Resultados 1 - 20 de 91
Filtrar
1.
Radiother Oncol ; : 110404, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942121

RESUMO

PURPOSE: To investigate quality assurance (QA) techniques for in vivo dosimetry and establish its routine uses for proton FLASH small animal experiments with a saturated monitor chamber. METHODS AND MATERIALS: 227 mice were irradiated at FLASH or conventional (CONV) dose rates with a 250 MeV FLASH-capable proton beamline using pencil beam scanning to characterize the proton FLASH effect on abdominal irradiation and examining various endpoints. A 2D strip ionization chamber array (SICA) detector was positioned upstream of collimation and used for in vivo dose monitoring during irradiation. Before each irradiation series, SICA signal was correlated with the isocenter dose at each delivered dose rate. Dose, dose rate, and 2D dose distribution for each mouse were monitored with the SICA detector. RESULTS: Calibration curves between the upstream SICA detector signal and the delivered dose at isocenter had good linearity with minimal R2 values of 0.991 (FLASH) and 0.985 (CONV), and slopes were consistent for each modality. After reassigning mice, standard deviations were less than 1.85 % (FLASH) and 0.83 % (CONV) for all dose levels, with no individual subject dose falling outside a ±â€¯3.6 % range of the designated dose. FLASH fields had a field-averaged dose rate of 79.0 ±â€¯0.8 Gy/s and mean local average dose rate of 160.6 ±â€¯3.0 Gy/s. In vivo dosimetry allowed for the accurate detection of variation between the delivered and the planned dose. CONCLUSION: In vivo dosimetry benefits FLASH experiments through enabling real-time dose and dose rate monitoring allowing mouse cohort regrouping when beam fluctuation causes delivered dose to vary from planned dose.

2.
J Appl Clin Med Phys ; : e14400, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831639

RESUMO

BACKGROUND: Quality assurance (QA) for ultra-high dose rate (UHDR) irradiation is a crucial aspect in the emerging field of FLASH radiotherapy (FLASH-RT). This innovative treatment approach delivers radiation at UHDR, demanding careful adoption of QA protocols and procedures. A comprehensive understanding of beam properties and dosimetry consistency is vital to ensure the safe and effective delivery of FLASH-RT. PURPOSE: To develop a comprehensive pre-treatment QA program for cyclotron-based proton pencil beam scanning (PBS) FLASH-RT. Establish appropriate tolerances for QA items based on this study's outcomes and TG-224 recommendations. METHODS: A 250 MeV proton spot pattern was designed and implemented using UHDR with a 215nA nozzle beam current. The QA pattern that covers a central uniform field area, various spot spacings, spot delivery modes and scanning directions, and enabling the assessment of absolute, relative and temporal dosimetry QA parameters. A strip ionization chamber array (SICA) and an Advanced Markus chamber were utilized in conjunction with a 2 cm polyethylene slab and a range (R80) verification wedge. The data have been monitored for over 3 months. RESULTS: The relative dosimetries were compliant with TG-224. The variations of temporal dosimetry for scanning speed, spot dwell time, and spot transition time were within ± 1 mm/ms, ± 0.2 ms, and ± 0.2 ms, respectively. While the beam-to-beam absolute output on the same day reached up to 2.14%, the day-to-day variation was as high as 9.69%. High correlation between the absolute dose and dose rate fluctuations were identified. The dose rate of the central 5 × 5 cm2 field exhibited variations within 5% of the baseline value (155 Gy/s) during an experimental session. CONCLUSIONS: A comprehensive QA program for FLASH-RT was developed and effectively assesses the performance of a UHDR delivery system. Establishing tolerances to unify standards and offering direction for future advancements in the evolving FLASH-RT field.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38879087

