Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Genomics ; 23(1): 666, 2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36131238

RESUMO

Severe peripheral nerve injury leads to the irreparable disruption of nerve fibers. This leads to disruption of synapses with the designated muscle, which consequently go through progressive atrophy and damage of muscle function. The molecular mechanism that underlies the re-innervation process has yet to be evaluated using proteomics or transcriptomics. In the present study, multi-dimensional data were therefore integrated with transcriptome and proteome profiles in order to investigate the mechanism of re-innervation in muscles. Two simulated nerve injury muscle models in the rat tibial nerve were compared: the nerve was either cut (denervated, DN group) or crushed but with the nerve sheath intact (re-innervated, RN group). The control group had a preserved and intact tibial nerve. At 4 weeks, the RN group showed better tibial nerve function and recovery of muscle atrophy compared to the DN group. As the high expression of Myh3, Postn, Col6a1 and Cfi, the RN group demonstrated superior re-innervation as well. Both differentially expressed genes (DEGs) and proteins (DEPs) were enriched in the peroxisome proliferator-activated receptors (PPARs) signaling pathway, as well as the energy metabolism. This study provides basic information regarding DEGs and DEPs during re-innervation-induced muscle atrophy. Furthermore, the crucial genes and proteins can be detected as possible treatment targets in the future.


Assuntos
Denervação Muscular , Proteoma , Animais , Músculo Esquelético/fisiologia , Atrofia Muscular/genética , Atrofia Muscular/patologia , Compressão Nervosa , Regeneração Nervosa/fisiologia , Receptores Ativados por Proliferador de Peroxissomo , Ratos
2.
Quant Imaging Med Surg ; 12(5): 2904-2916, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35502392

RESUMO

Background: Acetabular reconstruction in Crowe type IV developmental dysplasia of the hip (DDH) can be a challenging procedure for surgeons. A high risk of acetabular revision has been reported to be associated with extremely small acetabular prostheses. However, to our knowledge, quantitative morphological and coverage evaluations of the true acetabulum in Crowe IV hips have been infrequently conducted. Useful bony landmarks for acetabular reconstruction can also facilitate satisfactory intraoperative implantation. The aim of the present study was to investigate the anatomical size, orientation angles, and 2/3-dimensional (2D/3D) coverage parameters of the true acetabulum in Crowe IV hips; evaluate the feasibility of standard cup (>44 mm) implantation at the true acetabulum in Crowe IV hips; and identify the optimal position and useful bony landmarks of the acetabular reaming center in Crowe IV hips. Methods: A total of 42 Crowe IV hips in 37 patients and 36 normal hips were included in this study. Based on pelvic 3D computed tomography (CT) reconstruction, anatomical size and integral volume of the true acetabulum were measured quantitatively. Through standard-size cup-simulated implantation, morphological assessments of the true acetabulum included Cup-CE, Cup-Sharp, acetabular anteversion angle, and thickness of the medial wall. Acetabular sector angles (ASAs) and the component coverage ratio were measured to provide coverage indices. Acetabular reconstruction was also performed at different vertical levels to measure medial bone stock and 3D component coverage. Bony landmarks for optimal component center location were also determined. Results: The anatomic shape and volume of the acetabular triangle were significantly smaller in Crowe IV hips. Compared with the control group, the dysplastic acetabulum was more anteverted and abductive, with a thicker medial wall. According to the true acetabulum, bone stock was relatively sufficient in the posterior direction and prominently deficient in the anterosuperior and superior direction. The average 3D component coverage reached 79.89% by standard-sized cup implantation, with the most satisfactory coverage achieved at the true acetabulum (at the level of 13.32 mm above the transverse acetabular ligament). Regarding the component opening plane, the optimal component center was located at the midpoint between the superolateral and posteroinferior points of the true acetabulum. Conclusions: The most satisfactory coverage was achieved at the level of the true acetabulum, of which the most prominent deficiency was mainly located in the anterosuperior and superior directions. The optimal component center was determined to be the midpoint between the superolateral and posteroinferior points of the true acetabulum.

3.
J Integr Neurosci ; 20(2): 359-366, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34258934

RESUMO

This preliminary research determines whether a combination of reverse end-to-side neurorrhaphy and rapamycin treatment achieves a better functional outcome than a single application after prolonged peripheral nerve injury. We found that the tibial nerve function of the reverse end-to-side + rapamycin group recovered better, with a higher tibial function index value, higher amplitude recovery rate, and shorter latency delay rate (P < 0.05). The reverse end-to-side + rapamycin group better protected the gastrocnemius muscle with more forceful contractility, tetanic tension, and a higher myofibril cross-sectional area (P < 0.05). Combining reverse end-to-side neurorrhaphy with rapamycin treatment is a practical approach to promoting the recovery of chronically denervated muscle atrophy after peripheral nerve injury.


