Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 15(19)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37836037

RESUMO

A continuous-flow system based on a green and cost-effective monolithic starch cryogel column was successfully developed for removing methylene blue (MB). The proposed column exhibited high removal efficiency (up to 99.9%) and adsorption capacity (25.4 mg·g-1) for synthetic and real samples with an adsorbent cost of USD 0.02. The influence of various operation parameters, including the flow rate, initial concentration, column height, and temperature, on the MB removal efficiency was examined and reported. The MB removal efficiency remained >99% in the presence of potential interferences, highlighting the good performance of the cryogel column. The Yoon-Nelson dynamic model explained the MB adsorption better than the Bohart-Adams model, as indicated by the higher R2 values (R2 = 0.9890-0.9999) exhibited by the former and current trends of its parameters. The MB removal efficiency of the cryogel column remained at 62.7% after three reuse cycles. The wastewater containing MB collected from a local batik-production community enterprise in Phuket, Thailand was applied to the proposed continuous-flow system under optimum conditions, and results indicated that 99.7% of the MB present in 2.4 L of wastewater was removed. These results validate the excellent application potential of the cryogel column for the continuous-flow adsorption of MB. This study will facilitate future industrial applications and process designs of the continuous-flow system.

2.
Polymers (Basel) ; 15(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36771839

RESUMO

Toward the development of a practical and green approach for removing phosphate from water, a monolithic cryogel based on starch and calcium silicate hydrate (Cry-CSH) was employed as a phosphate adsorbent in a continuous flow system for the first time. The influence of flow rate, initial phosphate concentration, and adsorbent height on the adsorption efficiency was investigated. As the rate of flow and the initial concentration of phosphate increased, the total quantity of adsorbed phosphate dropped; however, the performance of the column was greatly enhanced by an increase in adsorbent height. The experimental data fit the Adams-Bohart model better than the Thomas and Yoon-Nelson models at the beginning of the adsorption process. To evaluate its applicability, the continuous flow system based on the monolithic Cry-CSH column was applied for the removal of phosphate from the discharge effluent of the Patong Municipality Wastewater Treatment Plant (Phuket, Thailand), achieving an excellent total adsorption of 94.61%.

3.
Polymers (Basel) ; 14(24)2022 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-36559910

RESUMO

A green monolithic starch cryogel was prepared and applied for the removal of methylene blue (MB) using a batch system. The influence of various experimental parameters on MB adsorption was investigated. High removal efficiency (81.58 ± 0.59%) and adsorption capacity (34.84 mg g-1) were achieved. The Langmuir model better fitted the experimental data (determination coefficient (R2) = 0.9838) than the Freundlich one (R2 = 0.8542), while the kinetics of MB adsorption on the cryogel followed a pseudo-second-order model. The adsorption process was spontaneous and endothermic with an activation energy of 37.8 kJ mol-1 that indicated physical adsorption. The starch cryogel was used for MB removal from a wastewater sample collected from a local Batik production community enterprise in Phuket, Thailand, and a removal efficiency of 75.6% was achieved, indicating that it has a high potential as a green adsorbent for MB removal.

4.
Molecules ; 27(21)2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36364112

RESUMO

Portable colorimetric hydrogel test kits are newly developed for the on-site detection of nitrite, nitrate, and phosphate in water. Griess-doped hydrogel was prepared at the bottom of a 1.5 mL plastic tube for nitrite detection, a nitrate reduction film based on zinc powder was placed on the inner lid of a second 1.5 mL plastic tube for use in conjunction with the Griess-doped hydrogel for nitrate detection, and a molybdenum blue-based reagent was entrapped within a poly(vinyl alcohol) hydrogel matrix placed at the bottom of a third 1.5 mL plastic tube to detect phosphate. These test kits are usable with on-mobile digital image colorimetry (DIC) for the on-site determination of nutrients with good analytical performance. The detection limits were 0.02, 0.04, and 0.14 mg L−1 for nitrite, nitrate, and phosphate, respectively, with good accuracy (<4.8% relative error) and precision (<1.85% relative standard deviation). These test kits and on-mobile DIC were used for the on-site determination of nutrients in the Pak Bang and Bang Yai canals, the main canals in Phuket, Thailand. The concentrations of nitrite, nitrate, and phosphate were undetectable to 0.60 mg L−1, undetectable to 2.98 mg L−1, and undetectable to 0.52 mg L−1, respectively.


