Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiology ; 202(2): 453-7, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9015073

RESUMO

PURPOSE: To validate a technique of computer-simulated dose reduction for conventional chest computed tomography (CT). MATERIALS AND METHODS: In 27 patients, CT scans were obtained at 200, 100, and 40 mAs at two levels. The raw data from the 200-mAs scan were modified on a computer workstation to simulate the increased noise present on 100- and 40-mAs scans. Real and simulated 100- and 40-mAs images were independently assessed in random order for overall image quality and radiologic findings by four subspecialty-trained chest radiologists who were blinded to the technique. The four observers were given paired real and simulated images. They were asked to identify the real image and note any difference in diagnostic quality. RESULTS: No difference was seen in overall image quality or radiologic findings between real and simulated images (P > .05). In the paired comparison, 433 of 864 (50.1%) real images were correctly identified. CONCLUSION: Computer modification of 200-mAs raw scan data to simulate 100- and 40-mAs noise levels produces reconstructed images indistinguishable from real 100- and 40-mAs scans. This technique provides realistic reduced-dose images without patient radiation exposure and with identical image registration and motion artifact.


Assuntos
Processamento de Imagem Assistida por Computador , Radiografia Torácica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Neoplasias Torácicas/diagnóstico por imagem
2.
Biophys J ; 46(4): 463-77, 1984 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-6498264

RESUMO

Recently it has become possible to measure fluorescence phase-shift and modulation data over a wide range of modulation frequencies. In this paper we describe the analysis of these data by the method of nonlinear least squares to determine the values of the lifetimes and fractional intensities for a mixture of exponentially decaying fluorophores. Analyzing simulated data allowed us to determine those experimental factors that are most critical for successfully resolving the emissions from mixtures of fluorophores. The most critical factors are the accuracy of the experimental data, the relative difference of the individual decay times, and the inclusion of data measured at multiple emission wavelengths. After measuring at eight widely spaced modulation frequencies, additional measurements yielded only a modest increase in resolution. In particular, the uncertainty in the parameters decreased approximately as the reciprocal of the square root of the number of modulation frequencies. Our simulations showed that with presently available precision and data for one emission bandpass, two decay times could be accurately determined if their ratio were greater than or equal to 1.4. Three exponential decays could also be resolved, but only if the range of the lifetimes were fivefold or greater. To reliably determine closely-spaced decay times, the data were measured at multiple emission wavelengths so that the fractional intensities of the components could be varied. Also, independent knowledge of any of the parameters substantially increased the accuracy with which the remaining parameters could be determined. In the subsequent paper we present experimental results that broadly confirm the predicted resolving potential of variable-frequency phase-modulation fluorometry.


Assuntos
Cinética , Modelos Biológicos , Matemática , Espectrometria de Fluorescência/métodos
3.
Biophys J ; 46(4): 479-86, 1984 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-6498265

RESUMO

We measured fluorescence phase shift and modulation data for one-, two- and, three-component mixtures of fluorophores at modulation frequencies ranging from 1 to 140 MHz. These data were analyzed using the least-squares procedure described in the preceding paper (Lakowicz, J. R., G. Laczko, M. Cherek, E. Gratton, and M. Limkeman, 1984, Biophys. J., 46:463-477). Using data obtained at a single emission bandpass, the lifetimes and preexponential factors of two-component mixtures could be easily resolved if the lifetimes differed by a factor of 2. With currently available instrumental stability, three-component mixtures could be resolved when the overall range of decay times was 10-fold, (e.g., 1.3, 4.4, and 12 ns). Measurement of phase and modulation data at several emission wavelengths, where the ratio of the preexponential factors varied, enhanced our ability to resolve closely spaced two and three-component decays. Two-component mixtures could then be resolved if the lifetimes differed by 30% (4.4 and 6.2 ns). Also, the multiple-wavelength data allowed the lifetimes and emission spectra of the three-components of a mixture to be resolved. These results demonstrated that resolution of multiexponential decay laws was possible using frequency-domain phase-modulation fluorometry.


Assuntos
Modelos Biológicos , Antracenos , Cinética , Matemática , Espectrometria de Fluorescência/métodos
4.
Biophys J ; 44(3): 315-24, 1983 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-6661490

RESUMO

A detailed description of the construction and performance of a variable frequency cross-correlation phase fluorometer is reported. The phase fluorometer operates over the frequency range 1-160 MHz with a maximum resolution of a few picoseconds. The effects of distortions introduced by the light modulator and the nonlinear dynode characteristic are discussed in terms of the harmonic content of the detected signal. A source of systematic errors due to nonhomogeneous modulation is also discussed with particular attention to the color effect of the photomultipliers. The application of the phase fluorometer to the measurement of very long and very short lifetimes is reported. Some application to the measurement of multiexponential decays is also illustrated.


Assuntos
Espectrometria de Fluorescência/instrumentação , Cloroplastos , Corantes , Etanol , Micelas , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...