Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Front Mol Biosci ; 7: 614258, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33585563

RESUMO

Radiology historically has been a leader of digital transformation in healthcare. The introduction of digital imaging systems, picture archiving and communication systems (PACS), and teleradiology transformed radiology services over the past 30 years. Radiology is again at the crossroad for the next generation of transformation, possibly evolving as a one-stop integrated diagnostic service. Artificial intelligence and machine learning promise to offer radiology new powerful new digital tools to facilitate the next transformation. The radiology community has been developing computer-aided diagnosis (CAD) tools based on machine learning (ML) over the past 20 years. Among various AI techniques, deep-learning convolutional neural networks (CNN) and its variants have been widely used in medical image pattern recognition. Since the 1990s, many CAD tools and products have been developed. However, clinical adoption has been slow due to a lack of substantial clinical advantages, difficulties integrating into existing workflow, and uncertain business models. This paper proposes three pathways for AI's role in radiology beyond current CNN based capabilities 1) improve the performance of CAD, 2) improve the productivity of radiology service by AI-assisted workflow, and 3) develop radiomics that integrate the data from radiology, pathology, and genomics to facilitate the emergence of a new integrated diagnostic service.

2.
Med Phys ; 37(11): 5993-6002, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21158311

RESUMO

PURPOSE: A learning-based approach integrating the use of pixel-level statistical modeling and spiculation detection is presented for the segmentation of mammographic masses with ill-defined margins and spiculations. METHODS: The algorithm involves a multiphase pixel-level classification, using a comprehensive group of features computed from regional intensity, shape, and textures, to generate a mass-conditional probability map (PM). Then, the mass candidate, along with the background clutters consisting of breast fibroglandular and other nonmass tissues, is extracted from the PM by integrating the prior knowledge of shape and location of masses. A multiscale steerable ridge detection algorithm is employed to detect spiculations. Finally, all the object-level findings, including mass candidate, detected spiculations, and clutters, along with the PM, are integrated by graph cuts to generate the final segmentation mask. RESULTS: The method was tested on 54 masses (51 malignant and 3 benign), all with ill-defined margins and irregular shape or spiculations. The ground truth delineations were provided by five experienced radiologists. Area overlapping ratio of 0.689 (+/- 0.160) and 0.540 (+/- 0.164) were obtained for segmenting entire mass and margin portion only, respectively. Williams index of area and contour based measurements indicated that the segmentation results of the algorithm agreed well with the radiologists' delineation. CONCLUSIONS: The proposed approach could closely delineate the mass body. Most importantly, it is capable of including mass margin and its spicule extensions which are considered as key features for breast lesion analyses.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Algoritmos , Mama/patologia , Neoplasias da Mama/patologia , Gráficos por Computador , Feminino , Humanos , Modelos Estatísticos , Variações Dependentes do Observador , Radiologia/métodos , Reprodutibilidade dos Testes
3.
Med Phys ; 31(10): 2796-810, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15543787

RESUMO

Our purpose in this work was to develop an automatic boundary detection method for mammographic masses and to rigorously test this method via statistical analysis. The segmentation method utilized a steepest change analysis technique for determining the mass boundaries based on a composed probability density cost function. Previous investigators have shown that this function can be utilized to determine the border of the mass body. We have further analyzed this method and have discovered that the steepest changes in this function can produce mass delineations that include extended projections. The method was tested on 124 digitized mammograms selected from the University of South Florida's Digital Database for Screening Mammography (DDSM). The segmentation results were validated using overlap, accuracy, sensitivity, and specificity statistics, where the gold standards were manual traces provided by two expert radiologists. We have concluded that the best intensity threshold corresponds to a particular steepest change location within the composed probability density function. We also found that our results are more closely correlated with one expert than with the second expert. These findings were verified via Analysis of Variance (ANOVA) testing. The ANOVA tests obtained p-values ranging from 1.03 x 10(-2)-7.51 x 10(-17) for the single observer studies and 2.03 x 10(-2)-9.43 x 10(-4) for the two observer studies. Results were categorized using three significance levels, i.e., p<0.001 (extremely significant), p <0.01 (very significant), and p <0.05 (significant), respectively.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnica de Subtração , Inteligência Artificial , Neoplasias da Mama/classificação , Análise por Conglomerados , Simulação por Computador , Feminino , Humanos , Armazenamento e Recuperação da Informação/métodos , Modelos Biológicos , Modelos Estatísticos , Análise Numérica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
4.
Radiology ; 231(1): 208-14, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-14990808

