Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vet Intern Med ; 34(2): 783-789, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32003500

RESUMO

BACKGROUND: Quantitative bacterial culture and susceptibility testing is the gold standard diagnostic for determining bacterial urinary tract infection. Transport of samples to external reference laboratories is common practice in veterinary medicine. OBJECTIVE: To compare bacterial culture and susceptibility results from clinical urine samples when streak plate inoculation is performed immediately after sample collection versus after transport to a reference laboratory. To determine the clinical implications of discrepant culture results. ANIMALS: One hundred and ninety-four canine and 45 feline urine samples that were submitted for urinalysis and urine culture and susceptibility testing. METHODS: This was a prospective, cross-sectional study. Streak plate inoculations were performed on urine samples immediately after collection and also after transport to a reference laboratory. Samples were stored in plain sterile tubes and refrigerated up to 24 hours before transport. Culture results were compared, and discordant results were evaluated for clinical relevance. Signalment, comorbidities, lower urinary tract signs, and antimicrobial history were recorded. RESULTS: Kappa coefficient for agreement between plating methods was 0.884. Twenty-two (71%) of 31 discrepant results were determined to have no clinical impact. Though 35% of clean midstream samples had discrepant culture results, only 8% of these had clinical impact. Conversely, 8.6% from cystocentesis were discrepant, but 41% of these had clinical impact. CONCLUSIONS AND CLINICAL IMPORTANCE: Provided urine samples are stored and transported appropriately, the immediate preplating of urine for culture and susceptibility testing is unnecessary in the majority of cases. Despite more discrepancies in plating methods for midstream samples, the minority were of clinical importance.


Assuntos
Doenças do Gato/urina , Doenças do Cão/urina , Manejo de Espécimes/veterinária , Infecções Urinárias/veterinária , Urina/microbiologia , Animais , Anti-Infecciosos/uso terapêutico , Doenças do Gato/tratamento farmacológico , Doenças do Gato/microbiologia , Gatos , Estudos Transversais , Doenças do Cão/tratamento farmacológico , Doenças do Cão/microbiologia , Cães , Feminino , Masculino , Testes de Sensibilidade Microbiana/veterinária , Estudos Prospectivos , Urinálise/veterinária , Infecções Urinárias/urina
2.
J Vet Emerg Crit Care (San Antonio) ; 28(6): 551-558, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30320489

RESUMO

OBJECTIVE: To characterize disseminated intravascular coagulation (DIC), liver failure (LF), post-hepatic cholestasis (PHC), and anticoagulant rodenticide intoxication (ROD) in dogs using an immunoturbidimetric coagulation analyzer and to characterize the relationship between clinical bleeding and bleeding parameters. DESIGN: Retrospective study (August 2014-July 2015). SETTING: University teaching hospital. ANIMALS: Forty-seven client-owned dogs diagnosed with DIC (n = 24), LF (n = 9), PHC (n = 5), or ROD (n = 9) based on history, clinical pathology, cytology, histopathology. or exploratory surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Median prothrombin time (PT), activated partial thromboplastin time (aPTT), and quantitative fribrinogen assay (QFA) were above the reference interval for DIC, LF, PHC and ROD with the exception of a normal QFA for LF. Clot curve analysis for DIC was characterized by elevated PT Delta, PT first derivative, and aPTT Delta, and normal for aPTT second derivative; all LF parameters were within the RI; all PHC parameters were above the RI; and ROD had elevated aPTT delta, but low aPTT second derivative. Coagulopathic bleeding recognized within the DIC group was characterized by median PT delta in mABS (milliabsorbance), first derivative and aPTT delta values in mABS within the RI at 35.0, 55.5 and 38, respectively. The nonbleeding DIC group median values of these same parameters were 189.5, 586.5 and 288, respectively. CONCLUSIONS: The classically utilized indicators of secondary hemostasis, PT and aPTT, were prolonged within all 4 groups; DIC, LF, PHC and ROD as expected. Fibrinogen concentration was increased in both PHC and ROD, decreased in LF and increased but with a bimodal distribution in DIC that correlated with clinical bleeding. The degree of PT and aPTT prolongation did not correlate with clinical bleeding in the DIC group, however clot curve analysis, did reveal an association.


Assuntos
Transtornos da Coagulação Sanguínea/veterinária , Doenças do Cão/sangue , Rodenticidas/intoxicação , Animais , Transtornos da Coagulação Sanguínea/sangue , Transtornos da Coagulação Sanguínea/induzido quimicamente , Testes de Coagulação Sanguínea/instrumentação , Testes de Coagulação Sanguínea/veterinária , Doenças do Cão/induzido quimicamente , Cães , Feminino , Masculino , Tempo de Tromboplastina Parcial/veterinária , Intoxicação/sangue , Intoxicação/veterinária , Tempo de Protrombina/veterinária , Valores de Referência , Estudos Retrospectivos
3.
J Vet Emerg Crit Care (San Antonio) ; 28(4): 317-325, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29901847

