Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 190(10): 415, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37750999

RESUMO

In recent years, electrochemiluminescence resonance energy transfer (ECL-RET) with low background signal and high specificity has attracted much attention among researchers. Herein, we established a novel ECL-RET biosensor for PML/RARα fusion gene detection. In this ECL-RET system, carbon dots (CDs) with low toxicity and prominent electrochemical activity were used as donor and Au@Ag2S core-shell nanoparticles (Au@Ag2S NPs) were employed as ECL acceptor. The Au@Ag2S NPs possessed a wide ultraviolet-visible (UV-vis) absorption spectrum between 500 nm and 700 nm, which completely overlapped with the ECL spectrum of CDs. Furthermore, the CDs-decorated poly-amidoamine/reduced graphene oxide (CDs/PAMAM/rGO) nanocomposites were prepared to improve the ECL signals and served as a substrate to stably load capture probe deoxyribonucleic acid (DNA). Based on the ECL-RET biosensing strategy, the Au@Ag2S NPs-labeled assistant probes and target DNA could pair with capture probes to form the sandwich-type DNA structure and the distance between donor and accepter was closed, leading to quenching of the ECL signal of CDs. The ECL-RET biosensor represented eminent analytical performance for PML/RARα fusion gene detection with a wide linear relationship from 5 fM to 500 pM and a low detection limit of 0.72 fM, which provided a novel technical means and theoretical basis for detection and diagnosis of acute promyelocytic leukemia.


Assuntos
Nanocompostos , Nanopartículas , Carbono , Transferência de Energia , DNA
2.
Biosens Bioelectron ; 238: 115583, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37573643

RESUMO

Since microRNAs (miRNAs) are predictors of tumorigenesis, accurate identification and quantification of miRNAs with highly similar sequences are expected to reflect tumor diagnosis and treatment. In this study, a highly selective and sensitive electrochemiluminescence (ECL) biosensor was constructed for miRNAs determination based on Y-shaped junction structure equipped with locked nucleic acids (LNA), graphene oxide-based nanocomposite to enrich luminophores, and conductive matrix. Specifically, two LNA-modified probes were designed for specific miRNA recognition, that is, a dual-amine functionalized hairpin capture probe and a signal probe. A Y-shaped DNA junction structure was generated on the electrode surface upon miRNA hybridizing across the two branches, so as to enhance the selectivity. Carbon quantum dots-polyethylene imine-graphene oxide (CQDs-PEI-GO) nanocomposites were developed to enrich luminophores CQDs, and thus enhancing the ECL intensity. For indirect signal amplification, an electrochemically activated poly(2-aminoterephthalic acid) (ATA) film decorated with gold nanoparticles was prepared on electrode as an effective matrix to accelerate the electron transfer. The fabricated ECL biosensor achieved sensitive determination of miRNA-222 with a limit-of-detection (LOD) as low as 1.95 fM (S/N = 3). Notably, Y-shaped junction structures equipped with LNA probes endowed ECL biosensor with salient single-base discrimination ability and anti-interference capacity. Overall, the proposed Y-shaped ECL biosensor has considerable promise for clinical biomarker determination.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , MicroRNAs , Pontos Quânticos , MicroRNAs/genética , Carbono/química , Pontos Quânticos/química , Ouro/química , Medições Luminescentes , Nanopartículas Metálicas/química , DNA/química , Sondas de Ácido Nucleico , Polietilenoimina/química , Técnicas Eletroquímicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...