Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 13(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892078

RESUMO

This in vitro study aimed to investigate the diagnostic potential of short-wave infrared transillumination (SWIRT) at 1050, 1200 and 1300 nm for the detection of proximal caries in molars and premolars. It was compared to the diagnostic performance of bitewing radiography (BWR) and micro-computed tomography (µCT) as the reference standard. 250 sound or decayed proximal surfaces of permanent posterior extracted teeth were examined using (1) SWIRT at 1050, 1200 and 1300 nm with two camera systems of different resolutions, (2) BWR and (3) µCT. Thresholds were defined for both test methods and the reference standard for caries in general, enamel caries and dentin caries. All images were assessed by two examiners twice, at an interval of two weeks. SWIRT at wavelengths of 1050, 1200 and 1300 nm achieved sensitivity values more than 2.5 times higher than BWR (enamel caries 3.2-4.4 times; dentin caries 3.25-4.25 times) for the detection of proximal caries. Sensitivity values of SWIRT improved with the higher wavelength. No significant difference was found in diagnostic quality between the two camera systems. SWIRT at 1300 nm imaged proximal enamel caries with the highest accuracy, while the physical optimum for transillumination in dentin was located at a lower wavelength (<1000 nm).

2.
Clin Oral Investig ; 26(9): 5847-5855, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35588022

RESUMO

OBJECTIVES: This in vitro study aimed to investigate the optical attenuation of light at 405, 660 and 780 nm sent through sound and carious human enamel and dentin, including respective individual caries zones, as well as microscopically sound-appearing tissue close to a carious lesion. MATERIALS AND METHODS: Collimated light transmission through sections of 1000-125-µm thickness was measured and used to calculate the attenuation coefficient (AC). The data were statistically analysed with a MANOVA and Tukey's HSD. Precise definition of measurement points enabled separate analysis within the microstructure of lesions: the outer and inner halves of enamel (D1, D2), the translucent zone (TZ) within dentin lesions and its adjacent layers, the enamel side of the translucent zone (ESTZ) and the pulpal side of the translucent zone (PSTZ). RESULTS: The TZ could be distinguished from its adjacent layers and from caries-free dentin at 125 µm. Sound-appearing dentin close to caries lesions significantly differed from caries-free dentin at 125 µm. While sound and carious enamel exhibited a significant difference (p < 0.05), this result was not found for D1 and D2 enamel lesions (p > 0.05). At 405 nm, no difference was found between sound and carious dentin (p > 0.05). CONCLUSIONS: Light optical means enable the distinction between sound and carious tissue and to identify the microstructure of dentin caries partially as well as the presence of tertiary dentin formation. Information on sample thickness is indispensable when interpreting the AC. CLINICAL RELEVANCE: Non-ionising light sources may be suitable to detect lesion progression and tertiary dentin.


Assuntos
Cárie Dentária , Dentina , Cárie Dentária/patologia , Esmalte Dentário/patologia , Dentina/química , Humanos
3.
Clin Oral Investig ; 26(1): 543-553, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34636940

RESUMO

OBJECTIVES: This in vitro study analysed potential of early proximal caries detection using 3D range data of teeth consisting of near-infrared reflection images at 850 nm (NIRR). MATERIALS AND METHODS: Two hundred fifty healthy and carious permanent human teeth were arranged pairwise, examined with bitewing radiography (BWR) and NIRR and validated with micro-computed tomography. NIRR findings were evaluated from buccal, lingual and occlusal (trilateral) views according to yes/no decisions about presence of caries. Reliability assessments included kappa statistics and revealed high agreement for both methods. Statistical analysis included cross tabulation and calculation of sensitivity, specificity and AUC. RESULTS: Underestimation of caries was 24.8% for NIRR and 26.4% for BWR. Overestimation was 10.4% for occlusal NIRR and 0% for BWR. Trilateral NIRR had overall accuracy of 64.8%, overestimation of 15.6% and underestimation of 19.6%. NIRR and BWR showed high specificity and low sensitivity for proximal caries detection. CONCLUSIONS: NIRR achieved diagnostic results comparable to BWR. Trilateral NIRR assessments overestimated presence of proximal caries, revealing stronger sensitivity for initial caries detection than BWR. CLINICAL RELEVANCE: NIRR provided valid complement to BWR as diagnostic instrument. Investigation from multiple angles did not substantially improve proximal caries detection with NIRR.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Cárie Dentária/diagnóstico por imagem , Humanos , Radiografia Interproximal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tecnologia , Microtomografia por Raio-X
4.
Dent Mater ; 38(1): 79-93, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34836696

