Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 12(8): e0183982, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28859165

RESUMO

In the current study, we evaluate the equivalent stiffness of peritubular reinforcement effect (PRE) of porous dentine optimized by the thickness of peritubular dentine (PTD). Few studies to date have evaluated or quantitated the effect of PRE on composite dentine. The miscrostructure of porous dentine is captured by scanning electron microscope images, and then finite element modeling is used to quantitate the deformation and stiffness of the porous dentine structure. By optimizing the radius of PTD and dentine tubule (DT), the proposed FE model is able to demonstrate the effect of peritubular reinforcement on porous dentine stiffness. It is concluded that the dentinal equivalent stiffness is reduced and degraded with the increase of the radius of DT (i.e., porosity) in the certain ratio value of Ep/Ei and certain radius of PTD, where Ep is the PTD modulus and Ei is the intertubular dentine modulus. So in order to ensure the whole dentinal equivalent stiffness is not loss, the porosity should get some value while the Ep/Ei is certain. Thus, PTD prevents the stress concentration around DTs and reduces the risk of DTs failure. Mechanically, the overall role of PTD appears to enhance the stiffness of the dentine composite structure. These results provide some new and significant insights into the biological evolution of the optimal design for the porous dentine microstructure. These findings on the biological microstructure design of dentine materials are applicable to other engineering structural designs aimed at increasing the overall structural strength.


Assuntos
Dentina/ultraestrutura , Dente Molar/ultraestrutura , Adulto , Força Compressiva , Dentina/fisiologia , Feminino , Dureza , Humanos , Masculino , Microscopia Eletrônica de Varredura , Dente Molar/fisiologia , Porosidade , Estresse Mecânico , Extração Dentária
2.
PLoS One ; 11(9): e0158233, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27662186

RESUMO

During eating, the teeth usually endure the sharply temperature changes because of different foods. It is of importance to investigate the heat transfer and heat dissipation behavior of the dentino-enamel junction (DEJ) of human tooth since dentine and enamel have different thermophysical properties. The spatial and temporal temperature distributions on the enamel, dentine, and pulpal chamber of both the human tooth and its discontinuous boundaries, were measured using infrared thermography using a stepped temperature increase on the outer boundary of enamel crowns. The thermal diffusivities for enamel and dentine were deduced from the time dependent temperature change at the enamel and dentine layers. The thermal conductivities for enamel and dentine were calculated to be 0.81 Wm-1K-1 and 0.48 Wm-1K-1 respectively. The observed temperature discontinuities across the interfaces between enamel, dentine and pulp-chamber layers were due to the difference of thermal conductivities at interfaces rather than to the phase transformation. The temperature gradient distributes continuously across the enamel and dentine layers and their junction below a temperature of 42°C, whilst a negative thermal resistance is observed at interfaces above 42°C. These results suggest that the microstructure of the dentin-enamel junction (DEJ) junction play an important role in tooth heat transfer and protects the pulp from heat damage.

3.
Sci Rep ; 5: 9277, 2015 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-25787769

RESUMO

Two-dimensional textured carbon fiber is an excellent electrode material and/or supporting substrate for active materials in fuel cells, batteries, and pseudocapacitors owing to its large surface area, high porosity, ultra-lightness, good electric conductivity, and excellent chemical stability in various liquid electrolytes. And Nickel hydroxide is one of the most promising active materials that have been studied in practical pseudocapacitor applications. Here we report a high-capacitance, flexible and ultra-light composite electrode that combines the advantages of these two materials for pseudocapacitor applications. Electrochemical measurements demonstrate that the 3D hybrid nanostructured carbon fiber-NiCo2O4-Ni(OH)2 composite electrode shows high capacitance, excellent rate capability. To the best of our knowledge, the electrode developed in this work possesses the highest areal capacitance of 6.04 F cm(-2) at the current density of 5 mA cm(-2) among those employing carbon fiber as the conductor. It still remains 64.23% at 40 mA cm(-2). As for the cycling stability, the initial specific capacitance decreases only from 4.56 F cm(-2) to 3.35 F cm(-2) after 1000 cycles under a current density of 30 mA cm(-2).