RESUMO

PURPOSE: This study aimed to investigate a dose rate optimization framework based on the spot-scanning patterns to improve ultrahigh-dose-rate coverage of critical organs at risk (OARs) for proton pencil beam scanning (PBS) FLASH radiation therapy (ultrahigh dose-rate (often referred to as >40 Gy per second) delivery) and present implementation of a genetic algorithm (GA) method for spot sequence optimization to achieve PBS FLASH dose rate optimization under relatively low nozzle beam currents. METHODS AND MATERIALS: First, a multifield FLASH plan was developed to meet all the dosimetric goals and optimal FLASH dose rate coverage by considering the deliverable minimum monitor unit constraint. Then, a GA method was implemented into the in-house treatment platform to maximize the dose rate by exploring the best spot delivery sequence. A phantom study was performed to evaluate the effectiveness of the dose rate optimization. Then, 10 consecutive plans for patients with lung cancer previously treated using PBS intensity-modulated proton therapy were optimized using 45 GyRBE in 3 fractions for both transmission and Bragg peak FLASH radiation therapy for further validation. The spot delivery sequence of each treatment field was optimized using this GA. The ultrahigh-dose-rate-volume histogram and dose rate coverage V40GyRBE/s were investigated to assess the efficacy of dose rate optimization quantitatively. RESULTS: Using a relatively low monitor unit/spot of 150, corresponding to a nozzle beam current of 65 nA, the FLASH dose rate ratio V40GyRBE/s of the OAR contour of the core was increased from 0% to ∼60% in the phantom study. In the patients with lung cancer, the ultrahigh-dose-rate coverage V40GyRBE/s was improved from 15.2%, 15.5%, 17.6%, and 16.0% before the delivery sequence optimization to 31.8%, 43.5%, 47.6%, and 30.5% after delivery sequence optimization in the lungs-GTV (gross tumor volume), spinal cord, esophagus, and heart (for all, P < .001). When the beam current increased to 130 nA, V40GyRBE/s was improved from 45.1%, 47.1%, 51.2%, and 51.4% to 65.3%, 83.5%, 88.1%, and 69.4% (P < .05). The averaged V40GyRBE/s for the target and OARs increased from 12.9% to 41.6% and 46.3% to 77.5% for 65 and 130 nA, respectively, showing significant improvements based on a clinical proton system. After optimizing the dose rate for the Bragg peak FLASH technique with a beam current of 340 nA, the V40GyRBE/s values for the lung GTV, spinal cord, esophagus, and heart were increased by 8.9%, 15.8%, 22%, and 20.8%, respectively. CONCLUSIONS: An optimal plan quality can be maintained as the spot delivery sequence optimization is a separate independent process after the plan optimization. Both the phantom and patient results demonstrated that novel spot delivery sequence optimization can effectively improve the ultrahigh-dose-rate coverage for critical OARs, which can potentially be applied in clinical practice for better OARs-sparing efficacy.

4.
Ageing Res Rev ; 99: 102355, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942201

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of Governor vessel acupuncture (GV Ac) in treating post-stroke cognitive impairment (PSCI). METHODS: There was a total of seven databases examined. Four English databases (Cochrane Library, PubMed, Embase, and Medline) and three Chinese databases (Chinese National Knowledge Infrastructure (CNKI), Chinese Science and Technology Periodical Databases (VIP), and Wan Fang Database) contain all randomized controlled trials (RCTs) comparing Governor vessel acupuncture to other treatments or none acupuncture for PSCI. The exact dates for the search period are from January 1, 2000, to January 1, 2023.Two researchers independently reviewed the literature, gathered RCT data, and performed statistical analysis. All data were analyzed using Review Manager software (Rev Man) 5.3. RESULTS: This meta-analysis includes a total of 39 trials with 2044 patients. There were 1022 participants in each of the test and control groups. Following 12-120 days of acupuncture treatment, a meta-analysis revealed that the treatment groups (GV Ac combined with conventional treatment groups) significantly increased their scores on the Curative ratio (OR = 3.00, 95 %CI = 2.37-3.79, P = 0.98, I² = 0 %), Montreal Cognitive Assessment (MoCA)(MD = 1.82, 95 %CI = 1.60-2.03, P = 0.11, I² = 25 %), Mini-Mental State Examination (MMSE)(MD = 2.18, 95 %CI = 1.64-2.72, P<0.005, I² = 92 %), and Activity of Daily Living (ADL)(MD = 5.99, 95 %CI = 5.33-6.64, P = 0.19, I² = 26 %). CONCLUSION: The results suggested that acupuncture on points of the Governor vessel enhanced cognitive function in stroke survivors.