Assuntos
Colorimetria , Nitritos , Colorimetria/métodos , Nitratos , Água , Hidrogéis , Nutrientes , Fosfatos , Plásticos
5.
Polymers (Basel) ; 14(11)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35683913

RESUMO

A novel reinforced recycled expanded polystyrene (r-EPS) foam/natural fiber composite was successfully developed. EPS was recycled by means of the dissolution method using an accessible commercial mixed organic solvent, while natural fibers, i.e., coconut husk fiber (coir) and banana stem fiber (BSF) were used as reinforcement materials. The treatment of natural fibers with 5% (w/v) sodium hydroxide solution reduces the number of -OH groups and non-cellulose components in the fibers, more so with longer treatments. The natural fibers treated for 6 h showed rough surfaces that provided good adhesion and interlocking with the polymer matrix for mechanical reinforcement. The tensile strength and impact strength of r-EPS foam composites with treated fibers were higher than for non-filled r-EPS foam, whereas their flexural strengths were lower. Thus, this study has demonstrated an alternative way to produce recycled polymer/natural fiber composites via the dissolution method, with promising enhanced mechanical properties.

6.
Molecules ; 26(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34684744

RESUMO

Benzo(a)pyrene (BaP) has been recognized as a marker for the detection of carcinogenic polycyclic aromatic hydrocarbons. In this work, a novel monolithic solid-phase extraction (SPE) sorbent based on graphene oxide nanoparticles (GO) in starch-based cryogel composite (GO-Cry) was successfully prepared for BaP analysis. Rice flour and tapioca starch (gel precursors) were gelatinized in limewater (cross-linker) under alkaline conditions before addition of GO (filler) that can increase the ability to extract BaP up to 2.6-fold. BaP analysis had a linear range of 10 to 1000 µgL-1 with good linearity (R2 = 0.9971) and high sensitivity (4.1 ± 0.1 a.u./(µgL-1)). The limit of detection and limit of quantification were 4.21 ± 0.06 and 14.04 ± 0.19 µgL-1, respectively, with excellent precision (0.17 to 2.45%RSD). The accuracy in terms of recovery from spiked samples was in the range of 84 to 110% with no significant difference to a C18 cartridge. GO-Cry can be reproducibly prepared with 2.8%RSD from 4 lots and can be reused at least 10 times, which not only helps reduce the analysis costs (~0.41USD per analysis), but also reduces the resultant waste to the environment.


Assuntos
Benzo(a)pireno/química , Grafite/química , Extração em Fase Sólida/métodos , Benzo(a)pireno/análise , Cálcio/análise , Cromatografia Líquida de Alta Pressão , Criogéis/química , Química Verde/métodos , Limite de Detecção , Nanopartículas/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Amido/análise , Poluentes Químicos da Água/análise
7.
Mikrochim Acta ; 187(12): 643, 2020 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-33155149

RESUMO

A novel colorimetric sheet based on Griess reagent-doped mesoporous silica nanoparticles was developed for nitrite detection. Griess reagent was adsorbed on long-range ordered hexagonal mesoporous silica nanoparticles and developed ink-bottle pores with some disorder. When the modified nanoparticles were bound using starch to fabricate a thin (~ 313 µm) colorimetric sheet, spherical particles with a rougher surface and some distortion of their mesoporosity were observed. The sheet was used in conjunction with digital image colorimetry (DIC) and provides a wide linear range of 0.05 to 2.50 mg L-1 with a low detection limit (15.0 µg L-1-NO2-, equal to 4.5 µg L-1 NO2--N), good inter-day precision (1.93%RSD), and excellent precision (2.67% relative error). The colorimetric sensors produced from the sheet costs only 0.04 USD each, while the DIC uses a standard smartphone for photographic detection. The method developed offers an easier and cheaper means of conducting rapid on-site determination of nitrite in water with reliable quantitative results. Graphical abstract.


