscle layer; and layer 3 extended from the peritoneum to the liver capsule (including the omental fat layer, if present). We regarded the sums of layers 1-3 and layers 1 and 3 as the AWT and non-muscular layer thickness (NMT). Age/sex/body mass index-adjusted multivariate logistic regression analysis was performed to identify factors influencing the level of confidence of LS measurements. Three hundred eighty-six patients (29.9%) were classified in the unreliable LS group (standard deviation/median LS > 0.1). The fourth quartile of AWT and third and fourth quartiles of NMT/AWT were significantly associated with unreliable LS values (odds ratios = 2.103, 1.753 and 1.695, respectively). In conclusion, high AWT and NMT/AWT ratios reduce the confidence in LS measurements obtained with 2-D-SWE.


Assuntos
Parede Abdominal , Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Adulto , Pesos e Medidas Corporais/métodos , Doença Crônica , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
J Ultrasound Med ; 38(2): 423-431, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30039572

RESUMO

OBJECTIVES: To investigate the success rate of spleen stiffness measurement and factors that affect measurement success and to determine the spleen stiffness value of normal individuals by 2-dimensional shear wave elastography. METHODS: The spleen and liver stiffnesses of 313 consecutive patients were measured with SWE. The body mass index, abdominal wall thickness, spleen size, and liver stiffness of the patients were evaluated to identify factors associated with successful measurement of spleen stiffness. Patients were grouped by body mass index, spleen size, and liver stiffness, and the success rates and mean spleen stiffness values of the groups were compared. Independent predictors for successful spleen stiffness measurement and their cutoff values were evaluated. The mean spleen stiffness values of patients considered to have normal spleen stiffness were investigated. RESULTS: The overall success rate of spleen stiffness measurement was 52.9%. It was significantly higher in nonobese than in obese patients and in patients with splenomegaly and liver cirrhosis. The spleen stiffness value was higher in the splenomegaly group than the nonsplenomegaly group (P < .001) and increased as liver stiffness increased (P < .001). There was no significant difference in spleen stiffness values between the obese and nonobese groups. Abdominal wall thickness and splenic longitudinal diameter were identified as independent predictors of successful spleen stiffness measurement, and their cutoff values were 17.2 mm or less and greater than 9.4 cm, respectively. The mean spleen stiffness value ± SD of the normal patient group was 20.5 ± 5.4 kPa. CONCLUSIONS: The success rate of spleen stiffness measurement is lower than that of liver stiffness measurement. Spleen stiffness measurement is affected by abdominal wall thickness and spleen size.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Baço/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Baço/fisiologia , Adulto Jovem
17.
J Korean Med Sci ; 33(50): e299, 2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30534029

RESUMO

BACKGROUND: Sarcopenia is associated with a poor prognosis in patients with liver cirrhosis. However, it is not known whether the rate of skeletal muscle depletion is also associated with a poor prognosis. We investigated the prognostic impact of the rate of skeletal muscle depletion in patients with liver cirrhosis. METHODS: We included retrospectively all patients with liver cirrhosis who underwent both multiple computed tomography scans and hepatic venous pressure gradient (HVPG) measurements. RESULTS: A total of 131 patients with liver cirrhosis were enrolled. The mean age of the patients was 53.7 years and alcoholic liver disease was the most common cause (61.8%). Sixty-four patients (48.9%) were diagnosed with sarcopenia. The median changes in skeletal muscle area per year (ΔSMA/y) were -0.89%. During a median follow-up period of 46.2 months (range, 3.4-87.6), 45 patients (34.4%) died. In multivariate analyses, age, Child-Pugh score, HVPG, presence of sarcopenia and ΔSMA/y were independently associated with mortality. Cumulative mortality was significantly higher in patients with ΔSMA/y < -2.4% than those with ΔSMA/y ≥ -2.4% (log-rank test, P < 0.001). CONCLUSION: Both the presence and rate of change of sarcopenia are independently associated with long-term mortality in patients with liver cirrhosis.


