Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Diabetes Sci Technol ; 17(4): 1056-1065, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35348398

RESUMO

Diabetes mellitus (DM) and obesity are chronic medical conditions associated with significant morbidity and mortality. Accurate macronutrient and energy estimation could be beneficial in attempts to manage DM and obesity, leading to improved glycemic control and weight reduction, respectively. Existing dietary assessment methods are subject to major errors in measurement, are time consuming, are costly, and do not provide real-time feedback. The increasing adoption of smartphones and artificial intelligence, along with the advances in algorithms and hardware, allowed the development of technologies executed in smartphones that use food/beverage multimedia data as an input, and output information about the nutrient content in almost real time. Scope of this review was to explore the various image-based and video-based systems designed for dietary assessment. We identified 22 different systems and divided these into three categories on the basis of their setting for evaluation: laboratory (12), preclinical (7), and clinical (3). The major findings of the review are that there is still a number of open research questions and technical challenges to be addressed and end users-including health care professionals and patients-need to be involved in the design and development of such innovative solutions. Last, there is a clear need that these systems should be validated under unconstrained real-life conditions and that they should be compared with conventional methods for dietary assessment.


Assuntos
Aplicativos Móveis , Humanos , Inteligência Artificial , Multimídia , Avaliação Nutricional , Obesidade , Doença Crônica
2.
Diabetes Care ; 45(10): 2369-2375, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35984478

RESUMO

OBJECTIVE: The efficacy and safety of continuous glucose monitoring (CGM) in adjusting inpatient insulin therapy have not been evaluated. RESEARCH DESIGN AND METHODS: This randomized trial included 185 general medicine and surgery patients with type 1 and type 2 diabetes treated with a basal-bolus insulin regimen. All subjects underwent point-of-care (POC) capillary glucose testing before meals and bedtime. Patients in the standard of care (POC group) wore a blinded Dexcom G6 CGM with insulin dose adjusted based on POC results, while in the CGM group, insulin adjustment was based on daily CGM profile. Primary end points were differences in time in range (TIR; 70-180 mg/dL) and hypoglycemia (<70 mg/dL and <54 mg/dL). RESULTS: There were no significant differences in TIR (54.51% ± 27.72 vs. 48.64% ± 24.25; P = 0.14), mean daily glucose (183.2 ± 40 vs. 186.8 ± 39 mg/dL; P = 0.36), or percent of patients with CGM values <70 mg/dL (36% vs. 39%; P = 0.68) or <54 mg/dL (14 vs. 24%; P = 0.12) between the CGM-guided and POC groups. Among patients with one or more hypoglycemic events, compared with POC, the CGM group experienced a significant reduction in hypoglycemia reoccurrence (1.80 ± 1.54 vs. 2.94 ± 2.76 events/patient; P = 0.03), lower percentage of time below range <70 mg/dL (1.89% ± 3.27 vs. 5.47% ± 8.49; P = 0.02), and lower incidence rate ratio <70 mg/dL (0.53 [95% CI 0.31-0.92]) and <54 mg/dL (0.37 [95% CI 0.17-0.83]). CONCLUSIONS: The inpatient use of real-time Dexcom G6 CGM is safe and effective in guiding insulin therapy, resulting in a similar improvement in glycemic control and a significant reduction of recurrent hypoglycemic events compared with POC-guided insulin adjustment.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/induzido quimicamente , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes , Insulina , Insulina Regular Humana
3.
Diabetes Care ; 44(7): 1641-1646, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34099515

RESUMO

OBJECTIVE: Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient use of CGM has remained investigational, with limited data on its accuracy in the hospital setting. RESEARCH DESIGN AND METHODS: To analyze the accuracy of Dexcom G6, we compared retrospective matched-pair CGM and capillary point-of-care (POC) glucose data from three inpatient CGM studies (two interventional and one observational) in general medicine and surgery patients with diabetes treated with insulin. Analysis of accuracy metrics included mean absolute relative difference (MARD), median absolute relative difference (ARD), and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of POC reference values for blood glucose >100 mg/dL or ≤100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses. RESULTS: A total of 218 patients were included (96% with type 2 diabetes) with a mean age of 60.6 ± 12 years. The overall MARD (n = 4,067 matched glucose pairs) was 12.8%, and median ARD was 10.1% (interquartile range 4.6, 17.6]. The proportions of readings meeting % 15/15, % 20/20, and % 30/30 criteria were 68.7, 81.7, and 93.8%, respectively. CEG analysis showed 98.7% of all values in zones A and B. MARD and median ARD were higher in the case of hypoglycemia (<70 mg/dL) and severe anemia (hemoglobin <7 g/dL). CONCLUSIONS: Our results indicate that CGM technology is a reliable tool for hospital use and may help improve glucose monitoring in non-critically ill hospitalized patients with diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Idoso , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Semin Oncol ; 44(1): 47-56, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28395763

RESUMO

This review comprises a general overview of the impact and risk factors for prostate cancer. Evidenced-based professional society prostate cancer screening guideline recommendations are reviewed, and our approach to a case is presented.


Assuntos
Detecção Precoce de Câncer/métodos , Neoplasias da Próstata/diagnóstico , Exame Retal Digital , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/etiologia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...