5.
Heliyon ; 10(9): e30522, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38765166

RESUMO

Objective: Acupuncture as an alternative therapy for post-stroke cognitive impairment (PSCI) has emerged as a research focus. The inclusion of additional external treatments in many previous studies prevents a clear, direct assessment of acupuncture's impact on PSCI. In order to prevent patients from developing hypersensitivity to other treatments and misinterpreting acupuncture's true therapeutic value, this study establish stricter intervention criteria and exclude therapies beyond acupuncture. The review aimed to offering a clearer evaluation of acupuncture's efficacy and safety in PSCI treatment. Methods: This research involved a comprehensive search for randomized controlled trials (RCTs) across eight databases, adhering to the Cochrane Systematic Reviewer's Handbook 5.1.0 for risk-of-bias and quality assessments. A meta-analysis was conducted using RevMan 5.3 software. Results: The inclusion of 18 publications, totaling 1361 patients, was achieved. The meta-analysis demonstrated a significantly higher overall efficacy of acupuncture for PSCI compared to controls (OR = 4.06, 95 % CI 2.86-5.76, Z = 7.82). Notable statistical differences were observed in the Montreal Cognitive Assessment scores (MD = 2.32, 95 % CI 1.68-2.97, Z = 7.10) and the Mini-Mental State Examination scores (MD = 2.02, 95 % CI 1.06-2.98, Z = 4.13) between the groups. Improvements in the Barthel Index scores were noted for the experimental group (MD = 5.70, 95 % CI 4.68-6.72, Z = 10.92). Conclusion: Integrating acupuncture with Western medications offers significant benefits for treating PSCI over Western medications alone. However, the long-term efficacy of acupuncture in PSCI treatment and its potential in reducing recurrence rates remain undetermined. Further high-standard RCTs are essential to explore acupuncture's effectiveness in PSCI treatment more thoroughly.

6.
Front Oncol ; 14: 1374258, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590650

RESUMO

Introduction: Invisible ink tattoos (IITs) avoid cosmetic permanence of visible ink tattoos (VITs) while serving as more reliable landmarks for radiation setup than tattooless setups. This trial evaluated patient-reported preference and feasibility of IIT implementation. Methods and materials: In an IRB-approved, single institution, prospective trial, patients receiving proton therapy underwent IIT-based treatment setup. A survey tool assessed patient preference on tattoos using a Likert scale. Matched patients treated using our institutional standard tattooless setup were identified; treatment times and image guidance requirements were evaluated between tattooless and IIT-based alignment approaches. Distribution differences were estimated using Wilcoxon rank-sum tests or Chi-square tests. Results: Of 94 eligible patients enrolled, median age was 58 years, and 58.5% were female. Most common treatment sites were breast (18.1%), lung (17.0%) and pelvic (14.9%). Patients preferred to receive IITs versus VITs (79.8% pre-treatment and 75.5% post-treatment, respectively). Patients were willing to travel farther from home to avoid VITs versus IITs (p<0.01). Females were willing to travel (45.5% vs. 23.1%; p=0.04) and pay additional money to avoid VITs (34.5% vs. 5.1%; p<0.01). Per-fraction average +treatment time and time from on table/in room to first beam were shorter with IIT-based vs. tattooless setup (12.3min vs. 14.1min; p=0.04 and 24.1min vs. 26.2min; p=0.02, respectively). Discussion: In the largest prospective trial on IIT-based radiotherapy setup to date, we found that patients prefer IITs to VITs. Additionally, IIT-based alignment is an effective and efficient strategy in comparison with tattooless setup. Standard incorporation of IITs for patient setup should be strongly considered.