RESUMO

OBJECTIVES: Upon initial proximal wall construction, the favorable C-factor of class-II cavities may become unfavorable. This study investigated the application method on bulk-fill resin composite polymerization shrinkage. METHODS: Occluso-proximal class-II cavities were prepared in 40 molars and bonded with a self-etch adhesive (Adhese Universal). The study groups varied according to the resin composite application: group-1: bulk application, Tetric EvoCeram Bulk Fill (TBF); group-2: proximal wall construction (TBF) and occlusal cavity filling (TBF); group-3: thin flowable liner layer, Tetric EvoFlow Bulk Fill (TEF) and bulk filling (TBF); group-4: flowable liner (TEF), proximal wall (TBF), occlusal cavity (TBF); and group-5: bulk application, SDR (3 mm) and capping layer (TBF, 1 mm). Each resin composite increment was scanned twice using micro-CT (uncured, cured 40 s) at a resolution of 16 µm. Shrinkage vectors and volumetric polymerization shrinkage were evaluated and statistically analyzed (one-way ANOVA). SEM images were used to investigate the tooth-restoration interface. RESULTS: Shrinkage vectors differed significantly among the groups and were greatest in gp5-fl/SDR (47.6 µm), followed by gp1-TBF (23.8 µm) and least in gp5-fl/SDR+TBF (11.1 µm). Volumetric shrinkage varied significantly with the use of SDR (gp5-fl/SDR: 2.6%) and TEF (gp4-fl/TEF: 2.5%) to TBF (gp4-fl/TEF+wl/TBF: 0.6%) in the incremental application. SIGNIFICANCE: Building a proximal resin composite wall yielded smaller shrinkage vectors than the bulk application. Applying a thin flowable liner decreased the shrinkage vectors, even more when building a proximal wall. A thin flowable liner is recommended when building a proximal resin composite wall.


Assuntos
Resinas Compostas , Cárie Dentária , Restauração Dentária Permanente/métodos , Humanos , Teste de Materiais , Polimerização , Microtomografia por Raio-X
5.
Dentomaxillofac Radiol ; 50(6): 20210005, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33956491

RESUMO

OBJECTIVES: The aim of this in vitro study was to evaluate the diagnostic potential of near-infrared reflection at 780 nm (NIRR780nm) for early proximal caries detection on the occlusal, buccal and oral surfaces of molars and premolars under simulated, clinically relevant conditions. The findings were validated by micro-computed tomography (µCT). METHODS: Bitewing radiography (BWR) was used as a comparative diagnostic method. 250 sound or decayed permanent teeth were examined using NIRR780nm and BWR. The NIRR780nm findings were evaluated using yes/no decisions depending on the presence of caries lesions, as the enamel-dentin junction was not detectable in the majority of samples. All NIRR780nm, BWR and µCT findings were obtained twice by two trained examiners. NIRR780nm images were evaluated both occlusally alone and combined occlusally, lingually and buccally. All findings were presented in a cross-table. Sensitivity, specificity and area under the curve (AUC) values were calculated. Reliability assessment was performed using κ statistics. RESULTS: Underestimation of caries was observed for NIRR780nm in 26.0% of all surfaces and for BWR in 32.8% of all surfaces. Overestimation was 10.0% for NIRR780nm and 0.4% for BWR. Trilateral NIRR780nm assessment exhibited an overall accuracy of 67.2 %, an underestimation of 13.6% and an overestimation of 19.2%. Trilateral NIRR780nm exhibited 63.0% sensitivity and 69.6% specificity, while BWR exhibited 26.7% sensitivity but 100% specificity for proximal caries detection. CONCLUSION: NIRR780nm is not suitable for reliable detection of early proximal caries, even with the application of an ideal setup and optimized in vitro conditions.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Cárie Dentária/diagnóstico por imagem , Humanos , Radiografia Interproximal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transiluminação , Microtomografia por Raio-X
6.
BMC Oral Health ; 21(1): 97, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33663454

