Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 23(1): 933, 2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36280811

RESUMO

BACKGROUND: With the increasing number of studies on osteoporosis and muscle adipose tissue, existing studies have shown that skeletal muscle tissue and adipose tissue are closely related to osteoporosis by dual-energy x-ray absorptiometry (DXA) measurement. However, few studies have explored whether the skeletal muscle and adipose tissue index measured at the lumbar spine 3 (L3) level are closely related to bone mineral density (BMD) and can even predict osteoporosis. Therefore, this study aimed to prove whether skeletal muscle and adipose tissue index measured by computed tomography (CT) images based on a single layer are closely related to BMD. METHODS: A total of 180 participants were enrolled in this study to obtain skeletal muscle index (SMI), psoas muscle index (PMI), subcutaneous fat index (SFI), visceral fat index (VFI), and the visceral-to-subcutaneous ratio of the fat area (VSR) at L3 levels and divide them into osteoporotic and normal groups based on the T-score of DXA. Spearman rank correlation was used to analyze the correlation between SMI, PMI, SFI, VFI, VSR, and BMD. Similarly, spearman rank correlation was also used to analyze the correlation between SMI, PMI, SFI, VFI, VSR, and the fracture risk assessment tool (FRAX). Receiver operating characteristic (ROC) was used to analyze the efficacy of SMI, PMI, SFI, VFI, and VSR in predicting osteoporosis. RESULTS: BMD of L1-4 was closely correlated with SMI, PMI, VFI and VSR (r = 0.199 p = 0.008, r = 0.422 p < 0.001, r = 0.253 p = 0.001, r = 0.310 p < 0.001). BMD of the femoral neck was only correlated with PMI and SFI (r = 0.268 p < 0.001, r = - 0.164 p-0.028). FRAX (major osteoporotic fracture) was only closely related to PMI (r = - 0.397 p < 0.001). FRAX (hip fracture) was closely related to SMI and PMI (r = - 0.183 p = 0.014, r = - 0.353 p < 0.001). Besides, FRAX (major osteoporotic fracture and hip fracture) did not correlate with VFI, SFI, and VSR. SMI and PMI were statistically significant, with the area under the curve (AUC) of 0.400 (95% confidence interval 0.312-0.488 p = 0.024) and 0.327 (95% confidence interval 0.244-0.410 p < 0.001), respectively. VFI, SFI, and VSR were not statistically significant in predicting osteoporosis. CONCLUSIONS: This study demonstrated that L3-based muscle index could assist clinicians in the diagnosis of osteoporosis to a certain extent, and PMI is superior to SMI in the diagnosis of osteoporosis. In addition, VFI, SFI, and VSR do not help clinicians to diagnose osteoporosis well.


Assuntos
Fraturas do Quadril , Osteoporose , Fraturas por Osteoporose , Humanos , Fraturas por Osteoporose/diagnóstico , Músculos Psoas/diagnóstico por imagem , Fatores de Risco , Medição de Risco/métodos , Osteoporose/diagnóstico por imagem , Absorciometria de Fóton/métodos , Densidade Óssea/fisiologia , Fraturas do Quadril/diagnóstico , Vértebras Lombares/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
Clinics (Sao Paulo) ; 70(10): 714-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26598086

RESUMO

The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values or the number of outliers (±3°) between the extramedullary and intramedullary groups. A reduced tourniquet time was associated with the intramedullary guide. No significant difference in the complication rate was noted between the two groups. Neither extramedullary nor intramedullary tibial alignment was more accurate in facilitating the tibial cut. Use of an intramedullary guide results in a shorter tourniquet time and exhibits a similar complication rate as the extramedullary guide.


Assuntos
Artroplastia do Joelho/métodos , Tíbia/cirurgia , Viés , Humanos , Radiografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Tíbia/diagnóstico por imagem , Fatores de Tempo , Torniquetes
4.
Clinics ; 70(10): 714-719, Oct. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-762964

RESUMO

The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values or the number of outliers (±3°) between the extramedullary and intramedullary groups. A reduced tourniquet time was associated with the intramedullary guide. No significant difference in the complication rate was noted between the two groups. Neither extramedullary nor intramedullary tibial alignment was more accurate in facilitating the tibial cut. Use of an intramedullary guide results in a shorter tourniquet time and exhibits a similar complication rate as the extramedullary guide.


Assuntos
Humanos , Artroplastia do Joelho/métodos , Tíbia/cirurgia , Viés , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Torniquetes , Tíbia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...