Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 24(1): 407, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37217909

RESUMO

BACKGROUND: Intermediate vertebral collapse is a newly discovered complication of consecutive two-level anterior cervical discectomy and fusion (ACDF). There have been no analytical studies related to the effects of endplate defects on the biomechanics of the intermediate vertebral bone after ACDF. This study aimed to compare the effects of endplate defects on the intermediate vertebral bone biomechanics in the zero-profile (ZP) and cage-and-plate (CP) methods of consecutive 2-level ACDF and to determine whether collapse of the intermediate vertebra is more likely to occur using ZP. METHODS: A three-dimensional finite element (FE) model of the intact cervical spine (C2-T1) was constructed and validated. The intact FE model was then modified to build ACDF models and imitate the situation of endplate injury, establishing two groups of models (ZP, IM-ZP and CP, IM-ZP). We simulated cervical motion, such as flexion, extension, lateral bending and axial rotation, and compared the range of motion (ROM), upper and lower endplate stress, fusion fixation device stress, C5 vertebral body stress, intervertebral disc internal pressure (intradiscal pressure, or IDP) and the ROM of adjacent segments in the models. RESULTS: There was no significant difference between the IM-CP model and the CP model in the ROM of the surgical segment, upper and lower endplate stress, fusion fixation device stress, C5 vertebral body stress, IDP, or ROM of the adjacent segments. Compared with the CP model, the endplate stress of the ZP model is significantly higher in the flexion, extension, lateral bending and axial rotation conditions. Compared with the ZP model, endplate stress, screw stress, C5 vertebral stress and IDP in IM-ZP were significantly increased under flexion, extension, lateral bending and axial rotation conditions. CONCLUSIONS: Compared to consecutive 2-level ACDF using CP, collapse of the intermediate vertebra is more likely to occur using ZP due to its mechanical characteristics. Intraoperative endplate defects of the anterior lower margin of the middle vertebra are a risk factor leading to collapse of the middle vertebra after consecutive 2-level ACDF using ZP.


Assuntos
Disco Intervertebral , Fusão Vertebral , Humanos , Análise de Elementos Finitos , Fusão Vertebral/métodos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Discotomia/métodos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos
2.
Digit Health ; 9: 20552076231173562, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37163171

RESUMO

Background: Since entering the 21st century, there has been an increasing interest in minimally invasive surgery for spinal diseases, which has led to the continued development of minimally invasive spine surgery (MISS), with major breakthroughs in technology and technical skills. However, in recent years, there is little relevant research using bibliometrics to analyze the field of MISS research. The purpose of this study is to sort out the publication situation and topic trends of articles in the field of MISS research from the perspective of bibliometrics. Methods: The articles and reviews related to MISS from 2000 to 2022 were retrieved and downloaded from the Web of Science Core Collection (WOSCC). Visualization and knowledge mapping were performed using three bibliometric tools, including online bibliometric platform, CiteSpace and VOSviewer software. Curve fitting and correlation analysis were performed using Microsoft Excel software. The global research publication output, contributions of countries, institutions, authors, and journals, average citations per item (ACI), Hirsch index (H-index), research hot keywords, etc., in this field were analyzed. Results: A total of 2384 papers were retrieved, including 2135 original papers and 249 review papers. In the past 22 years, the number of annual publications of MISS research has shown a steady growth trend. China contributed the most papers, and the United States ranked second, but the United States had the highest total citations, and H-index value. The most prolific institutions were Soochow University, Capital Medical University and Wooridul Spine Hospital. In this field, Professors Lee SH, Ahn Y and Yang HL have made significant achievements. However, there is relatively little international collaboration between institutions or researchers. World Neurosurgery is the most published journal on MISS research. According to the keyword co-occurrence analysis, recent keywords mainly focus on researches on minimally invasive modalities, techniques and prognosis, while on the keyword analysis of the ongoing bursts, percutaneous transforaminal endoscopic discectomy, lumbar diskectomy, spinal stenosis, recompression, diskectomy, endoscopic spine surgery, laminectomy, transforaminal lumbar interbody fusion, etc., will likely continue to be a research hotspot in the near future. Conclusion: Looking at the temporal trend in the number of publications per year, the number of publications for the MISS study will increase in the near future. China has the highest number of publications, but the US has the highest quality publications. International cooperation needs to be further strengthened. Our findings can provide useful information for the academic community and identify possible research fronts and hotspots in the coming years.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36110184

RESUMO

Background: With the aging of the population, the prevalence of IVDD increases preoperatively. How to better treat IVDD has become an important clinical issue. Deer antlers proved to have a great effect on the treatment of IVDD in many studies, but the molecular mechanism has not been clarified. Objective: To investigate the molecular mechanism and target of deer antlers in the treatment of IVDD. Methods: Compounds from deer antlers were collected and targets were predicted using HERB, TCMSP, TCMID, SwissADME, and SwissTargetPrediction. Collection of disease targets for IVDD was done using GeneCards, TTD, DrugBank, DisGeNET, and OMIM. Cytoscape 3.7.2, AutoDock Vina (v1.1.2), and R software were used for data analysis and the construction of network diagrams. Results: A total of 5 active compounds from deer antlers were screened and 104 therapeutic targets were predicted. A total of 1023 IVDD disease targets were collected. Subsequently, PPI network prediction analysis was performed for disease and treatment targets, and 112 core targets were collected after screening. After obtaining the core target, we used the clusterProfiler software package of R software to carry out GO and KEGG enrichment analyses for the core target and plot the bubble maps. According to the GO enrichment results, the main biological processes of IVDD treatment by deer antlers lie in the rhythmic process, mRNA catabolic process, and G1/S transition of the mitotic cell cycle. KEGG results were mainly related to the PI3K-Akt signaling pathway, thyroid hormone signaling pathway, and Notch signaling pathway. Molecular docking results showed that estrone had the best docking results on ESR1. Conclusion: Deer antlers are rich in various compounds that can prevent the development of IVDD by upregulating the PI3K-Akt signaling pathway and Notch signaling pathway. Its key compounds estradiol and estrone can reduce the inflammatory response and oxidative stress in tissues and organs, thus slowing down the progression of IVDD. Estrone, the active compound in deer antlers, was found by molecular docking to have good results against ESR1, the target of the disease, which may be a potential site for drug therapy.