7.
Int J Radiat Oncol Biol Phys ; 119(1): 306-307, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38631743
8.
Artigo em Inglês | MEDLINE | ID: mdl-38499254

RESUMO

PURPOSE: One main advantage of proton therapy versus photon therapy is its precise radiation delivery to targets without exit dose, resulting in lower dose to surrounding healthy tissues. This is critical, given the proximity of head and neck tumors to normal structures. However, proton planning requires careful consideration of factors, including air-tissue interface, anatomic uncertainties, surgical artifacts, weight fluctuations, rapid tumor response, and daily variations in setup and anatomy, as these heterogeneities can lead to inaccuracies in targeting and creating unwarranted hotspots to a greater extent than photon radiation. In addition, the elevated relative biological effectiveness at the Bragg peak's distal end can also increase hot spots within and outside the target area. METHODS AND MATERIALS: The purpose of this study was to evaluate for a difference in positron emission tomography (PET) standard uptake value (SUV) after definitive treatment, between intensity modulated proton therapy (IMPT) and intensity modulated photon therapy (IMRT). In addition, we compared the biologic dose between PET areas of high and low uptake within the clinical target volume-primary of patients treated with IMPT. This work is assuming that the greater SUV may potentially result in greater toxicities. For the purposes of this short communication, we are strictly focusing on the SUV and do not have correlation with toxicity outcomes. To accomplish this, we compared the 3- and 6-month posttreatment fluorodeoxyglucose PET scans for 100 matched patients with oropharyngeal cancer treated definitively without surgery using either IMPT (n = 50) or IMRT (n = 50). RESULTS: Our study found a significant difference in biologic dose between the high- and low-uptake regions on 3-month posttreatment scans of IMPT. However, this difference did not translate to a significant difference in PET uptake in the clinical target volume-primary at 3 and 6 months' follow-up between patients who received IMPT versus IMRT. CONCLUSIONS: Studies have proposed that proton's greater relative biological effectiveness at the Bragg peak could lead to tissue inflammation. Our study did not corroborate these findings. This study's conclusion underscores the need for further investigations with ultimate correlation with clinical toxicity outcomes.

9.
Phys Imaging Radiat Oncol ; 29: 100535, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38298885

RESUMO

Background and purpose: Many 4D particle therapy research concepts have been recently translated into clinics, however, remaining substantial differences depend on the indication and institute-related aspects. This work aims to summarise current state-of-the-art 4D particle therapy technology and outline a roadmap for future research and developments. Material and methods: This review focused on the clinical implementation of 4D approaches for imaging, treatment planning, delivery and evaluation based on the 2021 and 2022 4D Treatment Workshops for Particle Therapy as well as a review of the most recent surveys, guidelines and scientific papers dedicated to this topic. Results: Available technological capabilities for motion surveillance and compensation determined the course of each 4D particle treatment. 4D motion management, delivery techniques and strategies including imaging were diverse and depended on many factors. These included aspects of motion amplitude, tumour location, as well as accelerator technology driving the necessity of centre-specific dosimetric validation. Novel methodologies for X-ray based image processing and MRI for real-time tumour tracking and motion management were shown to have a large potential for online and offline adaptation schemes compensating for potential anatomical changes over the treatment course. The latest research developments were dominated by particle imaging, artificial intelligence methods and FLASH adding another level of complexity but also opportunities in the context of 4D treatments. Conclusion: This review showed that the rapid technological advances in radiation oncology together with the available intrafractional motion management and adaptive strategies paved the way towards clinical implementation.