4.
Analyst ; 137(4): 819-22, 2012 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-22158706

RESUMO

A novel aptamer-based label-free electrochemical impedance spectroscopy biosensor for 17ß-estradiol has been fabricated. The aptamers were firstly immobilized on the gold electrode through Au-S interaction; the aptamer probe was then bound with the addition of 17ß-estradiol to form the estradiol/aptamer complex on the electrode surface. This leads to a significantly larger interfacial electron transfer resistance than that without the addition of 17ß-estradiol. The change in the resistance had a linear relationship with 17ß-estradiol concentration in the range of 1.0 × 10(-8) to 1.0 × 10(-11) mol L(-1), with a detection limit of 2.0 × 10(-12) mol L(-1). The biosensor showed high selectivity to 17ß-estradiol and good stability. The designed biosensor has been applied to detect 17ß-estradiol in human urine with satisfactory results.


Assuntos
Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica/métodos , Estradiol/urina , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Eletroquímica/métodos , Ouro/química , Humanos , Limite de Detecção , Sensibilidade e Especificidade
5.
Anal Chim Acta ; 707(1-2): 57-61, 2011 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-22027119

RESUMO

Herein, a novel sensitive electrochemical sensor for copper(II) based on Cu(I) catalyzed alkyne-azide cycloaddition reaction (CuAAC) is described. The catalyst of Cu(I) species is derived from electrochemical reduction of Cu(II) through bulk electrolysis (BE) with coulometry technique. The propargyl-functionalized ferrocene (propargyl-functionalized Fc) is covalently coupled onto the electrode surface via CuAAC reaction and forms propargyl-functionalized Fc modified gold electrode, which allows a good and stable electrochemical signal. The change of current at peak (dI), detected by differential pulse voltammetry (DPV), exhibits a linear response to the logarithm of Cu(II) concentration in the range of 1.0×10(-14)-1.0×10(-9) mol L(-1). It is also found that the proposed sensor has a good selectivity for copper(II) assay even in the presence of other common metal ions. Additionally, the proposed method has been applied to determine copper(II) in the dairy product (yoghurt) with satisfactory results.


Assuntos
Química Click/métodos , Cobre/análise , Cobre/química , Iogurte/análise , Laticínios/análise , Eletroquímica , Eletrodos/normas , Ouro/análise , Ouro/química
6.
Analyst ; 136(19): 3962-6, 2011 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-21826289

RESUMO

A highly selective and sensitive electrochemical sensor for ascorbic acid (AA) assay has been prepared through Cu(I) catalyzed azide-alkyne cycloaddition reaction (CuAAC). The catalyst, Cu(I) species, is acquired from the reduction of Cu(II) by AA in situ. In the presence of Cu(I) catalyst, the azide modified Au electrode surface is shown to react quantitatively with terminal propargyl-functionalized ferrocene forming 1,2,3-triazoles. The electrochemical response of propargyl-functionalized ferrocene modified Au electrode surface can be monitored using differential pulse voltammetry (DPV) technique. Under optimal conditions, it is found that the current intensity has a linear relationship with the logarithm of AA concentration in the range of 5.0 × 10(-12) to 1.0 × 10(-9) M. Furthermore, the proposed electrochemical sensor shows a good stability (RSD 4.2%), high selectivity and low detection limit for AA detection. In addition, it also demonstrates that the proposed sensor can be applied to detect AA in real urine samples with satisfactory results.


Assuntos
Ácido Ascórbico/análise , Técnicas Eletroquímicas/métodos , Química Click , Técnicas Eletroquímicas/instrumentação , Eletrodos , Ouro/química , Propriedades de Superfície
7.
Chem Commun (Camb) ; 47(32): 9069-71, 2011 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-21755075

RESUMO

A novel catalytic colorimetric assay assisted by nicking endonuclease signal amplification (NESA) was developed. With the signal amplification, the detection limit of the p53 target gene can be as low as 1 pM, which is nearly 5 orders of magnitude lower than that of other previously reported colorimetric DNA detection strategies based on catalytic DNAzyme.


Assuntos
Colorimetria/métodos , Mutação , Proteína Supressora de Tumor p53/genética , DNA/genética , DNA Catalítico/metabolismo , Endonucleases/metabolismo , Genes p53 , Técnicas Genéticas , Humanos , Limite de Detecção
8.
Chem Commun (Camb) ; 47(32): 9080-2, 2011 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-21748195

RESUMO

A DNA electronic logic gate (INHIBIT gate) with good selectivity and reversibility is developed based on using Ag(+) and Cys as inputs and current signal as output.


Assuntos
Computadores Moleculares , Cisteína/análise , DNA de Cadeia Simples/química , Prata/análise , Técnicas Biossensoriais/métodos , Eletrônica , Lógica , Sensibilidade e Especificidade
9.
Chem Commun (Camb) ; 47(28): 8064-6, 2011 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-21681303

RESUMO

A novel signal-on electrochemiluminescent (ECL) biosensor based on adenosine triphosphate (ATP)-induced recombination of split aptamer chips is presented.


