Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Surg Res ; 19(1): 68, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218933

RESUMO

BACKGROUND: Continuous passive motion (CPM) is commonly used as a postoperative rehabilitation treatment, along with physical therapy, for postoperative knee rehabilitation. However, the comparison between the two in terms of efficacy in postoperative knee replacement recovery is unclear. PURPOSE: To compare efficacy and safety of combined CPM versus physical therapy alone in postoperative rehabilitation after knee arthroplasty. METHODS: PubMed, Embase, and Web of Science databases were used to retrieve and access clinical studies on the efficacy of CPM compared with physical therapy. Review Manager software was used for study publication bias assessment and data analysis based on inclusion criteria. RESULTS: A total of 6 articles covering 557 patients were included in the study. In terms of range of motion (ROM), passive knee flexion was similar between CPM and physical therapy (PT) (WMD, - 0.17; 95% CI, - 0.98-0.64; p = 0.68). At long-term follow-up, passive knee extension was similar between CPM and physical therapy (PT) (WMD, - 0.28; 95% CI, - 1.47 to - 0.92; I2 = 65%, p =0.65). In addition, CPM generates significantly higher in length of stay (WMD, 0.50; 95% CI, - 0.31 to 0.69; I2 = 3%, p < 0.001). CPM generates significantly higher treatment costs and incurs more care costs relative to physical therapy. CONCLUSION: Compared to PT, combined with CPM failed to significantly improve ROM of the knees and patient's satisfaction. In addition, CPM treatment significantly increased the cost of hospitalization.


Assuntos
Artroplastia do Joelho , Terapia Passiva Contínua de Movimento , Amplitude de Movimento Articular , Humanos , Artroplastia do Joelho/reabilitação , Articulação do Joelho/cirurgia , Modalidades de Fisioterapia
2.
J Orthop Traumatol ; 24(1): 50, 2023 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-37715867

RESUMO

BACKGROUND: Both modular and monoblock tapered fluted titanium (TFT) stems are increasingly being used for revision total hip arthroplasty (rTHA). However, the differences between the two designs in clinical outcomes and complications are not yet clear. Here, we intend to compare the efficacy and safety of modular versus monoblock TFT stems in rTHA. METHODS: PubMed, Embase, Web of Science, and Cochrane Library databases were searched to include studies comparing modular and monoblock implants in rTHA. Data on the survivorship of stems, postoperative hip function, and complications were extracted following inclusion criteria. Inverse variance and Mantel-Haenszel methods in Review Manager (version 5.3 from Cochrane Collaboration) were used to evaluate differences between the two groups. RESULTS: Ten studies with a total of 2188 hips (1430 modular and 758 monoblock stems) were finally included. The main reason for the revision was aseptic loosening. Paprosky type III was the most common type in both groups. Both stems showed similar re-revision rates (modular vs monoblock: 10.3% vs 9.5%, P = 0.80) and Harris Hip Scores (WMD = 0.43, P = 0.46) for hip function. The intraoperative fracture rate was 11.6% and 5.0% (P = 0.0004) for modular and monoblock stems, respectively. The rate of subsidence > 10 mm was significantly higher in the monoblock group (4.5% vs 1.0%, P = 0.003). The application of extended trochanteric osteotomy was more popular in monoblock stems (22.7% vs 17.5%, P = 0.003). The incidence of postoperative complications such as periprosthetic femoral fracture and dislocation was similar between both stems. CONCLUSIONS: No significant difference was found between modular and monoblock tapered stems as regards postoperative hip function, re-revision rates, and complications. Severe subsidence was more frequent in monoblock stems while modular ones were at higher risk of intraoperative fracture. LEVEL OF EVIDENCE: Level III, systematic review of randomized control and non-randomized studies. TRIAL REGISTRATION: We registered our study in the international prospective register of systematic reviews (PROSPERO) (CRD42020213642).


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Fraturas Periprotéticas , Humanos , Reoperação , Bases de Dados Factuais , Fêmur
3.
Front Bioeng Biotechnol ; 11: 1111386, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845182

RESUMO

Objective: The systematic review aimed to determine the potential side effects of antibacterial coatings in orthopaedic implants. Methods: Publications were searched in the databases of Embase, PubMed, Web of Science and Cochrane Library using predetermined keywords up to 31 October 2022. Clinical studies reporting side effects of the surface or coating materials were included. Results: A total of 23 studies (20 cohort studies and three case reports) reporting the concerns about the side effects of antibacterial coatings were identified. Three types of coating materials, silver, iodine and gentamicin were included. All of studies raised the concerns regarding safety of antibacterial coatings, and the occurrence of adverse events was observed in seven studies. The main side effect of silver coatings was the development of argyria. For iodine coatings, only one anaphylactic case was reported as an adverse event. No systemic or other general side effects were reported for gentamicin. Conclusion: Clinical studies on the side effects of antibacterial coatings were limited. Based on the available outcomes, the most reported side effects of antibacterial coatings in clinical use were argyria with silver coatings. However, researchers should always pay attention to the potential side effects of antibacterial materials, such as systematic or local toxicity and allergy.

4.
J Healthc Eng ; 2021: 1233483, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34777727

RESUMO

In this paper, a novel multitask healthcare management recommendation system leveraging the knowledge graph is proposed, which is based on deep neural network and 5G network, and it can be applied in mobile and terminal device to free up medical resources and provide treatment programs. The technique we applied is referred to as KG-based recommendation system. When several experiments have been carried out, it is demonstrated that it is more intelligent and precise in disease prediction and treatment recommendation, similar to the state of the art. Also, it works well in the accuracy and comprehension, which is much higher and highly consistent with the predictions of the theoretical model. The fact that our work involves studies of multitask healthcare management recommendation system, which can contribute to the smart healthcare development, proves to be promising and encouraging.


Assuntos
Redes Neurais de Computação , Reconhecimento Automatizado de Padrão , Atenção à Saúde , Humanos , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...