10.
Cancers (Basel) ; 16(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38398188

RESUMO

Bragg peak FLASH radiotherapy (RT) uses a distal tracking method to eliminate exit doses and can achieve superior OAR sparing. This study explores the application of this novel method in stereotactic body radiotherapy prostate FLASH-RT. An in-house platform was developed to enable intensity-modulated proton therapy (IMPT) planning using a single-energy Bragg peak distal tracking method. The patients involved in the study were previously treated with proton stereotactic body radiotherapy (SBRT) using the pencil beam scanning (PBS) technique to 40 Gy in five fractions. FLASH plans were optimized using a four-beam arrangement to generate a dose distribution similar to the conventional opposing beams. All of the beams had a small angle of two degrees from the lateral direction to increase the dosimetry quality. Dose metrics were compared between the conventional PBS and the Bragg peak FLASH plans. The dose rate histogram (DRVH) and FLASH metrics of 40 Gy/s coverage (V40Gy/s) were investigated for the Bragg peak plans. There was no significant difference between the clinical and Bragg peak plans in rectum, bladder, femur heads, large bowel, and penile bulb dose metrics, except for Dmax. For the CTV, the FLASH plans resulted in a higher Dmax than the clinical plans (116.9% vs. 103.3%). For the rectum, the V40Gy/s reached 94% and 93% for 1 Gy dose thresholds in composite and single-field evaluations, respectively. Additionally, the FLASH ratio reached close to 100% after the application of the 5 Gy threshold in composite dose rate assessment. In conclusion, the Bragg peak distal tracking method can yield comparable plan quality in most OARs while preserving sufficient FLASH dose rate coverage, demonstrating that the ultra-high dose technique can be applied in prostate FLASH SBRT.

11.
J Thorac Dis ; 16(1): 65-80, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38410598

RESUMO

Background: Asthma is characterized by airway hyperresponsiveness, reversible airway obstruction, and chronic airway inflammation. It is the most common chronic disease in childhood. However, the diagnosis of childhood asthma remains challenging, and there is an urgent need to develop new diagnostic methods. Methods: To identify biomarkers of asthma in children, we adopted the Orbitrap-based data-independent acquisition (DIA) mass spectrometry proteomics method to analyze the serum proteomic signatures of children with acute asthma and convalescent children. Results: We identified 747 proteins in 46 serum samples and 50 differentially expressed proteins (DEPs) that distinguished between asthmatic and healthy children. Next, functional enrichment analysis of the DEPs was conducted, it was indicated that the DEPs were significantly enriched in immune-related and function terms and pathways. Furthermore, we performed statistical analysis and identified MMP14, ABHD12B, PCYOX1, LTBP1, CFHR4, APOA1, IGHG4, ANG and IGFALS proteins as the diagnostic biomarker candidates. Ultimately, a promising asthma diagnostic model for preschool children based on IGFALS was built and evaluated. The area under the curve (AUC) of the IGFALS model was 0.959. Conclusions: In this study, the DIA proteome strategy was used and the largest number of proteins of asthmatic children serum proteomics was identified. The proteomics results showed that the DEPs play the central role of the inflammation-immune mechanism in asthma pathogenesis, suggesting that these proteins may be used in asthma diagnosis, prognosis, or therapy, and suggested biomarkers for asthma of preschool children. In conclusion, our results provide insight into the pathophysiology of asthma. We believe that the diagnostic model will facilitate clinical decision-making regarding asthma in preschool children.

12.
Cancers (Basel) ; 16(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38275907

RESUMO

Our study aims to quantify the impact of spectral separation on achieved theoretical prediction accuracy of proton-stopping power when the volume discrepancy between calibration phantom and scanned object is observed. Such discrepancy can be commonly seen in our CSI pediatric patients. One of the representative image-domain DECT models is employed on a virtual phantom to derive electron density and effective atomic number for a total of 34 ICRU standard human tissues. The spectral pairs used in this study are 90 kVp/140 kVp, without and with 0.1 mm to 0.5 mm additional tin filter. The two DECT images are reconstructed via a conventional filtered back projection algorithm (FBP) on simulated noiseless projection data. The best-predicted accuracy occurs at a spectral pair of 90 kVp/140 kVp with a 0.3 mm tin filter, and the root-mean-squared average error is 0.12% for tissue substitutes. The results reveal that the selected image-domain model is sensitive to spectral pair deviation when there is a discrepancy between calibration and scanning conditions. This study suggests that an optimization process may be needed for clinically available DECT scanners to yield the best proton-stopping power estimation.

