Med Phys ; 41(8): 081709, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25086519

RESUMO

PURPOSE: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. METHODS: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose-volume histograms were calculated for the patient plans. RESULTS: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of -0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local voxel-based deviation of -2.41% ± 0.75% for all voxels with dose values >20% were found for 11 modulated plans in the cheese phantom. Averaged over nine patient plans, the deviations amounted to -0.14% ± 1.97% (voxels >80%) and -0.95% ± 2.27% (>20%, local deviations). For a lung case, mean voxel-based deviations of more than 4% were found, while for all other patient plans, all mean voxel-based deviations were within ± 2.4%. CONCLUSIONS: The presented method is suitable for independent dose calculation for helical tomotherapy within the known limitations of the pencil beam algorithm. It can serve as verification of the primary dose calculation and thereby reduce the need for time-consuming measurements. By using the patient anatomy and generating full 3D dose data, and combined with measurements of additional machine parameters, it can substantially contribute to overall patient safety.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Condrossarcoma/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Movimento (Física) , Imagens de Fantasmas , Neoplasias da Próstata/tratamento farmacológico , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Tomografia Computadorizada por Raios X , Água
2.
Ear Nose Throat J ; 93(6): E24-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24932825

RESUMO

Scalp angiosarcoma represents a therapeutic challenge to all disciplines. This case report demonstrates the potential usefulness of helical tomotherapy (HT) as a new radiotherapeutic treatment option. A 71-year-old woman presented with a superficial angiosarcoma of the scalp, forehead, and left pre- and postauricular areas, with several nodular ulcerating and bleeding lesions. Irradiation of the gross tumor was performed with a total dose of 70 Gy in 2-Gy fractions and of the left cervical lymph nodes with 56 Gy in 1.6-Gy fractions. Good target coverage was achieved without compromising organs at risk, notably the brain. Treatment was very fast (661 seconds per fraction) and was administered with minimal acute toxicity (National Cancer Institute Common Toxicity Criteria: grade 2 erythema and grade 2 dysphagia). During treatment, tumor nodules dissolved into hyperkeratosis. We conclude that with HT, irradiation of the scalp and cervical lymph nodes can be conducted with minimal acute toxicity and without junction problems.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Hemangiossarcoma/radioterapia , Radioterapia de Intensidade Modulada , Couro Cabeludo , Neoplasias Cutâneas/radioterapia , Idoso , Fracionamento da Dose de Radiação , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Hemangiossarcoma/secundário , Humanos , Linfonodos , Metástase Linfática , Pescoço , Radioterapia de Intensidade Modulada/efeitos adversos , Neoplasias Cutâneas/patologia
3.
Z Med Phys ; 23(4): 324-31, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23876598

RESUMO

PURPOSE: Whenever treating a patient with percutaneous radiotherapy, a certain amount of dose is inevitably delivered to healthy tissue. This is mainly due to beam's entry and exit in the region of the target volume. In regions distant from the target volume, dose is delivered by leakage from the MLC and head scatter from the accelerator head and phantom scatter from the target volume (peripheral dose). Helical tomotherapy is a form of radiation therapy with a uniquely designed machine and delivery pattern which influence the peripheral dose. The goal of this work was to investigate peripheral dose in helical tomotherapy. The experiments were used to establish a complex characterization of the peripheral dose. MATERIALS AND METHODS: A 30*30*60cm(3) slab phantom and TLD-100 (Lithium fluoride) were used for the experiments. Treatment procedures were generated with the tomotherapy planning system (TPS). Additionally, procedures were created on the Operator Station of the tomotherapy system without a calculation of the dose distribution. The peripheral dose which was produced by a typical tomotherapy treatment plan was measured. Furthermore, these procedures were used to differentiate the parts of the peripheral dose in phantom scatter dose and head scatter and leakage dose. Additionally, the relation between peripheral dose and treatment time and between peripheral dose and delivered dose was investigated. Additionally, the peripheral dose was measured in an Alderson phantom. RESULTS: Distances of 30cm or more resulted in a decrease of the peripheral dose to less than 0.1% of the target dose. The measured doses have an offset of approximately 1cGy in comparison to the calculated doses from the TPS. The separated head scatter and leakage dose was measured in the range of 1cGy for typical treatments. Furthermore, the investigations show a linear correlation between head scatter leakage dose and treatment time and between scatter dose parts and delivered dose. A peripheral dose of 0.28% of the target dose was measured in the Alderson phantom at a distance of 17.5cm from the edge of the target volume. CONCLUSIONS: The peripheral dose delivered by a tomotherapy treatment is clinically unobjectionable. The measurements confirmed a linear correlation between head scatter and leakage and treatment time and between scatter dose and delivered dose.


