Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 183(1-2): 228-232, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30521032

RESUMO

Personal radiation shielding is likely to play an important role in the strategy for radiation protection of future manned interplanetary missions. There is potential for the successful adoption of wearable shielding devices, readily available in case of accidental exposures or used for emergency operations in low-shielded areas of the habitat, particularly in case of solar particle events (SPEs). Based on optimization of available resources, conceptual models for radiation protection spacesuits have been proposed, with elements made of different materials, and the first prototype of a water-fillable garment was designed and manufactured in the framework of the PERSEO project, funded by the Italian Space Agency, leading to the successful test of such prototype for ease of use and wearability on-board the International Space Station. We present results of Monte Carlo calculations offering a proof-of-principle validation of the shielding efficacy of such prototype in different SPE environments and shielding conditions.


Assuntos
Astronautas , Radiação Cósmica/efeitos adversos , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Voo Espacial , Trajes Espaciais/normas , Relação Dose-Resposta à Radiação , Humanos , Itália , Modelos Teóricos , Método de Monte Carlo , Estudo de Prova de Conceito , Doses de Radiação , Atividade Solar
2.
Life Sci Space Res (Amst) ; 18: 1-11, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30100142

RESUMO

As manned spaceflights beyond low Earth orbit are in the agenda of Space Agencies, the concerns related to space radiation exposure of the crew are still without conclusive solutions. The risk of long-term detrimental health effects needs to be kept below acceptable limits, and emergency countermeasures must be planned to avoid the short-term consequences of exposure to high particle fluxes during hardly predictable solar events. Space habitat shielding cannot be the ultimate solution: the increasing complexity of future missions will require astronauts to protect themselves in low-shielded areas, e.g. during emergency operations. Personal radiation shielding is promising, particularly if using available resources for multi-functional shielding devices. In this work we report on all steps from the conception, design, manufacturing, to the final test on board the International Space Station (ISS) of the first prototype of a water-filled garment for emergency radiation shielding against solar particle events. The garment has a good shielding potential and comfort level. On-board water is used for filling and then recycled without waste. The successful outcome of this experiment represents an important breakthrough in space radiation shielding, opening to the development of similarly conceived devices and their use in interplanetary missions as the one to Mars.


Assuntos
Astronautas , Radiação Cósmica/efeitos adversos , Proteção Radiológica/instrumentação , Trajes Espaciais/normas , Vestuário , Humanos , Modelos Teóricos , Imagens de Fantasmas , Doses de Radiação , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Voo Espacial
3.
Life Sci Space Res (Amst) ; 15: 69-78, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29198316

RESUMO

We present a design study for a wearable radiation-shielding spacesuit, designed to protect astronauts' most radiosensitive organs. The suit could be used in an emergency, to perform necessary interventions outside a radiation shelter in the space habitat in case of a Solar Proton Event (SPE). A wearable shielding system of the kind we propose has the potential to prevent the onset of acute radiation effects in this scenario. In this work, selection of materials for the spacesuit elements is performed based on the results of dedicated GRAS/Geant4 1-dimensional Monte Carlo simulations, and after a trade-off analysis between shielding performance and availability of resources in the space habitat. Water is the first choice material, but also organic compounds compatible with a human space habitat are considered (such as fatty acids, gels and liquid organic wastes). Different designs and material combinations are proposed for the spacesuits. To quantify shielding performance we use GRAS/Geant4 simulations of an anthropomorphic phantom in an average SPE environment, with and without the spacesuit, and we compare results for the dose to Blood Forming Organs (BFO) in Gy-Eq, i.e. physical absorbed dose multiplied by the proton Relative Biological Effectiveness (RBE) for non-cancer effects. In case of SPE occurrence for Intra-Vehicular Activities (IVA) outside a radiation shelter, dose reductions to BFO in the range of 44-57% are demonstrated to be achievable with the spacesuit designs made only of water elements, or of multi-layer protection elements (with a thin layer of a high density material covering the water filled volume). Suit elements have a thickness in the range 2-6 cm and the total mass for the garment sums up to 35-43 kg depending on model and material combination. Dose reduction is converted into time gain, i.e. the increase of time interval between the occurrence of a SPE and the moment the dose limit to the BFO for acute effects is reached. Wearing a radiation shielding spacesuit of the kind we propose, the astronaut could have up to more than the double the time (e.g. almost 6 instead of 2.5 h) to perform necessary interventions outside a radiation shelter during a SPE, his/her exposure remaining within dose limits. An indicative mass saving thanks to the shielding provided by the suits is also derived, calculating the amount of mass needed in addition to the 1.5 cm thick Al module considered for the IVA scenario to provide the same additional shielding given by the spacesuit. For an average 50% dose reduction to BFO this is equal to about 2.5 tons of Al. Overall, our results offer a proof-of-principle validation of a complementary personal shielding strategy in emergency situations in case of a SPE event. Such results pave the way for the design and realization of a prototype of a water-filled garment to be tested on board the International Space Station for wearability. A successful outcome will possibly lead to the further refining of the design of radiation protection spacesuits and their possible adoption in future long-duration manned missions in deep space.