13.
Med Dosim ; 49(1): 19-24, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37914563

RESUMO

To assess the performance of a knowledge-based planning (KBP) model for generating intensity-modulated proton therapy (IMPT) treatment plans as part of an adaptive radiotherapy (ART) strategy for patients with high-risk prostate cancer. A knowledge-based planning (KBP) model for proton adaptive treatment plan generation was developed based on thirty patient treatment plans utilizing RapidPlanTM PT (Varian Medical Systems, Palo Alto, CA). The model was subsequently validated using an additional eleven patient cases. All patients in the study were administered a prescribed dose of 70.2 Gy to the prostate and seminal vesicle (CTV70.2), along with 46.8 Gy to the pelvic lymph nodes (CTV46.8) through simultaneous integrated boost (SIB) technique. To assess the quality of the validation knowledge-based proton plans (KBPPs), target coverage and organ-at-risk (OAR) dose-volume constraints were compared against those of clinically used expert plans using paired t-tests. The KBP model training statistics (R2) (mean ± SD, 0.763 ± 0.167, range, 0.406 to 0.907) and χ² values (1.162 ± 0.0867, 1.039-1.253) indicate acceptable model training quality. Moreover, the average total treatment planning optimization and calculation time for adaptive plan generation is approximately 10 minutes. The CTV70.2 D98% for the KBPPs (mean ± SD, 69.1 ± 0.08 Gy) and expert plans (69.9 ± 0.04 Gy) shows a significant difference (p < 0.05) but are both within 1.1 Gy of the prescribed dose which is clinically acceptable. While the maximum dose for some organs-at-risk (OARs) such as the bladder and rectum is generally higher in the KBPPs, the doses still fall within clinical constraints. Among all the OARs, most of them received comparable results to the expert plan, except the cauda equina Dmax, which shows statistical significance and was lower in the KBPPs than in expert plans (48.5 ± 0.06 Gy vs 49.3 ± 0.05 Gy). The generated KBPPs were clinically comparable to manually crafted plans by expert treatment planners. The adaptive plan generation process was completed within an acceptable timeframe, offering a quick same-day adaptive treatment option. Our study supports the integration of KBP as a crucial component of an ART strategy, including maintaining plan consistency, improving quality, and enhancing efficiency. This advancement in speed and adaptability promises more precise treatment in proton ART.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Masculino , Humanos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Próstata/radioterapia
14.
Med Dosim ; 49(1): 25-29, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38040549

RESUMO

This study explores the feasibility and potential dosimetric and time efficiency benefit of proton Pencil Beam Scanning (PBS) craniospinal irradiation with a single posterior-anterior (SPA) brain field. The SPA approach was compared to our current clinical protocol using Bilateral Posterior Oblique brain fields (BPO). Ten consecutive patients were simulated in the head-first supine position on a long BOS frame and scanned using 3 mm CT slice thickness. A customized thermoplastic mask immobilized the patient's head, neck, and shoulders. A vac-lock was used to secure the legs. PBS proton plans were robustly optimized with 3mm setup errors and 3.5% range uncertainties in the Eclipse V15.6 treatment planning system (n = 12 scenarios). In order to achieve a smooth gradient dose match at the junction area, at least 5 cm overlap region was maintained between the segments and 5 mm uncertainty along the cranial-cauda direction was applied to each segment independently as additional robust optimization scenarios. The brain doses were planned by SPA or BPO fields. All spine segments were planned with a single PA field. Dosimetric differences between the BPO and SPA approaches were compared, and the treatment efficiency was analyzed according to timestamps of beam delivery. Results: The maximum brain dose increases to 111.1 ± 2.1% for SPA vs. 109.0 ± 1.7% for BPO (p < 0.01). The dose homogeneity index (D5/D95) in brain CTV was comparable between techniques (1.037 ± 0.010 for SPA and 1.033 ± 0.008 for BPO). Lens received lower maximum doses by 2.88 ± 1.58 Gy (RBE) (left) and 2.23 ± 1.37 Gy (RBE) (right) in the SPA plans (p < 0.01). No significant cochlea dose change was observed. SPA reduced the treatment time by more than 4 minutes on average and ranged from 2 to 10 minutes, depending on the beam waiting and allocation time. SPA is dosimetrically comparable to BPO, with reduced lens doses at the cost of slightly higher dose inhomogeneity and hot spots. Implementation of SPA is feasible and can help to improve the treatment efficiency of PBS CSI treatment.