RESUMO

OBJECTIVE: To evaluate the technical performance of the turbidimetric ACL-TOP CTS 300 coagulation analyzer (IL) in dogs and cats and to create reference intervals for standard and novel parameters. DESIGN: Coagulation testing results from dogs and cats generated by the IL were prospectively compared with another mechanical clot detection system. Precision was documented and reference intervals were created for prothrombin time, activated partial thromboplastin time, and Clauss fibrinogen and D-dimer values, as well as for the quantitative clot curve parameters (high and low amplitude, delta, and first and second derivative curves). Clot curve signatures containing common artifacts due to lipemia, hemolysis, or preactivation were demonstrated. ANIMALS: Residual frozen plasma from 20 dogs and 10 cats was used for method comparison; prospectively recruited healthy dogs (n = 48) and cats (n = 45) were used for reference interval and precision studies. MEASUREMENTS AND MAIN RESULTS: Bland-Altman analysis showed a proportional positive bias in the IL compared with mechanical clot detection in dogs and a suggestion of a similar pattern in cats. Precision was good and met manufacturer's recommendations for all assays. Reference intervals are reported. Clot curve artifacts were similar in animals to those reported in people. CONCLUSIONS: The turbidimetric system had a slight high proportional positive bias compared with mechanical clot detection. Thus, new reference intervals were generated including for novel parameters generated by clot curve analysis. Some preanalytical errors can be identified by inspection of clot curves. This robust novel technology compares favorably with mechanical endpoint detection methods and can be used in dogs and cats.


Assuntos
Testes de Coagulação Sanguínea/veterinária , Gatos/sangue , Cães/sangue , Animais , Testes de Coagulação Sanguínea/instrumentação , Desenho de Equipamento , Feminino , Masculino , Tempo de Tromboplastina Parcial/veterinária , Estudos Prospectivos , Tempo de Protrombina/veterinária , Valores de Referência
4.
Acad Emerg Med ; 21(8): 912-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25154469

RESUMO

OBJECTIVES: Asynchronous e-learning allows for targeted teaching, particularly advantageous when bedside and didactic education is insufficient. An asynchronous e-learning curriculum has not been studied across multiple centers in the context of a clinical rotation. We hypothesize that an asynchronous e-learning curriculum during the pediatric emergency medicine (EM) rotation improves medical knowledge among residents and students across multiple participating centers. METHODS: Trainees on pediatric EM rotations at four large pediatric centers from 2012 to 2013 were randomized in a Solomon four-group design. The experimental arms received an asynchronous e-learning curriculum consisting of nine Web-based, interactive, peer-reviewed Flash/HTML5 modules. Postrotation testing and in-training examination (ITE) scores quantified improvements in knowledge. A 2 × 2 analysis of covariance (ANCOVA) tested interaction and main effects, and Pearson's correlation tested associations between module usage, scores, and ITE scores. RESULTS: A total of 256 of 458 participants completed all study elements; 104 had access to asynchronous e-learning modules, and 152 were controls who used the current education standards. No pretest sensitization was found (p = 0.75). Use of asynchronous e-learning modules was associated with an improvement in posttest scores (p < 0.001), from a mean score of 18.45 (95% confidence interval [CI] = 17.92 to 18.98) to 21.30 (95% CI = 20.69 to 21.91), a large effect (partial η(2) = 0.19). Posttest scores correlated with ITE scores (r(2) = 0.14, p < 0.001) among pediatric residents. CONCLUSIONS: Asynchronous e-learning is an effective educational tool to improve knowledge in a clinical rotation. Web-based asynchronous e-learning is a promising modality to standardize education among multiple institutions with common curricula, particularly in clinical rotations where scheduling difficulties, seasonality, and variable experiences limit in-hospital learning.


Assuntos
Instrução por Computador/métodos , Currículo , Medicina de Emergência/educação , Internet , Internato e Residência/métodos , Pediatria/educação , Competência Clínica , Humanos , Estudos Prospectivos , Estados Unidos
5.
Monash Bioeth Rev ; 21(1): S79-91, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15828158

RESUMO

There is nothing like an overwhelming consensus of opinion to encourage a less than rigourous approach to analyzing complex ethical issues. Unfortunately, this is nowhere more apparent than in the discussion of human reproductive cloning contained in the federal House of Representatives Standing Committee on Legal and Constitutional Affairs' report on human cloning, released last August. The report may well fulfil the first half of its project, namely the empirical task of adequately summarizing and categorizing the various submissions made to the Committee. However, it is clearly inadequate as a discussion of the ethical and legal permissibility of human reproductive cloning.


Assuntos
Clonagem de Organismos/ética , Clonagem de Organismos/legislação & jurisprudência , Formulação de Políticas , Direitos Sexuais e Reprodutivos , Comitês Consultivos , Austrália , Democracia , Pesquisas com Embriões/ética , Pesquisas com Embriões/legislação & jurisprudência , Regulamentação Governamental , Humanos , Política Pública , Direitos Sexuais e Reprodutivos/ética , Técnicas de Reprodução Assistida/ética , Técnicas de Reprodução Assistida/legislação & jurisprudência , Células-Tronco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...