Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 117(5): 1222-1231, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37423292

RESUMO

PURPOSE: Stereotactic body radiation therapy for tumors near the central airways implies high-grade toxic effects, as concluded from the HILUS trial. However, the small sample size and relatively few events limited the statistical power of the study. We therefore pooled data from the prospective HILUS trial with retrospective data from patients in the Nordic countries treated outside the prospective study to evaluate toxicity and risk factors for high-grade toxic effects. METHODS AND MATERIALS: All patients were treated with 56 Gy in 8 fractions. Tumors within 2 cm of the trachea, the mainstem bronchi, the intermediate bronchus, or the lobar bronchi were included. The primary endpoint was toxicity, and the secondary endpoints were local control and overall survival. Clinical and dosimetric risk factors were analyzed for treatment-related fatal toxicity in univariable and multivariable Cox regression analyses. RESULTS: Of 230 patients evaluated, grade 5 toxicity developed in 30 patients (13%), of whom 20 patients had fatal bronchopulmonary bleeding. The multivariable analysis revealed tumor compression of the tracheobronchial tree and maximum dose to the mainstem or intermediate bronchus as significant risk factors for grade 5 bleeding and grade 5 toxicity. The 3-year local control and overall survival rates were 84% (95% CI, 80%-90%) and 40% (95% CI, 34%-47%), respectively. CONCLUSIONS: Tumor compression of the tracheobronchial tree and high maximum dose to the mainstem or intermediate bronchus increase the risk of fatal toxicity after stereotactic body radiation therapy in 8 fractions for central lung tumors. Similar dose constraints should be applied to the intermediate bronchus as to the mainstem bronchi.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Neoplasias Pulmonares/patologia , Brônquios/efeitos da radiação , Fatores de Risco , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos
2.
Phys Med ; 88: 53-64, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34175747

RESUMO

INTRODUCTION: Dose-response relationships for local control of lung tumours treated with stereotactic body radiotherapy (SBRT) have proved ambiguous, however, these have been based on the prescribed or planned dose. Delivered dose to the target may be a better predictor for local control. In this study, the probability of the delivered minimum dose to the clinical target volume (CTV) in relation to the prescribed dose was estimated for a cohort of patients, considering geometrical uncertainties. MATERIALS AND METHODS: Delivered doses were retrospectively simulated for 50 patients treated with SBRT for lung tumours, comparing two image-guidance techniques: pre-treatment verification computed tomography (IG1) and online cone-beam computed tomography (IG2). The prescribed dose was typically to the 67% isodose line of the treatment plan. Simulations used in-house software that shifted the static planned dose according to a breathing motion and sampled setup/matching errors. Each treatment was repeatedly simulated, generating a multiplicity of dose-volume histograms (DVH). From these, tumour-specific and population-averaged statistics were derived. RESULTS: For IG1, the probability that the minimum CTV dose (D98%) exceeded 100% of the prescribed dose was 90%. With IG2, this probability increased to 99%. CONCLUSIONS: Doses below the prescribed dose were delivered to a considerably larger part of the population prior to the introduction of online soft-tissue image-guidance. However, there is no clear evidence that this impacts local control, when compared to previous published data.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
3.
Acta Oncol ; 56(9): 1189-1196, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28388257

RESUMO

INTRODUCTION: Geometrical uncertainties can result in a delivered dose to the tumor different from that estimated in the static treatment plan. The purpose of this project was to investigate the accuracy of the dose calculated to the clinical target volume (CTV) with the dose-shift approximation, in stereotactic body radiation therapy (SBRT) of lung tumors considering setup errors and breathing motion. The dose-shift method was compared with a beam-shift method with dose recalculation. MATERIAL AND METHODS: Included were 10 patients (10 tumors) selected to represent a variety of SBRT-treated lung tumors in terms of tumor location, CTV volume, and tumor density. An in-house developed toolkit within a treatment planning system allowed the shift of either the dose matrix or a shift of the beam isocenter with dose recalculation, to simulate setup errors and breathing motion. Setup shifts of different magnitudes (up to 10 mm) and directions as well as breathing with different peak-to-peak amplitudes (up to 10:5:5 mm) were modeled. The resulting dose-volume histograms (DVHs) were recorded and dose statistics were extracted. RESULTS: Generally, both the dose-shift and beam-shift methods resulted in calculated doses lower than the static planned dose, although the minimum (D98%) dose exceeded the prescribed dose in all cases, for setup shifts up to 5 mm. The dose-shift method also generally underestimated the dose compared with the beam-shift method. For clinically realistic systematic displacements of less than 5 mm, the results demonstrated that in the minimum dose region within the CTV, the dose-shift method was accurate to 2% (root-mean-square error). Breathing motion only marginally degraded the dose distributions. CONCLUSIONS: Averaged over the patients and shift directions, the dose-shift approximation was determined to be accurate to approximately 2% (RMS) within the CTV, for clinically relevant geometrical uncertainties for SBRT of lung tumors.


Assuntos
Neoplasias Pulmonares/cirurgia , Radiocirurgia , Erros de Configuração em Radioterapia , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...