Assuntos
Radiação Cranioespinal , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Prótons , Radiação Cranioespinal/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Encéfalo , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos
15.
Med Phys ; 51(2): 786-798, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38103260

RESUMO

BACKGROUND: The first clinical trials to assess the feasibility of FLASH radiotherapy in humans have started (FAST-01, FAST-02) and more trials are foreseen. To increase comparability between trials it is important to assure treatment quality and therefore establish a standard for machine quality assurance (QA). Currently, the AAPM TG-224 report is considered as the standard on machine QA for proton therapy, however, it was not intended to be used for ultra-high dose rate (UHDR) proton beams, which have gained interest due to the observation of the FLASH effect. PURPOSE: The aim of this study is to find consensus on practical guidelines on machine QA for UHDR proton beams in transmission mode in terms of which QA is required, how they should be done, which detectors are suitable for UHDR machine QA, and what tolerance limits should be applied. METHODS: A risk assessment to determine the gaps in the current standard for machine QA was performed by an international group of medical physicists. Based on that, practical guidelines on how to perform machine QA for UHDR proton beams were proposed. RESULTS: The risk assessment clearly identified the need for additional guidance on temporal dosimetry, addressing dose rate (constancy), dose spillage, and scanning speed. In addition, several minor changes from AAPM TG-224 were identified; define required dose rate levels, the use of clinically relevant dose levels, and the use of adapted beam settings to minimize activation of detector and phantom materials or to avoid saturation effects of specific detectors. The final report was created based on discussions and consensus. CONCLUSIONS: Consensus was reached on what QA is required for UHDR scanning proton beams in transmission mode for isochronous cyclotron-based systems and how they should be performed. However, the group discussions also showed that there is a lack of high temporal resolution detectors and sufficient QA data to set appropriate limits for some of the proposed QA procedures.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Ciclotrons , Prótons , Consenso , Radiometria , Dosagem Radioterapêutica
16.
J Radiosurg SBRT ; 9(1): 63-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38029007

RESUMO

Purpose: Stereotactic body proton therapy (SBPT) is an emerging treatment strategy for lung tumors that aims to combine the excellent local control benefits of ultra-hypofractionation with the physical advantages of protons, which reduce the integral dose to organs at risk (OARs) compared to photons. To date, however, very little data delivering SBPT in 5 or fewer fractions to lung tumors have been reported. Given that photon stereotactic body radiation therapy can struggle to deliver ablative doses to high-risk tumors (i.e., central/ultra-central location, prior in-field radiation, tumor size >5 cm, or the presence of severe pulmonary comorbidities) while adhering to OAR dose constraints, we hypothesized that SBPT would be an effective alternative for patients with high-risk tumors. Methods and Materials: Twenty-seven high-risk patients with 29 lung tumors treated with SBPT at the New York Proton Center between December 2019 and November 2022 were retrospectively identified. Patients were divided into three major subgroups: early-stage non-small cell lung cancer (NSCLC), locally recurrent NSCLC, and metastatic cancer from lung cancer or other histologies. Patient characteristics were reported using descriptive statistics, actuarial methods were used to quantify disease control rates, and toxicities were scored using CTCAE v 5.0. Results: The most common high-risk indications for SBPT were central/ultra-central tumor location (69.0%), severe COPD (48.1%), reirradiation (44.4%), significant pulmonary fibrosis (22.2%), and large tumor size > 5 cm (18.5%). In total, 96.6% of tumors were fully covered by the prescription dose without compromising target coverage. Three-year actuarial rates of local control for early-stage NSCLC, locally recurrent NSCLC, and metastatic patients were 89%, 100%, and 43%, respectively. Three-year actuarial rates of regional control were 89%, 67%, and 86%. Three-year actuarial rates of distant metastasis-free survival were 79%, 100%, and 0%. Two patients (7.4%), both of whom had clinically significant baseline interstitial lung disease and pre-treatment continuous oxygen demand, experienced grade ≥2 pulmonary toxicity (1 grade 3, 1 grade 5). There were no acute or late grade ≥2 toxicities related to esophagitis, cardiac injury, airway injury, pulmonary fibrosis, bronchopulmonary hemorrhage or brachial plexopathy. Conclusions: In the largest study of proton SBRT reported to date, SBPT has a favorable toxicity profile while being an effective approach for treating most high-risk tumors without requiring dose de-escalation or compromising tumor coverage and warrants further investigation.

