Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Physiol Funct Imaging ; 39(2): 135-142, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30325581

RESUMO

It has been suggested that technetium-99m (99mTc)-anti-tumour necrosis factor alpha (TNF-α) scintigraphy (SCI) may be a useful diagnostic tool in Graves' ophthalmopathy (GO). This study evaluated whether orbit total radioactivity uptake on SCI could be used to predict corticosteroid therapy (CorT) responses in active-GO patients. A longitudinal study of patients with active GO defined by Clinical Active Score (CAS) >3/7 was done. Clinical, laboratory and SCI evaluations were performed at baseline and 3 months after concluding intravenous CorT. SCI (planar and tomographic) was assessed after intravenous injection of 10 mCi of 99mTc-anti-TNF-α. Orbits and cerebral hemispheres were defined as regions of interest (ROIs) to enable orbit/hemisphere ROI-ratios of total radioactive uptake. ROI-ratios were considered positive at >2·5. Average total radiation uptake (TRU) was also determined for each orbit (AVGROI ). Clinical, laboratory and SCI data were compared between responders (CAS became inactive) and non-responders to CorT (18 patients). At baseline, AVGROI were higher in active OG orbits (67·3 cps) than in inactive ones (33·6 cps; P<0·05). AVGROI (absolute values) reduced (-29·9 cps) in CorT responders and tended (P = 0·067) to differ from variations occurred in non-responders (+6·9 cps in patients with maintained CAS positivity post-treatment). Higher baseline ROI-ratios (4·9 versus 3·3; P = 0·056) and its pronounced reductions following CorT (-37% versus +56% in non-responders; P = 0·036) tended to be associated with good CorT responses in the subgroup of GO history ≥1 year. SCI showed a good association with active eye disease and may be an additional tool to identify CorT responders.


Assuntos
Adalimumab/administração & dosagem , Corticosteroides/uso terapêutico , Oftalmopatia de Graves/diagnóstico por imagem , Oftalmopatia de Graves/tratamento farmacológico , Compostos Radiofarmacêuticos/administração & dosagem , Tecnécio/administração & dosagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Fator de Necrose Tumoral alfa/antagonistas & inibidores , Feminino , Oftalmopatia de Graves/imunologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Indução de Remissão , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Fator de Necrose Tumoral alfa/imunologia
2.
Magn Reson Imaging Clin N Am ; 26(4): 631-644, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30316472

RESUMO

This article outlines the main findings in prenatal musculoskeletal disorders. Three main technologies are generally used to obtain images within the uterus during pregnancy: ultrasound (US), MR imaging, and computed tomography (CT). Currently, the primary imaging method used for fetal assessment during pregnancy is US because it is patient friendly, useful, cost-effective, and (considered) safe. MR imaging is generally performed when US yields equivocal results because it offers additional information about fetal abnormalities and conditions in situations in which US is unable to provide high-quality images.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças Musculoesqueléticas/diagnóstico por imagem , Doenças Musculoesqueléticas/embriologia , Diagnóstico Pré-Natal/métodos , Feminino , Humanos , Gravidez
3.
Br J Radiol ; 91(1087): 20180126, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29718694

RESUMO

OBJECTIVE:   To evaluate the agreement of three MR elastography (MRE) sequences in patients undergoing liver MRI for clinical care.  Methods:  A cross-sectional retrospective study was performed with 223 patients referred for liver MRI, including 12 patients with liver iron overload. Data obtained with spin-echo (SE) and gradient-echo (GRE) MRE sequences were compared. Multiple linear regression adjusted for the presence of liver fat was also performed to assess the correlation between fat infiltration and stiffness measurements results. Agreement between two SE sequences was assessed in patients with liver iron overload.  Results: We found strong correlation between the GRE sequence and two SE sequences. Spearman's correlation coefficients between the GRE, SE, and SE-EPI MRE sequences in patients with liver R2* <75Hz were 0.74, 0.81, and 0.80. GRE-MRE failed in patients with liver R2* > 75 Hz. In this subgroup, the correlation coefficient between both SE-MRE sequences was 0.97. Liver fat did not interfere with the results. CONCLUSION: In clinical setting, there is a high correlation between the GRE and SE MRE stiffness measurements, independently of the degree of liver fat infiltration measured by PDFF. A strong correlation between SE-MRE sequences is found even in patients with iron overload.  Advances in knowledge: Our study addresses liver iron and fat content simultaneously to describing the technical feasibility and correlation between different MRE sequences in consecutive unselected patients refereed for liver MRI. EPI SE-MRE should be considered an optimal alternative to assess liver fibrosis in patients in whom GRE-MRE failures, such as iron-overloaded, in pediatric, elderly, or severely ill populations.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Abdom Radiol (NY) ; 43(9): 2340-2350, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29450605

RESUMO

AIM: Multiparametric magnetic resonance imaging (mpMRI) may help determine the metabolic profile of patients with obesity and metabolic syndrome in addition to their clinical and laboratory biomarkers for diagnosis and monitoring. An abbreviated mpMRI protocol may be a faster, less-costly, and easier to perform alternative for the diagnosis, treatment, and follow-up of patients with NAFLD and for use in clinical trials. OBJECTIVE: To evaluate an abbreviated mpMRI protocol tailored to analyze quantitative imaging features of patients with obesity and NAFLD and assess its use during treatment. METHODS: This prospective study included patients with obesity and NAFLD to perform a quantitative analysis of liver fat and iron content, stiffness, as well as the visceral adipose tissue (VAT) during the course of a physical exercise-based treatment regimen. RESULTS: Longitudinal improvements in imaging features were observed in patients with good response to treatment, in accordance with improvements in biochemical and anthropometric biomarkers. CONCLUSION: An abbreviated mpMRI protocol consisting of liver fat and iron quantification, MR elastography, and VAT measurements is a feasible, less-costly, and accessible option for screening and monitoring of patients with obesity, NAFLD, and metabolic syndrome.


Assuntos
Terapia por Exercício , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/terapia , Adulto , Idoso , Biomarcadores/análise , Feminino , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Masculino , Síndrome Metabólica/diagnóstico por imagem , Síndrome Metabólica/terapia , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/terapia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...