RESUMO

BACKGROUND: The purpose of this prospective clinical diagnostic study with validation was to compare the diagnostic accuracy of near-infrared transillumination (NIRT), laser fluorescence measurement (LF), alternating current impedance spectroscopy (ACIS) and their combinations as adjunct methods to visual examination (VE) for occlusal caries detection using a hybrid reference standard. METHODS: Ninety-six first and second non-cavitated permanent molars from 76 individuals (mean age 24.2) were investigated using (VE) (ICDAS) and bitewing radiography (BWR), as well as NIRT, LF and ACIS. The findings of BWR and NIRT were evaluated by two examiners while the other examinations were conducted by one calibrated dentist. The hybrid reference standard consisted of non-operative validation based on the results of VE and BWR and operative validation. Statistical analysis included cross-tabulations, calculation of sensitivity, specificity and area under the receiver operating characteristic curve at three diagnostic thresholds: caries in general, enamel caries and dentin caries. RESULTS: NIRT, LF and ACIS exhibited high sensitivity for caries in general [1.00 (1.00-1.00), 0.77 (0.65-0.88), 0.75 (0.63-0.87)) and for dentin caries (0.97 (0.91-1.03), 0.76 (0.76-0.90), 0.64 (0.47-0.80)]. Sensitivity values for enamel caries were weak (0.21, 0.11, 0.37). Specificity values did not fall below 0.65 (NIRT) for all categories and methods, except for NIRT at the caries detection threshold (0.27). A combination of LF and ACIS with VE improved the diagnostic performance at the overall and the enamel caries threshold. The other methods showed fair to excellent discrimination at the overall caries threshold (NIRT 0.64, LF 0.89 and ACIS 0.86) and acceptable discrimination at the dentin caries threshold (NIRT 0.82, LF 0.81 and ACIS 0.79). AUROC for enamel caries exhibited the weakest discrimination. Accuracy was 65.6% for VE, 69.8% for BWR, 50.0% for NIRT, 53.1% for LF and 74.0% for ACIS. Reliability assessment for BWR and NIRT showed at least substantial agreements for all analyses. CONCLUSIONS: The methods, NIRT, LF and ACIS, revealed different potential but no impeccable performance for occlusal caries detection. All are suitable instruments to detect hidden carious lesion in dentin. As auxiliaries to VE, LF and ACIS showed an increase in diagnostic performance.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Adulto , Cárie Dentária/diagnóstico por imagem , Dentina , Fluorescência , Humanos , Estudos Prospectivos , Radiografia Interproximal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
Dentomaxillofac Radiol ; 50(3): 20200338, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32822231

RESUMO

OBJECTIVES: We aimed to compare the diagnostic accuracy of two intraoral digital X-ray sensors-the charged-coupled device (CCD) and complementary metal-oxide-semiconductor (CMOS)-for proximal caries detection in permanent molar and premolar teeth. Micro-CT served as the reference standard. METHODS: 250 samples were mounted in three-dimensional (3D)-printed phantoms, and their proximal surfaces were evaluated by ICDAS criteria directly to create a balanced sample. Bitewing radiography was conducted using 3D-constructed X-ray phantoms with a CCD sensor at a 0.08 s and a CMOS sensor at 0.12 and 0.16 s exposure time. Two examiners determined the diagnostic decisions twice at appropriate intervals. Three diagnostic thresholds for sound surfaces and enamel and dentin caries were defined and presented in a cross-table. Sensitivity and specificity values and overall accuracy were calculated, and receiver operating curves were generated and compared. Reliability assessment was performed using linear weighted κ statistics. RESULTS: The overall accuracies between the reference standard and different sensors and exposure times were 63.1% (CCD), 67.1% (CMOS sensor at 0.12 s) and 70.7% (CMOS sensor at 0.08 s). High specificity but low sensitivity values were found for all examination conditions at all thresholds. The area under the curve comparison values revealed no significant difference between sensor types and exposure times. Linear-weighted κ analysis revealed almost perfect agreement for all assessments. CONCLUSION: No significant difference was found for diagnostic performance of proximal caries detection between the different sensors and exposure times. The increased exposure time did not lead to a significant diagnostic benefit.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Cárie Dentária/diagnóstico por imagem , Humanos , Curva ROC , Radiografia Dentária Digital , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Microtomografia por Raio-X , Raios X
8.
Clin Oral Investig ; 25(3): 1281-1289, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32613436

