Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Emerg Med Int ; 2017: 1375181, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28203462

RESUMO

Introduction. We sought to investigate triathlete adherence to recommendations for follow-up for participants who received event medical care. Methods. Participants of the 2011 Ironman Syracuse 70.3 (Syracuse, NY) who sought evaluation and care at the designated finish line medical tent were contacted by telephone approximately 3 months after the initial encounter to measure adherence with the recommendation to seek follow-up care after event. Results. Out of 750 race participants, 35 (4.6%) athletes received event medical care. Of these 35, twenty-eight (28/35; 80%) consented to participate in the study and 17 (61%) were available on telephone follow-up. Of these 17 athletes, 11 (11/17; 65%) of participants reported that they had not followed up with a medical professional since the race. Only 5 (5/17; 29%) confirmed that they had seen a medical provider in some fashion since the race; of these, only 2 (2/17; 12%) sought formal medical follow-up resulting from the recommendation whereas the remaining athletes merely saw their medical providers coincidentally or as part of routine care. Conclusion. Only 2 (2/17; 12%) of athletes who received event medical care obtained postrace follow-up within a one-month time period following the race. Event medical care providers must be aware of potential nonadherence to follow-up recommendations.

2.
J Sep Sci ; 30(8): 1141-9, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17595949

RESUMO

A novel polydentate C18 silica column was evaluated at an elevated temperature under acidic, basic, and neutral mobile phase conditions using ACN and methanol as the mobile phase organic modifier. The temperature range was 40-200 degrees C. The mobile phase compositions were from 0 to 80% organic-aqueous v/v and the mobile phase pH levels were between 2 and 12. The maximum operating temperature of the column was affected by the amount and type of organic modifier used in the mobile phase. Under neutral conditions, the column showed good column thermal stability at temperatures ranging between 120 and 200 degrees C in methanol-water and ACN-water solvent systems. At pH 2 and 3, the column performed well up to about 160 degrees C at two fixed ACN-buffer compositions. Under basic conditions at elevated temperatures, the column material deteriorated more quickly, but still remained stable up to 100 degrees C at pH 9 and 60 degrees C at pH 10. The results of this study indicate that this novel C18 silica-based column represents a significant advancement in RPLC column technology with enhanced thermal and pH stability when compared to traditional bonded phase silica columns.


Assuntos
Dióxido de Silício/química , Temperatura , Acetonitrilas/química , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Teste de Materiais , Metanol/química , Estrutura Molecular , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...