Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arthrosc Tech ; 12(8): e1259-e1263, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37654865

RESUMO

Superior capsular reconstruction is a common treatment option for irreparable rotator cuffs. Arthroscopic surgery procedures mostly use anchor-based methods. However, difficulty in preoperative graft measurement and intra-articular knot-tying present an obstacle for most sport surgeons. Complementing the known advantages of the transosseous technique in rotator cuff repair, a feasible, economical arthroscopic transosseous superior capsular reconstruction technique is described in this Technical Note. This procedure results not only in similar fixation strength and stability and greater bone stock but also in greater cost effectiveness due to using fewer anchors. This Technical Note describes the procedure in detail and compares it with conventional procedures.

2.
Int J Mol Sci ; 23(16)2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-36012555

RESUMO

Peri-implantitis is defined as a bacterial infection-induced inflammation and suppuration of soft and hard tissues surrounding a dental implant. If bacteria further invade the alveolar bone, they can easily cause bone loss and even lead to the early failure of a dental implant surgery. In the present study, an 80SiO2-15CaO-5P2O5 mesoporous bioactive glass film system containing 1, 5, and 10 mol% of silver was prepared on titanium implant discs (MBG-Ag-coated Ti) using sol-gel and spin coating methods. The wettability and adhesion strength of the films were evaluated using contact angle measurements and adhesion strength tests, respectively. The phase composition, chemical bonding, morphology, and oxidation states of the films were analyzed via X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS). In vitro bioactivity analysis of the films was performed by immersion in a simulated body fluid (SBF) for 24 h. Disk diffusion tests were performed on the early colonizing bacteria Aggregatibacter actinomycetemcomitans and Streptococcus mutans to evaluate the antibacterial ability of the films. A silver-containing mesoporous bioactive glass film with excellent biocompatibility and antibacterial properties was successfully prepared.


Assuntos
Implantes Dentários , Prata , Antibacterianos/química , Antibacterianos/farmacologia , Vidro/química , Prata/farmacologia , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Titânio/química , Titânio/farmacologia , Difração de Raios X
3.
J Orthop Surg Res ; 17(1): 180, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35331270

RESUMO

BACKGROUND: For treating distal femur fractures, minimally invasive plating techniques with indirect reduction of the metadiaphysis while minimizing the damage to the peripheral soft tissue has gradually become the standard. However, all the current approaches use a straight or lazy curved incision adjacent to the patella or along the lateral side of the femur, which allows for easier proximal extension but increases the incision length. METHODS: In order to achieve a more physiological and esthetic outcome while leaving the metadiaphysis untouched, we developed an approach using a lambda-shaped incision, which sacrifices the potential for proximal extension but preserves much more peripheral soft tissue. Here, we describe our technique and our experience with it in 19 patients (12 men and 7 women). RESULTS: Fractures healing by first intention was observed in all patients. The postoperative knee range of motion can reach up to 90° in most of the patient. Clinically, 9 patients had excellent results, 6 had good results, 3 had fair results, and 2 had loss of follow-up. CONCLUSIONS: Our minimally invasive lambda-incision approach allows sufficient visual access to almost the entire joint surface, including the entire lateral femoral condyle, trochlear surface, and distal medial condyle, where reduction is required. The lambda incision provides a much larger window than that offered by a same-length straight incision. The vertical turn at the mid-patellar level parallels the skin crease and geniculate artery, reducing soft tissue damage and resulting in a smooth healing wound. Moreover, plate and distal screw insertion is easier than that through a straight incision. Because the metadiaphysis region is mostly left untouched, ideal fracture-healing environment is preserved.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Joelho/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur , Humanos , Masculino , Pessoa de Meia-Idade , Patela/cirurgia , Amplitude de Movimento Articular
4.
Arthrosc Tech ; 10(11): e2523-e2529, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34868857

RESUMO

Open transosseous repair was historically considered the gold-standard surgical solution for rotator cuff tears; however, with advancements in arthroscopic surgery, this procedure was largely replaced by anchor-based techniques. Yet, the ability of anchor-based techniques to achieve similar biomechanical fixation remains uncertain.In this article, we describe a reproducible, economical, arthroscopic anchorless transosseous rotator cuff repair technique that uses an Omega configuration. This technique involves two bone tunnels and four high-strength polyethylene sutures and is suitable for medium-to-large rotator cuff tears that would alternatively need multiple anchors. This procedure not only maximizes the tendon-footprint contact area without using any implanted device but also theoretically lowers the bone laceration rate and is cost effective. In the current Technical Note, the procedure is described in detail along with several tips and tricks. CLASSIFICATIONS: Level I, shoulder; Level II, rotator cuff.