RESUMO

INTRODUCTION: The aim of this study was to experimentally investigate the potential of different light wavelengths to distinguish between healthy and carious tissue using a two-circle goniometer. MATERIALS AND METHODS: Tooth slices were prepared from extracted human teeth that were caries free (n = 15) or had occlusal caries lesions (n = 10). The tooth slices were irradiated with diode laser modules of different wavelengths (532, 650, 780 nm). The transmitted and scattered laser light was spatially measured with a detector rotating on a two-circle goniometer. The anisotropy factor and attenuation coefficients were calculated. RESULTS: Enamel was more transparent than dentin and showed wavelength-dependent attenuation. Healthy dentin showed strong light scattering at all wavelengths, independent of the tested wavelength. The calculated attenuation coefficients of carious and healthy tooth tissue differed significantly (p < 0.05; t test). In contrast to healthy enamel, carious enamel showed lower light transmission and an increase in scattering. Differences in the light attenuation of carious versus healthy dentin were less pronounced than those for enamel. Carious dentin was slightly more transparent than healthy dentin. The light of longer wavelengths showed a better penetration of all tooth structures compared with shorter wavelengths. CONCLUSION: Healthy and carious dentin and enamel exhibited distinct optical properties using laser light at different wavelengths. In dentin, changes in the optical properties caused by caries are significantly less pronounced. CLINICAL RELEVANCE: The clear distinction between healthy and carious enamel makes optical caries diagnostic systems ideal tools for early caries detection.


Assuntos
Cárie Dentária , Dente , Cárie Dentária/diagnóstico , Suscetibilidade à Cárie Dentária , Esmalte Dentário , Dentina , Humanos
9.
Lasers Med Sci ; 35(9): 2049-2058, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32594346

RESUMO

The aim of this study was to assess near-infrared transillumination with high dynamic range imaging (NIRT-HDRI) for occlusal caries detection in vitro and to compare it with visual inspection using the International Caries Detection and Assessment System II (ICDAS) and digital bitewing radiography (BWR). Sixty-one extracted permanent molars with sound or occlusal carious surfaces without severe cavitation were visually assembled. Two examiners assessed twice these surfaces independently using ICDAS, BWR and NIRT-HDRI. The latter was performed with a prototype consisting of two laser sources (780 nm), a CCD sensor and subsequent processing with image analysis software. Thresholds for carious surfaces, enamel and dentin lesions were defined for all methods. Micro-computed tomography served as the reference standard. Linear weighted Kappa analysis of the methods versus the reference at the threshold carious surface, enamel and dentin lesion revealed 0.59/0.08/0.12 for ICDAS, 0.37/- 0.06/0.58 for BWR and 0.33/- 0.01/0.51 for NIRT-HDRI. Sensitivity values at the three thresholds were 0.85/0.78/0.13 for ICDAS, 0.59/0.00/0.69 for BWR and 0.98/0.33/0.78 for NIRT. Specificity values at the three thresholds were 0.70/0.40/1.00 for ICDAS, 0.9./0.96/0.90 for BWR and 0.30/0.65/0.72 for NIRT-HDRI. Reliability analysis revealed substantial agreement for BWR and NIRT and almost perfect agreement for ICDAS. NIRT exhibited a strong ability to identify occlusal dental decay in general; however, it revealed a tendency towards overestimation. Its strength was the detection of dentin caries lesions compared with ICDAS and BWR. NIRT-HDRI seems to be a suitable method to detect hidden dentin caries as a supplement to visual examination.