Assuntos
Astronautas , Radiação Cósmica/efeitos adversos , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Trajes Espaciais/normas , Simulação por Computador , Relação Dose-Resposta à Radiação , Humanos , Modelos Teóricos , Doses de Radiação , Lesões por Radiação/etiologia , Eficiência Biológica Relativa
4.
Health Phys ; 94(3): 242-7, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18301097

RESUMO

Shielding is the only practical countermeasure for the exposure to cosmic radiation during space travel. It is well known that light, hydrogenated materials, such as water and polyethylene, provide the best shielding against space radiation. Kevlar and Nextel are two materials of great interest for spacecraft shielding because of their known ability to protect human space infrastructures from meteoroids and debris. We measured the response to simulated heavy-ion cosmic radiation of these shielding materials and compared it to polyethylene, Lucite (PMMA), and aluminum. As proxy to galactic nuclei we used 1 GeV n iron or titanium ions. Both physics and biology tests were performed. The results show that Kevlar, which is rich in carbon atoms (about 50% in number), is an excellent space radiation shielding material. Physics tests show that its effectiveness is close (80-90%) to that of polyethylene, and biology data suggest that it can reduce the chromosomal damage more efficiently than PMMA. Nextel is less efficient as a radiation shield, and the expected reduction on dose is roughly half that provided by the same mass of polyethylene. Both Kevlar and Nextel are more effective than aluminum in the attenuation of heavy-ion dose.


Assuntos
Teste de Materiais/instrumentação , Aceleradores de Partículas/instrumentação , Proteção Radiológica/métodos , Astronave/instrumentação , Humanos , Doses de Radiação , Radiometria
5.
J Air Waste Manag Assoc ; 46(9): 869-82, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8806221

RESUMO

Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.


Assuntos
Filtração , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Tuberculose/prevenção & controle , Ventilação , Humanos
6.
Cardiologia ; 34(8): 695-9, 1989 Aug.
Artigo em Italiano | MEDLINE | ID: mdl-2605580

RESUMO

In 13 patients, affected by hypertrophic obstructive cardiomyopathy (HOCM) and essential hypertension, antihypertensive-efficacy and effects of a new calcium-channel blocker (gallopamil) associated with a diuretic agent (chlorthalidone) on left ventricular systolic and diastolic performance assessed by phonocardiographic methods. The results were compared to those obtained, in the same group of patients, with a selective beta-blocker (atenolol) associated with the same diuretic agent (chlorthalidone). With both therapeutic regimens a statistically significant reduction of systolic and diastolic arterial pressure was observed; both agents were able to reduce hemodynamic gradient in systole which characterize HOCM; however, the treatment with gallopamil plus chlorthalidone determined greater effects on left ventricular diastolic function as compared to the treatment with atenolol plus chlorthalidone; both treatments determined bradycardia.


Assuntos
Atenolol/uso terapêutico , Cardiomiopatia Hipertrófica/tratamento farmacológico , Clortalidona/uso terapêutico , Galopamil/uso terapêutico , Adulto , Idoso , Cardiomiopatia Hipertrófica/complicações , Diástole/efeitos dos fármacos , Avaliação de Medicamentos , Quimioterapia Combinada , Feminino , Ventrículos do Coração , Humanos , Hipertensão/complicações , Hipertensão/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Sístole/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...