Assuntos
Cirrose Hepática/diagnóstico , Sarcopenia/diagnóstico , Adulto , Feminino , Veias Hepáticas/fisiologia , Humanos , Coeficiente Internacional Normatizado , Cirrose Hepática/complicações , Cirrose Hepática/mortalidade , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Sarcopenia/complicações , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
18.
Br J Radiol ; 91(1085): 20170585, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29356562

RESUMO

OBJECTIVE: The need for liver biopsy has been increasing because genetic testing of specimens has become important for determining prognosis and management in patients with hepatic malignancy. We evaluated the feasibility of a device for biopsy tract ablation in patients with hepatic masses. METHODS: This prospective single-center pilot study was approved by our institutional review board and patients provided written informed consent. Between September 2015 and March 2016, 10 patients (6 males and 4 females, 35-66-years-old) who had hepatic masses and normal range of platelet count and prothrombin time were enrolled. After percutaneous ultrasound-guided biopsy, the biopsy tract was ablated with the device which consists of an insulation sheath and a radiofrequency applicator. Complications were evaluated with Doppler ultrasound immediately after the biopsy, with noncontrast abdominopelvic CT the day after the biopsy, and with a telephone interview 7 days after the biopsy. RESULTS: Tract ablation did not cause any pain in seven patients and caused minimal pain in three3 patients. Tract ablation was performed for a mean of 4.8 s (range, 4-6 s). No adverse events occurred during the procedure. Bleeding through the biopsy tract was not apparent on Doppler ultrasound, and abnormal fluid was not detected in the abdominal cavity on CT. Procedure-related complications were not reported on telephone interview. CONCLUSION: Biopsy tract ablation with the device is technically feasible. If the device is used appropriately considering its potential advantages, it may help to reduce the risk of complications associated with liver biopsy. Advances in knowledge: It is technically feasible to perform biopsy tract ablation with the radiofrequency ablation device after liver biopsy.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Fígado/patologia , Fígado/cirurgia , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Ultrassonografia de Intervenção
19.
J Ultrasound Med ; 37(2): 355-362, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28804946

RESUMO

OBJECTIVES: To compare the diagnostic performance for advanced hepatic fibrosis measured by 2D shear-wave elastography (SWE), using either the coefficient of variance (CV) or the interquartile range divided by the median value (IQR/M) as quality criteria. METHODS: In this retrospective study, from January 2011 to December 2013, 96 patients, who underwent both liver stiffness measurement by 2D SWE and liver biopsy for hepatic fibrosis grading, were enrolled. The diagnostic performances of the CV and the IQR/M were analyzed using receiver operating characteristic curves with areas under the curves (AUCs) and were compared by Fisher's Z test, based on matching the cutoff points in an interactive dot diagram. All P values less than 0.05 were considered significant. RESULTS: When using the cutoff value IQR/M of 0.21, the matched cutoff point of CV was 20%. When a cutoff value of CV of 20% was used, the diagnostic performance for advanced hepatic fibrosis ( ≥ F3 grade) with CV of less than 20% was better than that in the group with CV greater than or equal to 20% (AUC 0.967 versus 0.786, z statistic = 2.23, P = .025), whereas when the matched cutoff value IQR/M of 0.21 showed no difference (AUC 0.918 versus 0.927, z statistic = -0.178, P = .859). CONCLUSIONS: The validity of liver stiffness measurements made by 2D SWE for assessing advanced hepatic fibrosis may be judged using CVs, and when the CV is less than 20% it can be considered "more reliable" than using IQR/M of less than 0.21.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Fígado/diagnóstico por imagem , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
20.
Korean J Radiol ; 18(1): 173-179, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28096727

RESUMO

OBJECTIVE: To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle. MATERIALS AND METHODS: A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test. RESULTS: The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70-80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively. CONCLUSION: Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments.


Assuntos
Biópsia com Agulha de Grande Calibre/métodos , Hemorragia/etiologia , Fígado/patologia , Animais , Biópsia com Agulha de Grande Calibre/efeitos adversos , Eletrodos , Feminino , Heparina/química , Biópsia Guiada por Imagem , Tratamento por Radiofrequência Pulsada , Suínos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...