Assuntos
Cárie Dentária/diagnóstico por imagem , Cárie Dentária/diagnóstico , Imageamento Tridimensional , Raios Infravermelhos , Transiluminação , Cárie Dentária/patologia , Esmalte Dentário/diagnóstico por imagem , Dentina/diagnóstico por imagem , Humanos , Curva ROC , Reprodutibilidade dos Testes , Microtomografia por Raio-X
10.
J Dent ; 103S: 100025, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34059307

RESUMO

OBJECTIVES: The aim of this in vivo prospective clinical study was to validate a near-infrared light transillumination (NILT) device for the detection of proximal caries lesions and compare it to the established diagnostic method of bitewing radiography (BWR). MATERIALS AND METHODS: A total of 116 interproximal posterior teeth/surfaces without gross cavitation were included and assessed with BWR and NILT. After clinical examination, the teeth with sound surfaces or non-cavitated caries lesions were separated with the use of an orthodontic separation rubber for 24h. Upon removal of the separator a silicon impression was obtained and the teeth surfaces were directly investigated. Intra- and inter-examiner reproducibility, sensitivities (SE) and specificities (SP) as well as the area under ROC curves (AUC) were calculated. RESULTS: The SE of NILT was 0.92 in D1 lesions and 1.00 in D2 and D3 lesions, respectively. BWR showed SE values of 0.81 in D1 lesions, 0.74 in D2 and 1.00 in D3 lesions, respectively. However, NILT showed lower values of SP (D1 0.38, D2 0.42 and D3 0.99) compared to BWR (D1 0.65, D2 0.88, D3 1.00). Intra-examiner reproducibility increased for both examiners from the initial examination (0.68 and 0.62) to the recall appointment (0.89 and 0.76) respectively. CONCLUSION: The performance of NILT in detection of enamel caries was comparable to BWR. NILT could be considered as a useful and reliable tool in clinical practice. However, monitoring of enamel lesions might not be accurate, since a low specificity of NILT at D1,2 level and a tendency to false positive ratings have been shown. Therefore, it is recommended that treatment decisions should not be based on NILT alone. CLINICAL RELEVANCE: This study might indicate that NILT can be used for routine patient screening but the use of BWR is still important for treatment decisions.


Assuntos
Cárie Dentária , Transiluminação , Cárie Dentária/diagnóstico por imagem , Suscetibilidade à Cárie Dentária , Humanos , Estudos Prospectivos , Radiografia Interproximal , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Eur J Oral Sci ; 127(6): 515-522, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31774207

RESUMO

The aim of this study was the in-vitro validation of VistaCam iX HD, which uses near-infrared reflection (NIRR), for proximal caries detection. It was compared with digital bitewing radiography (BWR), and micro-computed tomography (µCT) was used as the reference standard. One-hundred teeth with either sound (n = 54) or carious (n = 46) proximal surfaces were selected using visual-tactile criteria. Images of these surfaces were generated using BWR and NIRR. Evaluation was performed by two examiners, twice, at an interval of 2 weeks. All samples were scanned with a micro-computed tomograph. Thresholds were defined for sound surfaces, and for enamel and dentin lesions, for all methods. Both BWR and NIRR showed moderate sensitivity for the detection of any caries (0.50 for NIRR and 0.53 for BWR). For enamel lesions, sensitivity was lower (0.13 for NIRR and 0.31 for BWR). Specificity was high (≥0.94) in all categories for both methods. Inter-rater reliability ranged from 0.89 to 0.93 and intra-rater reliability from 0.80 to 0.89. Surface evaluation of images generated using NIRR was complicated by overexposed areas; approximately 25% of the images were not clearly interpretable. In conclusion, NIRR and BWR were found to be reproducible methods with comparable diagnostic accuracy. However, NIRR cannot be recommended as a complementary diagnostic method for assessing proximal caries in permanent molars because of problems with image quality and artefacts.


