Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Acta Pharmacol Sin ; 45(4): 831-843, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38052867

RESUMO

Chronic rhinosinusitis with nasal polyp (CRSwNP) is a refractory inflammatory disease with epithelial-mesenchymal transition (EMT) as one of the key features. Since ubiquitin modification has been shown to regulate the EMT process in other diseases, targeting ubiquitin ligases may be a potential strategy for the treatment of CRSwNP. In this study we investigated whether certain E3 ubiquitin ligases could regulate the EMT process in CRSwNP, and whether these regulations could be the potential drug targets as well as the underlying mechanisms. After screening the potential drug target by bioinformatic analyses, the expression levels of three potential E3 ubiquitin ligases were compared among the control, eosinophilic nasal polyp (ENP) and non-eosinophilic nasal polyp (NENP) group in clinical samples, and the significant decrement of the expression level of NEDD4L was found. Then, IP-MS, bioinformatics and immunohistochemistry studies suggested that low NEDD4L expression may be associated with the EMT process. In human nasal epithelial cells (hNECs) and human nasal epithelial cell line RPMI 2650, knockdown of NEDD4L promoted EMT, while upregulating NEDD4L reversed this effect, suggesting that NEDD4L inhibited EMT in nasal epithelial cells. IP-MS and Co-IP studies revealed that NEDD4L mediated the degradation of DDR1. We demonstrated that NEDD4L inhibited the ß-catenin/HIF-1α positive feedback loop either directly (degrading ß-catenin and HIF-1α) or indirectly (mediating DDR1 degradation). These results were confirmed in a murine NP model in vivo. This study for the first time reveals the regulatory role of ubiquitin in the EMT process of nasal epithelial cells, and identifies a novel drug target NEDD4L, which has promising efficacy against both ENP and NENP by suppressing ß-catenin/HIF-1α positive feedback loop.


Assuntos
Transição Epitelial-Mesenquimal , Terapia de Alvo Molecular , Pólipos Nasais , Ubiquitina-Proteína Ligases Nedd4 , Rinossinusite , Animais , Humanos , Camundongos , beta Catenina/metabolismo , Doença Crônica , Retroalimentação , Pólipos Nasais/tratamento farmacológico , Pólipos Nasais/enzimologia , Rinossinusite/tratamento farmacológico , Rinossinusite/enzimologia , Ubiquitinas/metabolismo , Ubiquitina-Proteína Ligases Nedd4/antagonistas & inibidores , Ubiquitina-Proteína Ligases Nedd4/metabolismo
2.
Laryngoscope ; 133(12): 3304-3312, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37255052

RESUMO

OBJECTIVES: To investigate the value of secretions Eosinophilic cationic protein (ECP) detection in the diagnosis of endotypes of Chronic rhinosinusitis (CRS) and its correlation with clinical symptoms, so as to provide guidance for the clinical application of EOS and ECP detection in secretions. METHODS: Patients' nasal secretions and polyps (or middle turbinate for control) were collected and their EOS% and ECP levels were measured. Correlation analysis was performed for EOS% and ECP levels in secretions and tissues, respectively. The correlation between secretions EOS% and ECP and clinical symptom scores (symptomatic visual analog scale (VAS) scores, Lanza-kennedy scores from nasal endoscopy and Lund-Mackay scores from sinus CT) was further analyzed. Receiver operating characteristic curves were used to assess the predictive potential of EOS% and ECP in nasal secretions. RESULTS: Eosinophilic chronic rhinosinusitis (ECRS) patients had higher concentrations of ECP in nasal secretions than healthy subjects and NECRS (non-eosinophilic CRS) (p < 0.0001;0.0001); EOS% in nasal secretions was higher in ECRS than healthy subjects (p = 0.0055), but the differences between ECRS and NECRS were not statistically significant (p = 0.0999). Correlation analysis showed that tissue EOS% was correlated with ECP concentration and EOS% in nasal secretions (R = 0.5943;0.2815). There was a correlation between EOS% in secretions with a total LM score (R = 0.3131); ECP concentration in secretions with a total LK score (R = 0.3792). To diagnose ECRS, the highest area under the curve (0.8230) was determined for ECP in secretions; the highest area under the curve (0.6635) was determined for EOS% in secretions. CONCLUSION: Measurement of ECP in nasal secretions is useful for non-invasive diagnosis of ECRS. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:3304-3312, 2023.