Assuntos
Antibacterianos/farmacologia , Músculo Esquelético/fisiopatologia , Regeneração Nervosa/fisiologia , Procedimentos Neurocirúrgicos , Traumatismos dos Nervos Periféricos/terapia , Sirolimo/farmacologia , Neuropatia Tibial/terapia , Animais , Antibacterianos/administração & dosagem , Terapia Combinada , Modelos Animais de Doenças , Eletromiografia , Feminino , Denervação Muscular , Traumatismos dos Nervos Periféricos/tratamento farmacológico , Traumatismos dos Nervos Periféricos/cirurgia , Ratos , Ratos Sprague-Dawley , Sirolimo/administração & dosagem , Neuropatia Tibial/tratamento farmacológico , Neuropatia Tibial/cirurgia
4.
BMC Musculoskelet Disord ; 21(1): 434, 2020 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-32622357

RESUMO

BACKGROUND: Design modifications in prostheses may cause alterations in gait kinematics, thus influencing functional restoration of knees after total knee arthroplasty (TKA). The aim of the study was to investigate the differences in gait kinematics and clinical outcomes after single radius (SR) versus multiple radius (MR) TKA. METHOD: The present retrospective study included 38 unilateral TKA involving 20 knees using MR design implant and 18 knees using SR design implant. Thirty-six healthy volunteers were also recruited. The mean follow-up time was 16 ± 3 months. At the end of follow-up, the 6 degrees of freedom (DOF) kinematics of knees and range of motion (ROM) were measured with a portable optical tracking system. Knee society score (KSS) and knee injury, and osteoarthritis outcome score (KOOS) were also collected. RESULTS: Patients in the SR group had significantly higher scores in activities of daily living (84.7 ± 15.9) and sports and recreation (67.5 ± 25.2) KOOS sub-score than MR group (69.9 ± 17.6, P = 0.012; 50.0 ± 20.8, P = 0.027, respectively). Significant differences were detected between MR knees and SR knees (1.82° ± 3.11° vs 4.93° ± 3.58°, P = 0.009), and MR knees and healthy knees (1.82° ± 3.11° vs 3.62° ± 3.52°, P = 0.032) in adduction/abduction ROM. The proximal/distal translation was significantly smaller in MR knees (0.58 ± 0.54 cm) compared with SR knees (1.03 ± 0.53 cm, P = 0.003) or healthy knees (0.84 ± 0.45 cm, P = 0.039). SR knees (0.24 ± 0.40 cm) had smaller translation compared with the MR group (0.54 ± 0.33 cm, P = 0.017) and control group (0.67 ± 0.36 cm, P = 0.028). No significant difference was detected in the other DOFs during the gait cycle. Significant difference was detected in extension/flexion, internal/external rotation, adduction/abduction, proximal/distal and medial/lateral among MR, SR and healthy knees. CONCLUSION: After TKA, patients have altered gait kinematics compared with the control group. MR and SR design showed varied characteristics in 6 DOF gait kinematics, which could be the cause of the difference in functional outcome.


Assuntos
Artroplastia do Joelho/métodos , Marcha , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Atividades Cotidianas , Idoso , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/cirurgia , Caminhada
5.
J Orthop Surg Res ; 14(1): 431, 2019 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-31829273

RESUMO

BACKGROUND: Revision total hip arthroplasty (THA) with large acetabular defect remains a challenge. Though trabecular metal (TM) cup and augments have been introduced in defect reconstruction with good result, the accurate positioning of implant is important to avoid complications. Therefore, we aimed to evaluate the usefulness of three-dimensional (3D) simulation and 3D model in assisting implant positioning during complex revision THA. METHODS: Sixteen patients (18 hips) who underwent revision THA with a Paprosky type III acetabular defect were analyzed retrospectively. Placement of acetabular cup and TM augments was simulated with 3D simulation software and 3D model preoperatively. Cup anteversion, abduction angle, and hip center were measured in each case preoperatively and postoperatively. Primary outcome was the percentage of outliers according to Lewinnek safe zone and Harris hip score (HHS). Secondary outcome was the correlation between the 3D planned and the postoperative value. RESULTS: The percentage of outliers was significantly corrected from 77.78% (14/18) preoperatively to 38.88% (7/18) postoperatively (p = 0.04). There was a significant correlation between mean planned cup anteversion and postoperative value (13.39 vs 11.99, r = 0.894; p < 0.001). There was a significant correlation between mean planned abduction and postoperative value (42.67 vs 44.91, r = 0.921, p < 0.001). The number of planned and used augments was the same in all the cases. In 15 cases (83.33%), the size of planned and used TM augments was the same. The HHS was significantly improved at final follow-up (80.94 vs 27.50, p < 0.001). No cases presented dislocation or radiological signs of loosening. CONCLUSION: Preoperative 3D simulation and model were considered the useful method to assist implant positioning in revision THA with complex acetabular defect, with moderate to high accuracy and satisfied clinical outcome.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Impressão Tridimensional , Idoso , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/normas , Feminino , Seguimentos , Prótese de Quadril/normas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...