Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37177499

RESUMO

Prognostic and health management technologies are increasingly important in many fields where reducing maintenance costs is critical. Non-destructive testing techniques and the Internet of Things (IoT) can help create accurate, two-sided digital models of specific monitored objects, enabling predictive analysis and avoiding risky situations. This study focuses on a particular application: monitoring an endodontic file during operation to develop a strategy to prevent breakage. To this end, the authors propose an innovative, non-invasive technique for early fault detection based on digital twins and infrared thermography measurements. They developed a digital twin of a NiTi alloy endodontic file that receives measurement data from the real world and generates the expected thermal map of the object under working conditions. By comparing this virtual image with the real one acquired by an IR camera, the authors were able to identify an anomalous trend and avoid breakage. The technique was calibrated and validated using both a professional IR camera and an innovative low-cost IR scanner previously developed by the authors. By using both devices, they could identify a critical condition at least 11 s before the file broke.

2.
Minerva Dent Oral Sci ; 71(3): 174-179, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34132510

RESUMO

BACKGROUND: To assess the influence of multiple uses on the cyclic flexural fatigue and torsional resistance of Reciproc R25 (REC25) instruments. METHODS: Overall, 256 canals (two for each mandibular molar) were prepared using Reciproc R25 instruments. A total of 96 25-mm-long Reciproc R25 instruments were divided in six groups (N.=8) on the basis of different number of canals shaped: new instruments (control group), one, two, three, four, or six canals shaped during simulated clinical use for other groups respectively. Sixteen files were used for each of the six groups (eight instruments for cyclic fatigue test and eight ones for torsional test). Times to fracture (TtF) for cyclic fatigue and ultimate torsional strength and angle of rotation to fracture for torsional resistance were recorded. Data were statistically evaluated by the analysis of variance (ANOVA) with P<0.05. RESULTS: As for cyclic fatigue resistance, there was no significant difference between new REC25 and REC25 used in one, two and three canals respectively (P>0.05). REC25 used in four and six canals showed significant lower times to fracture when compared with other groups (P<0.05) with REC25 used in six canals showing the significant lowest times to fracture (P<0.05). Considering torsional resistance parameters, no significant difference was observed between the new and used instruments (P>0.05). CONCLUSIONS: REC25 files showed a significant decrease in cyclic fatigue resistance only when used in four or more molar canals while their torsional behavior was not affected by multiple uses.


Assuntos
Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular , Rotação
3.
Sensors (Basel) ; 21(5)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803353

RESUMO

In the present work, a spar-buoy scaled model was designed and built through a "Lab-on-Sea" unit, equipped with an energy harvesting system. Such a system is based on deformable bands, which are loyal to the unit, to convert wave motion energy into electricity by means of piezo patch transducers. In a preliminary stage, the scaled model, suitable for tests in a controlled ripples-type wave motion channel, was tested in order to verify the "fixed-point" assumption in pitch and roll motions and, consequently, to optimize energy harvesting. A special type of structure was designed, numerically simulated, and experimentally verified. The proposed solution represents an advantageous compromise between the lightness of the used materials and the amount of recoverable energy. The energy, which was obtained from the piezo patch transducers during the simulations in the laboratory, was found to be enough to self-sustain the feasible on-board sensors and the remote data transmission system.

4.
Aust Endod J ; 47(1): 20-26, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33169440

RESUMO

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical difference between 90° and 70°; however, its cutting efficiency significantly increased at 45°. There was a significant difference between REC and REB at 45° only. Under these conditions, increased file inclination to 45° and blue heat treatment improved cutting efficiency of reciprocating files.


Assuntos
Níquel , Titânio , Instrumentos Odontológicos , Desenho de Equipamento , Temperatura Alta , Incidência , Teste de Materiais , Preparo de Canal Radicular
5.
Restor Dent Endod ; 43(2): e25, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29765904

RESUMO

OBJECTIVES: To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). MATERIALS AND METHODS: One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal (60° angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. RESULTS: Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. CONCLUSIONS: The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.

6.
J Endod ; 42(1): 156-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26586518

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the torsional and cyclic fatigue resistance of the new Hyflex EDM OneFile (Coltene/Whaledent AG, Altstatten, Switzerland) manufactured by electrical discharge machining and compare the findings with the ones of Reciproc R25 (VDW, Munich, Germany) and WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland). METHODS: One hundred-twenty new Hyflex EDM OneFile (#25/0.08), Reciproc R25, and WaveOne Primary files were used. Torque and angle of rotation at failure of new instruments (n = 20) were measured according to ISO 3630-1 for each brand. Cyclic fatigue resistance was tested measuring the number of cycles to failure in an artificial stainless steel canal with a 60° angle and a 3-mm radius of curvature. Data were analyzed using the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. The fracture surface of each fragment was examined with a scanning electron microscope. RESULTS: The cyclic fatigue of Hyflex EDM was significantly higher than the one of Reciproc R25 and WaveOne Primary (P < .05 and P < .001, respectively). Hyflex EDM showed a lower maximum torque load (P < .05) but a significantly higher angular rotation (P < .0001) to fracture than Reciproc R25 and WaveOne Primary. No significant difference was found comparing the maximum torque load, angular rotation, and cyclic fatigue of Reciproc R25 and WaveOne Primary (P > .05). CONCLUSIONS: The new Hyflex EDM instruments (controlled memory wire) have higher cyclic fatigue resistance and angle of rotation to fracture but lower torque to failure than Reciproc R25 and WaveOne Primary files (M-wire for both files).


Assuntos
Ligas Dentárias , Níquel , Preparo de Canal Radicular/instrumentação , Titânio , Desenho de Equipamento , Falha de Equipamento , Humanos , Rotação , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...