Assuntos
Colorimetria/instrumentação , Nanopartículas/química , Nitritos/análise , Dióxido de Silício/química , Concentração de Íons de Hidrogênio , Cinética , Limite de Detecção , Microscopia Eletrônica de Varredura , Porosidade , Reprodutibilidade dos Testes , Difração de Raios X
8.
Anal Sci ; 36(10): 1261-1267, 2020 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-32475897

RESUMO

A tetramethylammonium hydroxide (TMAH)-doped starch film was developed for trinitrotoluene (TNT) detection. A purple Janowsky anion was obtained from the reaction of TNT with released TMAH. When the film was used in conjunction with digital image colorimetry (DIC), rapid quantitative analysis of TNT was achieved. The Red-Green-Blue (RGB) intensities analyzed from digital photographs of the purple product were used to establish calibration curves for TNT. A wide linear range (2.5 to 50 mgL-1) with good linearity (R2 > 0.99) was achieved for the quantification of TNT. Good precision (1.73 to 3.74%RSD) was obtained for inter-day tests (n = 5). The films were applied to test four post-blast soil samples and two positive results were observed. The concentrations quantified by DIC were in good agreement with spectrophotometry. The film was able to be stored in a freezer for 3 months with <4.3% change in performance.

9.
Food Chem ; 249: 154-161, 2018 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-29407918

RESUMO

A biodegradable colorimetric film was fabricated on the lid of portable tube for in-tube formaldehyde detection. Based on the entrapment of colorimetric reagents within a thin film of tapioca starch, the yellow reaction product was observed with formaldehyde. Intensity of the blue channel from the digital image of yellow product showed a linear relationship in the range of 0-25 mg L-1 with low detection limit of 0.7 ±â€¯0.1 mg L-1. Inter-day precision of 0.61-3.10%RSD were obtained with less than 4.2% relative error from control samples. The developed method was applied for various food samples in Phuket and formaldehyde concentration range was non-detectable to 1.413 mg kg-1. The quantified concentrations of formaldehyde in fish and squid samples provided relative errors of -7.7% and +10.8% compared to spectrophotometry. This low cost sensor (∼0.04 USD/test) with digital image colorimetry was thus an effective alternative for formaldehyde detection in food sample.


Assuntos
Colorimetria/métodos , Contaminação de Alimentos/análise , Formaldeído/análise , Alimentos Marinhos/análise , Animais , Colorimetria/economia , Colorimetria/instrumentação , Decapodiformes/química , Peixes , Espectrofotometria
10.
Forensic Sci Int ; 266: 202-208, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27314546

RESUMO

A cost effective hydrogel test kit was successfully developed for the detection of pre- and post-blast trinitrotoluene (TNT). A polyvinyl alcohol (PVA) hydrogel matrix was used to entrap the potassium hydroxide (KOH) colourimetric reagent. The easily portable test kit was fabricated in situ in a small tube to which the sample could be added directly. The test kit was used in conjunction with digital image colourimetry (DIC) to demonstrate the rapid quantitative analysis of TNT in a test soil sample. The built-in digital camera of an iPhone was used to capture digital images of the colourimetric products from the test kit. Red-Green-Blue (RGB) colour data from the digital images of TNT standard solutions were used to establish a calibration graph. The validation of the DIC method indicated excellent inter day precision (0.12-3.60%RSD) and accuracy (93-108% relative accuracy). Post-blast soil samples containing TNT were analysed using the test kit and were in good agreement with spectrophotometric analysis. The intensity of the RGB data from the TNT complex deviated by +6.3%, +5.1%, and -4.9% after storage of the test kits in a freezer for 3 months. The test kit was also reusable for up to 12 times with only -5.4%, +0.3%, and +4.0% deviations. The hydrogel test kit was applied in the detection of trace explosive residues at the scene of the recent Bangkok bombing at the Ratchaprasong intersection and produced positive results for TNT demonstrating its operational field application as a rapid and cost effective quantitative tool for explosive residue analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...