Assuntos
Trifosfato de Adenosina/análise , Aptâmeros de Nucleotídeos/metabolismo , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Medições Luminescentes/métodos , Trifosfato de Adenosina/sangue , Trifosfato de Adenosina/metabolismo , Humanos
10.
Biosens Bioelectron ; 26(11): 4326-30, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21596552

RESUMO

Copper(I) species can be acquired from the reduction of copper(II) by ascorbic acid (AA) in situ, and which in turn quantitative catalyze the azides and alkynes cycloaddition reaction. In this study, propargyl-functionalized ferrocene (propargyl-functionalized Fc) has been modified on the electrode through reacting with azide terminal modified Au electrode via copper(I) catalyzed azides and alkynes cycloaddition (CuAAC) reaction. The electrochemical impedance spectroscopy (EIS) measurement has been applied to test the electron transfer resistance of the Au electrode before and after click reaction. The changes of the fractional surface coverage (θ) with different AA concentrations are characterized. It is found that the θ value has a linear response to the logarithm of AA concentration in the range of 5.0 pmol/L to 1.0 nmol/L with the detection limits of 2.6 pmol/L. The sensor shows a good stability and selectivity. And it has been successfully applied to the AA detection in the real samples (urine) with satisfactory results.


Assuntos
Ácido Ascórbico/análise , Técnicas Biossensoriais/métodos , Química Click/métodos , Espectroscopia Dielétrica/métodos , Alcinos/química , Ácido Ascórbico/urina , Azidas/química , Catálise , Cobre , Compostos Ferrosos/química , Ouro , Humanos , Metalocenos , Oxirredução , Pargilina/análogos & derivados , Pargilina/química , Propilaminas/química
11.
Chem Commun (Camb) ; 47(26): 7437-9, 2011 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-21584324

RESUMO

A novel nucleic acid hairpin structure composed of Pb(2+)-dependent DNAzyme and HRP-mimicking DNAzyme was developed. This hairpin structure can be used as a sensor for the detection of Pb(2+) based on colorimetry.


Assuntos
Técnicas Biossensoriais/métodos , DNA Catalítico/metabolismo , Peroxidase do Rábano Silvestre/metabolismo , Chumbo/análise , Chumbo/farmacologia , Sequência de Bases , DNA/genética , DNA/metabolismo , Ativação Enzimática/efeitos dos fármacos , Sequências Repetidas Invertidas
12.
Chem Commun (Camb) ; 47(11): 3129-31, 2011 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-21267487

RESUMO

A simple assay based on electrochemical impedance spectroscopy (EIS) for detection of telomerase activity is developed, and it is demonstrated that the label-free EIS method is capable of detecting the telomerase activity in HeLa cells with a detection limit of 1000 HeLa cells without using any amplification technique.


Assuntos
Espectroscopia Dielétrica/métodos , Telomerase/metabolismo , Sequência de Bases , Eletrodos , Ferricianetos/química , Células HeLa , Humanos , Reação em Cadeia da Polimerase
13.
Anal Chim Acta ; 684(1-2): 121-5, 2011 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-21167993

RESUMO

A highly sensitive and selective electrochemiluminescent (ECL) biosensor for the determination of adenosine was developed. Single DNA (capture DNA) was immobilized on the gold electrode through Au-thiol interaction at first. Another DNA modified with tris(2,2'-bipyridyl) ruthenium(II)-doped silica nanoparticles (Ru-SNPs) that contained adenosine aptamer was then modified on the electrode surface through hybridizing with the capture DNA. In the presence of adenosine, adenosine-aptamer complex is produced rather than aptamer-DNA duplex, resulting with the dissociation of Ru-SNPs-labeled aptamer from the electrode surface and the decrease in the ECL intensity. The decrease of ECL intensity has a direct relationship with the logarithm of adenosine concentration in the range of 1.0×10(-10) to 5.0×10(-6)molL(-1). The detection limit of the proposed method is 3.0×10(-11)molL(-1). The existence of guanosine, cytidine and uridine has little interference with adenosine detection, demonstrating that the developed biosensor owns a high selectivity to adenosine. In addition, the developed biosensor also demonstrates very good reusability, as after being reused for 30 times, its ECL signal still keeps 91% of its original state.


Assuntos
Adenosina/análise , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Nanopartículas/química , Compostos Organometálicos/química , Limite de Detecção , Medições Luminescentes/métodos , Nanopartículas/ultraestrutura , Sensibilidade e Especificidade , Dióxido de Silício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...