Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anaesthesia ; 75(8): 1022-1027, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32348561

RESUMO

The COVID-19 pandemic has increased the demand for disposable N95 respirators. Re-usable elastomeric respirators may provide a suitable alternative. Proprietary elastomeric respirator filters may become depleted as demand increases. An alternative may be the virus/bacterial filters used in anaesthesia circuits, if they can be adequately fitted onto the elastomeric respirators. In addition, many re-usable elastomeric respirators do not filter exhaled breaths. If used for sterile procedures, this would also require modification. We designed a 3D-printed adaptor that permits elastomeric respirators to interface with anaesthesia circuit filters and created a simple modification to divert exhaled breaths through the filter. We conducted a feasibility study evaluating the performance of our modified elastomeric respirators. A convenience sample of eight volunteers was recruited. Quantitative fit testing, respiratory rate and end-tidal carbon dioxide were recorded during fit testing exercises and after 1 h of wear. All eight volunteers obtained excellent quantitative fit testing throughout the trial. The mean (SD) end-tidal carbon dioxide was 4.5 (0.5) kPa and 4.6 (0.4) kPa at baseline and after 1 h of wear (p = 0.148). The mean (SD) respiratory rate was 17 (4) breaths.min-1 and 17 (3) breaths.min-1 at baseline and after 1 h of wear (p = 0.435). Four out of eight subjects self-reported discomfort; two reported facial pressure, one reported exhalation resistance and one reported transient dizziness on exertion. Re-usable elastomeric respirators to utilise anaesthesia circuit filters through a 3D-printed adaptor may be a potential alternative to disposable N95 respirators during the COVID-19 pandemic.


Assuntos
Betacoronavirus , Infecções por Coronavirus/terapia , Filtração/instrumentação , Pneumonia Viral/terapia , Ventiladores Mecânicos , Adulto , COVID-19 , Dióxido de Carbono/fisiologia , Infecções por Coronavirus/epidemiologia , Elastômeros , Desenho de Equipamento , Reutilização de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/epidemiologia , Impressão Tridimensional , Taxa Respiratória , SARS-CoV-2 , Ventiladores Mecânicos/provisão & distribuição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...