Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 2(10): 7313-7319, 2017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-30023546

RESUMO

There is an ever-growing need for detection methods that are both sensitive and efficient, such that reagent and sample consumption is minimized. Nanopillar arrays offer an attractive option to fill this need by virtue of their small scale in conjunction with their field enhancement intensity gains. This work investigates the use of nanopillar substrates for the detection of the uranyl ion and DNA, two analytes unalike but for their low quantum efficiencies combined with the need for high-throughput analyses. Herein, the adaptability of these platforms was explored, as methods for the successful surface immobilization of both analytes were developed and compared, resulting in a limit of detection for the uranyl ion of less than 1 ppm with a 0.2 µL sample volume. Moreover, differentiation between single-stranded and double-stranded DNA was possible, including qualitative identification between double-stranded DNA and DNA of the same sequence, but with a 10-base-pair mismatch.

2.
Anal Chem ; 88(17): 8741-8, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27510171

RESUMO

This work presents the retention capabilities and surface area enhancement of highly ordered, high-aspect-ratio, open-platform, two-dimensional (2D) pillar arrays when coated with a thin layer of porous silicon oxide (PSO). Photolithographically prepared pillar arrays were coated with 50-250 nm of PSO via plasma-enhanced chemical vapor deposition and then functionalized with either octadecyltrichlorosilane or n-butyldimethylchlorosilane. Theoretical calculations indicate that a 50 nm layer of PSO increases the surface area of a pillar nearly 120-fold. Retention capabilities were tested by observing capillary-action-driven development under various conditions, as well as by running one-dimensional separations on varying thicknesses of PSO. Increasing the thickness of PSO on an array clearly resulted in greater retention of the analyte(s) in question in both experiments. In culmination, a two-dimensional separation of fluorescently derivatized amines was performed to further demonstrate the capabilities of these fabricated platforms.

3.
J Forensic Sci ; 58(3): 609-15, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23550595

RESUMO

A reversed phase gradient ultra performance liquid chromatography tandem mass spectrometry (UPLC/MS/MS) method has been developed for the analysis of smokeless powders. A total of 20 different components were separated by UPLC and detected by MS/MS in multiple reaction monitoring (MRM) mode. These compounds included diphenylamines, centralites, nitrotoluenes, nitroglycerin, and various phthalates. Simultaneous positive and negative electrospray ionization (ESI) was used along with negative atmospheric pressure chemical ionization (APCI) to detect all compounds in a single analysis. Analysis times were under 8 min with a gradient of 10-73% organic at a flow rate of 0.500 mL/min. With this method, ultraviolet and MRM limits of detection ranging from 0.08 to 2.6 ng and 0.4-64 ng injected were achieved. Commercially available smokeless powders were also extracted with methylene chloride and characterized using the developed UPLC/MS/MS method. The procedure permits the determination of compositional differences between different brands as well as lot-to-lot variations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...