Assuntos
Carga Corporal (Radioterapia) , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Espalhamento de Radiação , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Z Med Phys ; 23(2): 153-61, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22921842

RESUMO

During a helical tomotherapy a binary MLC is used for fluence modulation. The 64 pneumatically driven leaves of the MLC are either completely open or closed. The fast and frequent leaf movements result in a high demand of accuracy and stability of the MLC. This article is based on the analytical investigation of the accuracy and the stability of the MLC. Different patterns of MLC movements were generated to investigate the characteristics of the MLC. One of the considered aspects contains the friction between the leaves. The influence of variations of the compressed air on the MLC was also explored. The integrated MVCT detector of the tomotherapy system deposits the treatment data in a matrix. The detector is triggered with the linear accelerator, which is pulsed by 300Hz. The data matrix is available after the treatment. An IDL (Interactive Data Language) routine was programmed in order to analyse the matrix. The points of time, at which the leaves open (POT), and the period, in which the leaves stay open (LOT), were measured and compared with the desired values. That procedure has been repeated several times a week for approximately 6 months to investigate the stability of the MLC. Relative deviations of the LOT from -0.4% to -5.4% were measured. The friction between the leaves had no significant influence on the LOT. The available compressed air, that is used to move the leaves, depends on the number of moving leaves and also on the previous movements of the MLC. Variations of the compressed air resulted in deviations of the LOT from -1.8% to -3.7%. The measured POT deviates from the programmed POT up to -18.4ms±0.7ms. This maximal deviation correlates with a shift of the gantry angle of 0.52̊ which is negligible. The MLC has shown a stable behaviour over the 6 months. A separate consideration of the leaves showed no higher standard deviation of the LOT than ±0.7ms during the investigated time. The variation between the different leaves is much higher than the deviations of LOT caused by friction and changes of compressed air. The deviations of the LOT vary between -2.6ms and -11.0ms. The developed method is feasible in order to recognize a deterioration of the MLC performance.


Assuntos
Algoritmos , Desenho Assistido por Computador , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Radiat Oncol ; 7: 191, 2012 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-23146914

RESUMO

BACKGROUND: Helical Tomotherapy (HT) has unique capacities for the radiotherapy of large and complicated target volumes. Next generation Dynamic Jaw/Dynamic Couch HT delivery promises faster treatments and reduced exposure of organs at risk due to a reduced dose penumbra. METHODS: Three challenging clinical situations were chosen for comparison between Regular HT delivery with a field width of 2.5 cm (Reg 2.5) and 5.0 cm (Reg 5.0) and DJDC delivery with a maximum field width of 5.0 cm (DJDC 5.0): Hemithoracic Irradiation, Whole Abdominal Irradiation (WAI) and Total Marrow Irradiation (TMI). For each setting, five CT data sets were chosen, and target coverage, conformity, integral dose, dose exposure of organs at risk (OAR) and treatment time were calculated. RESULTS: Both Reg 5.0 and DJDC 5.0 achieved a substantial reduction in treatment time while maintaining similar dose coverage. Treatment time could be reduced from 10:57 min to 3:42 min / 5:10 min (Reg 5.0 / DJDC 5.0) for Hemithoracic Irradiation, from 18:03 min to 8:02 min / 8:03 min for WAI and to 18:25 min / 18:03 min for TMI. In Hemithoracic Irradiation, OAR exposure was identical in all modalities. For WAI, Reg 2.5 resulted in lower exposure of liver and bone. DJDC plans showed a small but significant increase of ∼ 1 Gy to the kidneys, the parotid glans and the thyroid gland. While Reg 5.0 and DJDC were identical in terms of OAR exposure, integral dose was substantially lower with DJDC, caused by a smaller dose penumbra. CONCLUSIONS: Although not clinically available yet, next generation DJDC HT technique is efficient in improving the treatment time while maintaining comparable plan quality.


Assuntos
Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Abdome/efeitos da radiação , Medula Óssea/efeitos da radiação , Humanos , Dosagem Radioterapêutica , Tórax/efeitos da radiação , Fatores de Tempo