Assuntos
Cárie Dentária/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Radiografia Interproximal , Radiografia Dentária Digital , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Microtomografia por Raio-X
12.
Dent Mater ; 35(10): 1370-1377, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31351578

RESUMO

OBJECTIVE: The fracture resistance of different ultrathin occlusal computer-aided design/computer-aided manufacturing (CAD/CAM) veneers was investigated under cyclic mechanical loading to restore combined enamel-dentin defects. METHODS: Eighty-four molars were reduced occlusally until extensive dentin exposure occurred with a remaining enamel ring. Twenty-four molars were ground flat for examination of highly standardized specimens, of which 8 were treated with uniformly flat 0.3mm IPS Empress CAD and 0.3 and 0.5mm IPS e.max CAD restorations. Sixty-four molars were anatomically prepared until dentin exposure and were restored using occlusal veneers with fissure/cusp thicknesses of 0.3/0.5mm from 3 different dental CAD/CAM materials: IPS Empress CAD, IPS e.max CAD and Lava Ultimate CAD/CAM. Teeth were etched with 37% phosphoric acid, and occlusal veneers were bonded using an adhesive luting system (Syntac Primer, Adhesive, Heliobond and Variolink II). Specimens were placed under cyclic mechanical loading in a chewing simulator (1 million cycles at 50N) and were examined for cracks after each cyclic loading sequence. The anatomical 0.3/0.5mm IPS e.max CAD specimens experienced an additional 1 million cycles at 100N. Kaplan-Meier survival curves and log-rank tests were used for data analysis. RESULTS: All highly standardized and 0.3/0.5mm IPS e.max CAD specimens tolerated cyclic loading. One anatomical Lava Ultimate CAD/CAM and 10 IPS Empress CAD specimens showed cracks. SIGNIFICANCE: Ultrathin occlusal veneers of lithium disilicate ceramic and nanoceramic composite showed remarkably high fracture strength under cyclic mechanical loading. These veneers might be a tooth substance preserving option for restoring combined dentin-enamel defects.


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Cerâmica , Resinas Compostas , Desenho Assistido por Computador , Análise do Estresse Dentário , Facetas Dentárias , Teste de Materiais
13.
Clin Oral Investig ; 23(11): 3933-3940, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30693402

RESUMO

OBJECTIVES: The aim of the present in vitro study was to determine the ability of Diagnocam to detect caries at an early stage and to compare it with digital radiography. MATERIALS AND METHODS: One hundred twenty proximal surfaces composed equally of sound and decayed surfaces were evaluated by assessing images captured with Diagnocam (Kavo, Biberach, Germany) and digital radiography (DR). All images were assessed twice by two calibrated dentists with a minimum interval of 2 weeks between examinations. The results were compared with µCT scans. RESULTS: Inter-rater reliability showed nearly perfect agreement; a high intra-rater reliability was calculated. Spearman's rank correlation coefficients showed a strong correlation of Diagnocam and µCT (0.82). DR and µCT achieved a slightly lower correlation (0.73). The surfaces were categorized into sound surfaces, enamel lesions, and dentin lesions to determine intraclass correlation coefficients (ICCs), sensitivity and specificity. ICCs between µCT and DR ranged from 0.20 to 0.63. ICCs between Diagnocam and DR were higher in all categories and ranged from 0.56 to 0.83. Sensitivity, specificity, and accuracy of Diagnocam achieved mostly higher values than DR. In detecting enamel lesions, sensitivity was 0.36 for DR and 0.59 for the DC. The areas under the receiver operating characteristic (ROC) curves of Diagnocam were larger than those of DR in all categories. CONCLUSIONS: Diagnocam is more capable of detecting initial proximal lesions than DR and also has a higher sensitivity for dentin lesions. However, caries progression in dentin cannot be reliably determined with Diagnocam. CLINICAL RELEVANCE: Diagnocam may be suitable as a supplement to X-ray diagnostics in clinical use.