RESUMO

PURPOSE: To evaluate a noncommercial computer-aided detection (CAD) program for breast cancer detection with screening mammography. MATERIALS AND METHODS: A CAD program was developed for mammographic breast cancer detection. The program was applied to 2,389 patients' screening mammograms at two geographically remote academic institutions (institutions A and B). Thirteen radiologists who specialized in breast imaging participated in this pilot study. For each case, the individual radiologist performed a prospective Breast Imaging Reporting and Data System (BI-RADS) assessment after viewing of the screening mammogram. Subsequently, the radiologist was shown CAD results and rendered a second BI-RADS assessment by using knowledge of both mammographic appearance and CAD results. Outcome analysis of results of examination in patients recalled for a repeat examination, of biopsy, and of 1-year follow-up examination was recorded. Correct detection with CAD included a computer-generated mark indicating a possible malignancy on craniocaudal or mediolateral oblique views or both. RESULTS: Eleven (0.46%) of 2,389 patients had mammographically detected nonpalpable breast cancers. Ten (91%) of 11 (95% CI: 74%, 100%) cancers were correctly identified with CAD. Radiologist sensitivity without CAD was 91% (10 of 11; 95% CI: 74%, 100%). In 1,077 patients, follow-up findings were documented at 1 year. Five (0.46%) patients developed cancers, which were found on subsequent screening mammograms. The area where the cancers developed in two (40%) of these five patients was marked (true-positive finding) by the computer in the preceding year. Because of CAD results, a 9.7% increase in recall rate from 14.4% (344 of 2,389) to 15.8% (378 of 2,389) occurred. Radiologists' recall rate of study patients prior to use of CAD was 31% higher than the average rate for nonstudy cases (10.3%) during the same time period at institution A. CONCLUSION: Performance of the CAD program had a very high sensitivity of 91% (95% CI: 74%, 100%).


Assuntos
Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Neoplasias da Mama/classificação , Carcinoma Ductal de Mama/classificação , Carcinoma Lobular/classificação , Carcinoma Lobular/diagnóstico , Reações Falso-Negativas , Feminino , Seguimentos , Humanos , Mamografia , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Radiologia Intervencionista , Sensibilidade e Especificidade , Estados Unidos/epidemiologia , Saúde da Mulher
5.
IEEE Trans Med Imaging ; 22(9): 1141-51, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12956269

RESUMO

A neural-network-based framework has been developed to search for an optimal wavelet kernel that can be used for a specific image processing task. In this paper, a linear convolution neural network was employed to seek a wavelet that minimizes errors and maximizes compression efficiency for an image or a defined image pattern such as microcalcifications in mammograms and bone in computed tomography (CT) head images. We have used this method to evaluate the performance of tap-4 wavelets on mammograms, CTs, magnetic resonance images, and Lena images. We found that the Daubechies wavelet or those wavelets with similar filtering characteristics can produce the highest compression efficiency with the smallest mean-square-error for many image patterns including general image textures as well as microcalcifications in digital mammograms. However, the Haar wavelet produces the best results on sharp edges and low-noise smooth areas. We also found that a special wavelet whose low-pass filter coefficients are 0.32252136, 0.85258927, 1.38458542, and -0.14548269) produces the best preservation outcomes in all tested microcalcification features including the peak signal-to-noise ratio, the contrast and the figure of merit in the wavelet lossy compression scheme. Having analyzed the spectrum of the wavelet filters, we can find the compression outcomes and feature preservation characteristics as a function of wavelets. This newly developed optimization approach can be generalized to other image analysis applications where a wavelet decomposition is employed.


Assuntos
Algoritmos , Compressão de Dados/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Reconhecimento Automatizado de Padrão , Processamento de Sinais Assistido por Computador , Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Humanos , Mamografia/métodos , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
IEEE Trans Med Imaging ; 21(2): 150-8, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11929102

RESUMO

A multiple circular path convolution neural network (MCPCNN) architecture specifically designed for the analysis of tumor and tumor-like structures has been constructed. We first divided each suspected tumor area into sectors and computed the defined mass features for each sector independently. These sector features were used on the input layer and were coordinated by convolution kernels of different sizes that propagated signals to the second layer in the neural network system. The convolution kernels were trained, as required, by presenting the training cases to the neural network. In this study, randomly selected mammograms were processed by a dual morphological enhancement technique. Radiodense areas were isolated and were delineated using a region growing algorithm. The boundary of each region of interest was then divided into 36 sectors using 36 equi-angular dividers radiated from the center of the region. A total of 144 Breast Imaging-Reporting and Data System-based features (i.e., four features per sector for 36 sectors) were computed as input values for the evaluation of this newly invented neural network system. The overall performance was 0.78-0.80 for the areas (Az) under the receiver operating characteristic curves using the conventional feed-forward neural network in the detection of mammographic masses. The performance was markedly improved with Az values ranging from 0.84 to 0.89 using the MCPCNN. This paper does not intend to claim the best mass detection system. Instead it reports a potentially better neural network structure for analyzing a set of the mass features defined by an investigator.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Mamografia/métodos , Modelos Biológicos , Redes Neurais de Computação , Neoplasias da Mama/classificação , Bases de Dados Factuais , Retroalimentação , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Estatísticos , Reconhecimento Automatizado de Padrão , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...