Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 50(6): 691-702, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35381914

RESUMO

Serious cervical spine injuries have been documented from falls into foam pits at trampoline parks. To address the lack of evidence on how foam pits should be designed for mitigating neck injury risk, this study aimed to quantify neck loads during head-first entry into varying foam pit designs. An instrumented Hybrid III anthropomorphic test device was dropped head-first from a height of up to 1.5 m into three differently constructed foam pits, each using a different mechanism to prevent direct contact between the falling person and the floor (foam slab, trampoline or net bed). Measured neck loads were compared to published injury reference values. In the simplest, foam-only pit design, increasing foam depth tended to reduce peak compressive force. At least one injury assessment reference metric was exceeded in all pit conditions tested for 1.5 m falls, most commonly the time-dependent neck compression criterion. The results highlight the importance of adequate foam depth in combination with appropriate pit design in minimizing injury risk. The risk of cervical spine injury may not be reduced sufficiently with current foam pit designs.


Assuntos
Lesões do Pescoço , Pescoço , Aerossóis , Fenômenos Biomecânicos , Humanos , Lesões do Pescoço/prevenção & controle
2.
Sensors (Basel) ; 21(21)2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34770643

RESUMO

This study illustrates the application of a tri-axial accelerometer and gyroscope sensor device on a trampolinist performing the walking-the-wall manoeuvre on a high-performance trampoline to determine the performer dynamic conditions. This research found that rigid vertical walls would allow the trampolinist to obtain greater control and retain spatial awareness at greater levels than what is achievable on non-rigid vertical walls. With a non-rigid padded wall, the reaction force from the wall can be considered a variable force that is not constrained, and would not always provide the feedback that the trampolinist needs to maintain the balance with each climb up the wall and fall from height. This research postulates that unattenuated vertical walls are safer than attenuated vertical walls for walking-the-wall manoeuvres within trampoline park facilities. This is because non-rigid walls would provide higher g-force reaction feedback from the wall, which would reduce the trampolinist's control and stability. This was verified by measuring g-force on a horizontal rigid surface versus a non-rigid surface, where the g-force feedback was 27% higher for the non-rigid surface. Control and stability are both critical while performing the complex walking-the-wall manoeuvre. The trampolinist experienced a very high peak g-force, with a maximum g-force of approximately 11.5 g at the bottom of the jump cycle. It was concluded that applying impact attenuation padding to vertical walls used for walking-the-wall and similar activities would increase the likelihood of injury; therefore, padding of these vertical surfaces is not recommended.


Assuntos
Acelerometria , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...