Assuntos
Cárie Dentária , Transiluminação , Cárie Dentária/diagnóstico , Alemanha , Humanos , Curva ROC , Radiografia Dentária Digital , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Clin Oral Investig ; 22(7): 2431-2438, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29915930

RESUMO

AIM: This study compared the diagnostic outcomes of visual inspection (VI), digital bitewing radiography (BWR), and near-infrared light transillumination (NIR-LT, DIAGNOcam, KaVo, Biberach, Germany) for occlusal caries detection and assessment of posterior teeth. PARTICIPANTS AND METHODS: This study included 203 patients (mean age 23.0 years). All individuals received a meticulous VI. Additionally, BWR and NIR-LT images were collected. All BWR and NIR-LT images were blindly evaluated for the presence of enamel caries lesions (ECLs) and dentin caries lesions (DCLs). The descriptive statistical analyses included calculation of frequencies, cross tabulations, and pairwise comparisons using Pearson chi-square tests. RESULTS: The majority of ECLs/DCLs were detected by VI in this low-risk adult population. The additional diagnostic outcomes in terms of ECLs/DCLs amounted to 5.0% (BWR) and 6.8% (NIR-LT). The combined usage of VI/NIR-LT or VI/BWR identified 95.7 and 94.4% of all ECLs/DCLs on occlusal surfaces, respectively. CONCLUSION: This comparative diagnostic study showed that VI detected the majority of occlusal caries lesions. Both additional methods showed limited benefits. Due to the valuable features of NIR-LT, i.e., X-ray freeness and clinical practicability, this method might be preferred over X-ray-based methods. Nevertheless, BWRs should be prescribed in clinical situations where insufficient fillings or multiple (deep) caries lesions are diagnosed or where there is a need to assess the caries extension in relation to the pulp. CLINICAL RELEVANCE: VI has to be understood as caries detection method of choice on occlusal surfaces in low-risk adult population which may help to avoid multiple diagnostic testing, overdiagnosis, and overtreatment.


Assuntos
Cárie Dentária/diagnóstico , Feminino , Alemanha , Humanos , Masculino , Exame Físico , Estudos Prospectivos , Radiografia Interproximal , Transiluminação/métodos , Adulto Jovem
15.
Dentomaxillofac Radiol ; 47(3): 20170292, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29227160

RESUMO

OBJECTIVES: The purpose of this in vitro study was to evaluate the inter- and intraexaminer reliability of digital bitewing (DBW) radiography and near-infrared light transillumination (NIRT) for proximal caries detection and assessment in posterior teeth. METHODS: From a pool of 85 patients, 100 corresponding pairs of DBW and NIRT images (~1/3 healthy, ~1/3 with enamel caries and ~1/3 with dentin caries) were chosen. 12 dentists with different professional status and clinical experience repeated the evaluation in two blinded cycles. Two experienced dentists provided a reference diagnosis after analysing all images independently. Statistical analysis included the calculation of simple (κ) and weighted Kappa (wκ) values as a measure of reliability. Logistic regression with a backward elimination model was used to investigate the influence of the diagnostic method, evaluation cycle, type of tooth, and clinical experience on reliability. RESULTS: Altogether, inter- and intraexaminer reliability exhibited good to excellent κ and wκ values for DBW radiography (Inter: κ = 0.60/ 0.63; wκ = 0.74/0.76; Intra: κ = 0.64; wκ = 0.77) and NIRT (Inter: κ = 0.74/0.64; wκ = 0.86/0.82; Intra: κ = 0.68; wκ = 0.84). The backward elimination model revealed NIRT to be significantly more reliable than DBW radiography. CONCLUSIONS: This study revealed a good to excellent inter- and intraexaminer reliability for proximal caries detection using DBW and NIRT images. The logistic regression analysis revealed significantly better reliability for NIRT. Additionally, the first evaluation cycle was more reliable according to the reference diagnoses.


Assuntos
Cárie Dentária/diagnóstico por imagem , Variações Dependentes do Observador , Radiografia Interproximal , Transiluminação , Humanos , Técnicas In Vitro , Raios Infravermelhos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...