Assuntos
Eosinofilia , Pólipos Nasais , Rinite , Sinusite , Humanos , Rinite/diagnóstico , Rinite/metabolismo , Proteína Catiônica de Eosinófilo , Eosinofilia/diagnóstico , Pólipos Nasais/diagnóstico , Pólipos Nasais/metabolismo , Sinusite/diagnóstico , Sinusite/metabolismo , Doença Crônica , Eosinófilos
3.
Crit Rev Eukaryot Gene Expr ; 30(3): 253-264, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32749112

RESUMO

This article serves to evaluate the association of polymorphisms of mismatch repair genes (hMLH1 and hMSH2) with breast cancer (BC) susceptibility through a meta-analysis. Our methods involved extensive research in Chinese and English databases that examined the association of hMLH1 and hMSH2 polymorphisms with susceptibility to BC, strictly abiding by established inclusion and exclusion criteria. Software Stata 12.0 was used for statistical data analysis. A total of 12 studies were available for meta-analysis, published between 2014 and 2017, of which respectively 9 studies explored the association of hMLH1 (rs1799977 A > G and rs63750447 T > A) and 3 studies explored the association of hMSH2 (rs4987188 [Gly322Asp] and rs17217772 [Asn127Ser]) with patients' susceptibility to BC. The results showed that both the rs1799977 A > G polymorphism GA + GG genotype (especially in the Caucasian population) and the rs63750447 T > A polymorphism TA + AA genotype in the hMLH1 gene increased patients' susceptibility to BC. The genotype detection method was selected as a target for subgroup analysis. According to studies where MassARRAY assay was conducted, the rs1799977 A > G polymorphism was correlated with BC susceptibility in the dominant model, while rs4987188 (Gly322Asp) and rs17217772 (Asn127Ser) of the hMSH2 gene presented no observable correlation with the risk for BC. Both the rs1799977 A > G and rs63750447 T > A polymorphisms in the hMLH1 gene showed a significant association with a markedly increased risk for BC, while rs4987188 (Gly322Asp) and rs17217772 (Asn127Ser) of the hMSH2 gene were not clearly correlated with BC susceptibility.


Assuntos
Neoplasias da Mama/genética , Proteína 1 Homóloga a MutL/genética , Proteína 2 Homóloga a MutS/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Reparo de Erro de Pareamento de DNA , Feminino , Predisposição Genética para Doença , Genótipo , Humanos , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Adulto Jovem
4.
Int Arch Allergy Immunol ; 181(11): 853-861, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32690852

RESUMO

BACKGROUND: A hallmark of eosinophilic chronic rhinosinusitis with nasal polyps (eCRSwNP) is mucosal eosinophil-predominant inflammation. Nasal nitric oxide (nNO) is a known biomarker of eosinophilic inflammation in the upper airway. However, the utility of nNO measurement in the upper airway remains controversial. The present study aimed to compare the use of other clinical parameters with nNO to prediagnose patients with eCRSwNP from Central China. METHODS: From June 2019 to December 2019, 70 patients with CRSwNP undergoing endoscopic sinus surgery and 30 healthy subjects were enrolled. nNO measurements were performed in all of these subjects. Computed tomography scans, full blood count with differential analysis, and determination of total immunoglobulin E (total IgE) and plasma cytokines were performed before surgery. Receiver operating characteristic curves and logistic regression analysis were used to assess the predictive potential of the clinical parameters. RESULTS: We recruited 24 patients with eCRSwNP and 46 with noneosinophilic CRSwNP (non-eCRSwNP). In patients with eCRSwNP, nNO levels were significantly higher than those in patients with non-eCRSwNP (p < 0.0001). Blood eosinophil percentages and counts, total IgE, and CT-derived ethmoid sinus and maxillary sinus ratio (E/M ratio) were all significantly higher compared with those in patients with non-eCRSwNP (p < 0.05). To diagnose eCRSwNP, the highest area under the curve (0.803) was determined for nNO. At a cutoff of >329 parts per billion (ppb), the sensitivity was 83.30% and the specificity was 71.70%. However, the levels of plasma cytokines Th1/Th2 were not significantly different between the histological types of CRSwNP (p > 0.05). CONCLUSION: Measurement of nNO is useful for the early diagnosis of eCRSwNP.


Assuntos
Pólipos Nasais/diagnóstico , Óxido Nítrico/metabolismo , Testes de Função Respiratória/métodos , Rinite/diagnóstico , Sinusite/diagnóstico , Adulto , China , Doença Crônica , Estudos Transversais , Diagnóstico Precoce , Eosinófilos/patologia , Expiração , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...