5.
BMC Musculoskelet Disord ; 22(1): 748, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34461874

RESUMO

BACKGROUND: The fabella is a sesamoid bone in the posterolateral capsule of the human knee joint. In quadrupedal mammals, the fabella is believed to have a role similar to the patella in redirecting extension forces of the knee joint from one point to another. In bipeds, the fabella is not touching the back of the bent knee, and therefore the role in redirecting forces declines. Posterolateral knee pain can be associated with the irritation between the fabella and lateral femoral condyle, a phenomenon also known as fabella syndrome. In cases that are unresponsive to conservative management, surgical fabellectomy can be a successful treatment option. Among the surgical approaches, open resection is most commonly seen. There are also literature reporting arthroscopic-assisted open resection, but seldom mentioned the all-arthroscopic fabellectomy. CASE PRESENTATION: We present 3 patients with a long history (> 12 month) of posterolateral knee pain under suspicion of different pain origins. The diagnosis of fabella impingement was eventually made by ruling out of other causes. All the patients underwent all-arthroscopic fabellectomy for diagnosis and treatment. Investigations of the resected fabella suggested chronic impingement with apparent osteophyte formation and cartilage wearing of the articular side. All patients have been continually followed up at our outpatient department and reported to be pain free after the procedure. CONCLUSIONS: In the patients presenting posterolateral pain, fabella syndrome cannot be ignored due to its relative higher presence in Asian population. In our experience, the all-arthroscopic fabellectomy offers a smaller wound size, less post-operative pain, fewer days of hospitalization and quicker time to rehabilitation for the patients with chronic posterolateral knee pain caused by fabella syndrome.


Assuntos
Ossos Sesamoides , Humanos , Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Dor , Ossos Sesamoides/diagnóstico por imagem , Ossos Sesamoides/cirurgia , Síndrome
6.
Polymers (Basel) ; 13(9)2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-34068784

RESUMO

Acinetobacter baumannii (A. baumannii) is a common and challenging pathogen of nosocomial infections, due to its ability to survive on inanimate objects, desiccation tolerance, and resistance to disinfectants. In this study, we investigated an antibacterial strategy to combat A. baumannii via the combination of antibiotics and silver protein. This strategy used a functional platform consisting of silver nanoparticles (AgNPs) resurrected from silver-based calcium thiophosphate (SSCP) through casein and arginine. Then, the silver protein was combined with tigecycline, the first drug in glycylcycline antibiotic, to synergistically inhibit the viability of A. baumannii. The synergistic antibacterial activity was confirmed by the 96-well checkerboard method to determine their minimum inhibitory concentrations (MIC) and calculated for the combination index (CI). The MIC of the combination of silver protein and tigecycline (0.31 mg/mL, 0.16 µg/mL) was significantly lower than that of the individual MIC, and the CI was 0.59, which indicates a synergistic effect. Consequently, we integrated the detailed synergistic antibacterial properties when silver protein was combined with tigecycline. The result could make for a promising approach for the treatment of A. baumannii.

7.
RSC Adv ; 10(67): 41202-41208, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-35519222

RESUMO

In this research, negative-charge carbon dots (CDs) were synthesized in one-step using a microwave and found to have potential antibacterial ability against multi-drug resistant bacteria. The CDs were synthesized by using citric acid and urea as precursors, and characterized by FT-IR, TEM and fluorescence spectrophotometry. The average size of CDs was about 2.5 nm, and the ζ potential was -11.06 mV. In the following antibacterial activity test, time-killing curve experiments and colony-forming assay were carried out to determine the minimum bactericidal concentration (MBC) and minimum inhibitory concentration (MIC) of the CDs against methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-intermediate Staphylococcus aureus (VISA). The data showed the MBC of the CDs against MRSA is 2.5 mg mL-1, and the MIC of the CDs against MRSA is 0.63 mg mL-1; the MBC of the CDs against VISA is 1.25 mg mL-1, and the MIC of the CDs against VISA is 0.63 mg mL-1. The results demonstrated that the negative-charge CDs have potential against multi-drug resistant Staphylococcus aureus (S. aureus), and may serve as alternatives for therapy in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...