1.
J Ultrasound Med ; 27(9): 1337-44, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18716143

RESUMO

OBJECTIVE: The purpose of this study was to compare peak systolic velocities (PSVs) and the degree of stenosis obtained with a real-time 3-dimensional (ie, 4-dimensional) Doppler ultrasound scanner (Encore PV; VueSonix Sensors Inc, Wayne, PA) to conventional Doppler ultrasound imaging of the carotid arteries (common [CCA], internal [ICA], and external [ECA]). A secondary goal was to assess Encore volume flow measurements. METHODS: Seventy patients referred for clinical carotid ultrasound participated in this pilot study. Peak systolic velocities of the CCA, ECA, and ICA were obtained bilaterally. The degree of stenosis in the ICA was calculated based on the ICA PSV and ICA/CCA PSV ratio. The Encore detects all 3-dimensional blood flow velocity vectors within 10-s longitudinal volumes of the ICA, ECA, and CCA. On the Encore, a reader determined the centerline of the vessels. The PSV and volume flow were then automatically calculated. The flow measurement error was obtained by comparing the CCA flow to the ICA and ECA flow. Data were compared using linear regression, intraclass correlation coefficients (ICCs), and Bland-Altman analysis. RESULTS: Due to technical difficulties, only 59 patients (323 vessel segments) were available for analysis. There was good agreement between methods for assessing the degree of stenosis based on the ICA PSV (ICC = 0.83; P < .0001) and, to a lesser degree, on the ICA/CCA PSV ratio (ICC = 0.65; P < .0001). Peak systolic velocity measurements obtained with conventional ultrasound and the Encore correlated in all vessels (r >or= 0.32; P < .002), and Bland-Altman analysis showed reasonable variations. The Encore mean volume flow error +/- SD was -4.1% +/- 66.4% and was not biased (P = .57). CONCLUSIONS: A new semiautomated 4-dimensional Doppler device is comparable to conventional Doppler ultrasound for assessment of carotid stenosis.


Assuntos
Inteligência Artificial , Estenose das Carótidas/diagnóstico por imagem , Ecocardiografia Doppler/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Reconhecimento Automatizado de Padrão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Ultrasound Med ; 25(1): 15-21, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16371551

RESUMO

OBJECTIVE: The purpose of this study was to quantify perfusion in vivo using contrast-enhanced subharmonic imaging (SHI). METHODS: A modified LOGIQ 9 scanner (GE Healthcare, Milwaukee, WI) operating in gray scale SHI mode was used to measure SHI time-intensity curves in vivo. Four dogs received intravenous contrast bolus injections (dose, 0.1 mL/kg), and renal SHI was performed. After 3 contrast agent injections, a microvascular staining technique based on stable (nonradioactive) isotope-labeled microspheres (BioPhysics Assay Laboratory Inc, Worcester, MA) was used to quantify the degree of perfusion in 8 sections of each kidney. Low perfusion states were induced by ligating surgically exposed segmental renal arteries followed by contrast agent injections and microvascular staining. Digital clips were transferred to a personal computer, and SHI time-intensity curves were acquired in each section using Image-Pro Plus software (Media Cybernetics, Silver Spring, MD). Subharmonic fractional blood volumes were calculated, and the perfusion was estimated from the initial slope of the fractional blood volume uptake averaged over 3 injections. Subharmonic perfusion data were compared with the gold standard (ie, the microspheres) using linear regression analysis. RESULTS: In vivo gray scale SHI clearly showed flow and, thus, perfusion in the kidneys with almost complete suppression of tissue signals. In total, 270 SHI time-intensity curves were acquired, which reduced to 94 perfusion estimates after averaging. Subharmonic perfusion estimates correlated significantly with microsphere results (r = 0.57; P < .0001). The best SHI perfusion estimates occurred for high perfusion states in the anterior of the kidneys (r = 0.73; P = .0001). The corresponding root mean square error was 2.4%. CONCLUSIONS: Subharmonic perfusion estimates have been obtained in vivo. The perfusion estimates were in reasonable to good agreement with a microvascular staining technique.


Assuntos
Albuminas/farmacocinética , Meios de Contraste/farmacocinética , Fluorocarbonos/farmacocinética , Rim/diagnóstico por imagem , Albuminas/administração & dosagem , Análise de Variância , Animais , Meios de Contraste/administração & dosagem , Cães , Fluorocarbonos/administração & dosagem , Processamento de Imagem Assistida por Computador , Injeções Intravenosas , Rim/irrigação sanguínea , Modelos Lineares , Microbolhas , Ultrassonografia