17.
J Radiosurg SBRT ; 9(1): 53-62, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38029008

RESUMO

This study presents the clinical experiences of the New York Proton Center in employing proton pencil beam scanning (PBS) for the treatment of lung stereotactic body radiation therapy. It encompasses a comprehensive examination of multiple facets, including patient simulation, delineation of target volumes and organs at risk, treatment planning, plan evaluation, quality assurance, and motion management strategies. By sharing the approaches of the New York Proton Center and providing recommendations across simulation, treatment planning, and treatment delivery, it is anticipated that the valuable experience will be provided to a broader proton therapy community, serving as a useful reference for future clinical practice and research endeavors in the field of stereotactic body proton therapy for lung tumors.

18.
J Radiosurg SBRT ; 9(1): 17-32, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38029014

RESUMO

Stereotactic body radiation therapy (SBRT) has emerged as a standard treatment approach for early-stage lung cancer and intrathoracic oligometastatic or oligoprogressive disease. While local control is often excellent with this modality when delivered with photon therapy, toxicities for select patients can be significant. Proton therapy offers a unique opportunity to widen the therapeutic window when treating patients with thoracic malignancies requiring or benefitting from ultra-high doses per fraction. Thoracic proton SBRT may be particularly beneficial in cases requiring dose escalation, for tumors >5 cm, for central or ultra-central tumors, for reirradiation, in patients with interstitial lung diseases, and when combining radiation with immunotherapy. These clinical indications are detailed, along with supporting literature and clinical recommendations. Other considerations, future directions and potential benefits of proton SBRT, including sparing lymphocytes, when delivered as intensity-modulated proton therapy or as FLASH, and for the treatment of locally advanced non-small cell lung cancer or in patients with homologous recombination repair deficiencies, are also discussed.

19.
Cancers (Basel) ; 15(20)2023 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-37894469

RESUMO

PURPOSE: The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy. METHODS: Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT. RESULTS: The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The Dmax of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%. CONCLUSION: The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.

20.
Cancers (Basel) ; 15(18)2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37760528

RESUMO

Bragg peak FLASH-RT can deliver highly conformal treatment and potentially offer improved normal tissue protection for radiotherapy patients. This study focused on developing ultra-high dose rate (≥40 Gy × RBE/s) intensity-modulated proton therapy (IMPT) for hypofractionated treatment of early-stage breast cancer. A novel tracking technique was developed to enable pencil beaming scanning (PBS) of single-energy protons to adapt the Bragg peak (BP) to the target distally. Standard-of-care PBS treatment plans of consecutively treated early-stage breast cancer patients using multiple energy layers were reoptimized using this technique, and dose metrics were compared between single-energy layer BP FLASH and conventional IMPT plans. FLASH dose rate coverage by volume (V40Gy/s) was also evaluated for the FLASH sparing effect. Distal tracking can precisely stop BP at the target distal edge. All plans (n = 10) achieved conformal IMPT-like dose distributions under clinical machine parameters. No statistically significant differences were observed in any dose metrics for heart, ipsilateral lung, most ipsilateral breast, and CTV metrics (p > 0.05 for all). Conventional plans yielded slightly superior target and skin dose uniformities with 4.5% and 12.9% lower dose maxes, respectively. FLASH-RT plans reached 46.7% and 61.9% average-dose rate FLASH coverage for tissues receiving more than 1 and 5 Gy plan dose total under the 250 minimum MU condition. Bragg peak FLASH-RT techniques achieved comparable plan quality to conventional IMPT while reaching adequate dose rate ratios, demonstrating the feasibility of early-stage breast cancer clinical applications.