4.
World Neurosurg ; 165: e175-e190, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35688369

RESUMO

OBJECTIVE: The objective of this study was to describe a new potential complication, collapse in the middle cervical vertebra of consecutive 2-level anterior cervical discectomy and fusion (ACDF), and discuss its possible mechanism. METHODS: Clinical and radiologic outcome data from 27 consecutive 2-level ACDF patients using zero-profile devices were collected at 1, 3, 6, and 12 months postoperatively, as well as the last follow-up. Dysphagia was assessed using the Bazaz score, and clinical outcomes were analyzed using the neck disability index and Japanese Orthopaedic Association score. Radiographic evaluation included measurements of the overall and surgical segment curvature, identification of collapse, and assessment of the ratio of anterior height and wedge of the upper, middle, and lower vertebrae in the surgical segment. RESULTS: The application of zero-profile devices to treat consecutive 2-level cervical spondylosis mostly resulted in good midterm clinical outcomes. Surprisingly, as evidenced by the significantly decreased anterior height and wedge ratio of the middle cervical vertebra, collapse was noted immediately in the middle vertebra in 4 patients at 1 month (n = 3) and 3 months (n = 1). The collapse increased for no more than 6 months, and there was no deterioration of clinical and radiological outcomes at the last follow-up. CONCLUSIONS: Collapse in the middle cervical vertebra of consecutive 2-level ACDF with the application of zero-profile devices can occur in the early postoperative period, which may be due to axial stress concentration and blood supply damage in the middle cervical vertebral body.


Assuntos
Fusão Vertebral , Espondilose , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia/métodos , Seguimentos , Humanos , Estudos Retrospectivos , Fusão Vertebral/métodos , Espondilose/diagnóstico por imagem , Espondilose/cirurgia , Resultado do Tratamento
5.
Zhongguo Gu Shang ; 35(5): 435-41, 2022 May 25.
Artigo em Chinês | MEDLINE | ID: mdl-35535531

RESUMO

OBJECTIVE: To explore the clinical efficacy of percutaneous pedicle screw short segment internal fixation with or without the intermediate screw in the treatment of Magerl A3 thoracolumbar fractures with low bone mineral density. METHODS: Patients with Magerl A3 thoracolumbar fracture underwent percutaneous pedicle screw short segment internal fixation from January 2017 to July 2020 were retrospectively analyzed, 93 cases met the diagnosis and inclusion criteria, 9 cases were excluded according to the exclusion criteria, and the remaining 84 cases obtained complete imaging follow-up data. There were 38 males and 46 females, the age ranged from 56 to 73 years old with an average of (64.78±7.12) years old, bone mineral density (BMD) ranged from 0.61 to 0.89 g/cm3 with an average of (0.73±0.14) g/cm3, the follow-up time was 11 to 25 months with an average of (17.58±6.12) months. There were 45 cases in group A with intermediate screw and 39 cases in group B without intermediate screw. The operation time and intraoperative blood loss were recorded, Oswestry Disability Index (ODI) and visual analogue scale (VAS) were used for clinical evaluation. The Cobb angle, vertebral wedge angle (VWA) and anterior vertebral body height (AVBH) were measured by X-ray after the operation. The corrected loss of the above parameters was calculated. RESULTS: There were 5 cases of screw loosening in 84 patients (2 cases in group A and 3 cases in group B, P>0.05). There were significant differences in operation time and intraoperative blood loss between two groups(P<0.01). Clinical effects of two groups were good, postoperative VAS and ODI after operation obviously improved, there was no significant difference between two groups during all follow-up periods (3 days, 1 month after operation and the final follow-up) (P>0.05). Three days after the operation, the image evaluations (Cobb angle, VWA and AVBH) were significantly improved (P<0.05), but significant reduction loss was observed in both groups at 1 month after the operation and at the final follow-up (P<0.05). At the final follow-up, the loss of Cobb angle, VWA and AVBH in group A were (5.26±4.18) °, (4.63±3.80) ° and (9.54±8.71)%, respectively;group B was (6.01±4.34) °, (6.55±6.21) ° and (11.67± 9.95)%, respectively;however, there was no significant difference in reduction loss between the two groups(P>0.05). CONCLUSION: Although the curative effect of the patients is satisfactory, the stability of the patients can not be improved by increasing the middle injured vertebra screw placement, the two groups of percutaneous short segment internal fixation can not resist the reduction loss of Magerl-A3 thoracolumbar fracture with low bone mineral density. Because the injured vertebra screw increases the operation time and intraoperative blood loss, it is not significant to use the intermediate screw for the elderly Magerl A3 thoracolumbar fractures with low bone mineral density.


Assuntos
Doenças Ósseas Metabólicas , Fraturas Ósseas , Parafusos Pediculares , Fraturas da Coluna Vertebral , Idoso , Perda Sanguínea Cirúrgica , Feminino , Fixação Interna de Fraturas , Humanos , Vértebras Lombares/lesões , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/lesões , Vértebras Torácicas/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...