Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Vasc Interv Radiol ; 23(2): 248-55.e7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22178041

RESUMO

PURPOSE: A phase I dose escalation study was performed with systemically delivered lyso-thermosensitive liposomal doxorubicin (LTLD). The primary objectives were to determine the safe maximum tolerated dose (MTD), pharmacokinetic properties, and dose-limiting toxicity (DLT) of LTLD during this combination therapy. MATERIALS AND METHODS: Subjects eligible for percutaneous or surgical radiofrequency (RF) ablation with primary (n = 9) or metastatic (n = 15) tumors of the liver, with four or fewer lesions as large as 7 cm in diameter, were included. RF ablation was initiated 15 minutes after starting a 30-minute intravenous LTLD infusion. Dose levels between 20 mg/m(2) and 60 mg/m(2) were evaluated. Magnetic resonance imaging, positron emission tomography, and computed tomography were performed at predetermined intervals before and after treatment until evidence of recurrence was seen, administration of additional antitumor treatment was performed, or a total of 3 years had elapsed. RESULTS: DLT criteria were met at 60 mg/m(2), and the MTD was defined as 50 mg/m(2). RF ablation was performed during the peak of the plasma concentration-time curve in an effort to yield maximal drug deposition. LTLD produced reversible, dose-dependent neutropenia and leukopenia. CONCLUSIONS: LTLD can be safely administered systemically at the MTD (50 mg/m(2)) in combination with RF ablation, with limited and manageable toxicity. Further evaluation of this agent combined with RF ablation is warranted to determine its role in the management of liver tumors.


Assuntos
Ablação por Cateter/métodos , Doxorrubicina/administração & dosagem , Hipertermia Induzida/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibióticos Antineoplásicos/administração & dosagem , Terapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Resultado do Tratamento
2.
J Urol ; 186(4): 1281-5, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21849184

RESUMO

PURPOSE: A novel platform was developed that fuses pre-biopsy magnetic resonance imaging with real-time transrectal ultrasound imaging to identify and biopsy lesions suspicious for prostate cancer. The cancer detection rates for the first 101 patients are reported. MATERIALS AND METHODS: This prospective, single institution study was approved by the institutional review board. Patients underwent 3.0 T multiparametric magnetic resonance imaging with endorectal coil, which included T2-weighted, spectroscopic, dynamic contrast enhanced and diffusion weighted magnetic resonance imaging sequences. Lesions suspicious for cancer were graded according to the number of sequences suspicious for cancer as low (2 or less), moderate (3) and high (4) suspicion. Patients underwent standard 12-core transrectal ultrasound biopsy and magnetic resonance imaging/ultrasound fusion guided biopsy with electromagnetic tracking of magnetic resonance imaging lesions. Chi-square and within cluster resampling analyses were used to correlate suspicion on magnetic resonance imaging and the incidence of cancer detected on biopsy. RESULTS: Mean patient age was 63 years old. Median prostate specific antigen at biopsy was 5.8 ng/ml and 90.1% of patients had a negative digital rectal examination. Of patients with low, moderate and high suspicion on magnetic resonance imaging 27.9%, 66.7% and 89.5% were diagnosed with cancer, respectively (p <0.0001). Magnetic resonance imaging/ultrasound fusion guided biopsy detected more cancer per core than standard 12-core transrectal ultrasound biopsy for all levels of suspicion on magnetic resonance imaging. CONCLUSIONS: Prostate cancer localized on magnetic resonance imaging may be targeted using this novel magnetic resonance imaging/ultrasound fusion guided biopsy platform. Further research is needed to determine the role of this platform in cancer detection, active surveillance and focal therapy, and to determine which patients may benefit.


Assuntos
Biópsia por Agulha , Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Vasc Interv Radiol ; 22(4): 515-24, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21354816

RESUMO

PURPOSE: To show utility, accuracy, and clinical outcomes of electromagnetic tracking and multimodality image fusion for guidance of biopsy and radiofrequency (RF) ablation procedures. MATERIALS AND METHODS: A combination of conventional image guidance (ultrasound[US]/computed tomography [CT]) and a research navigation system was used in 40 patients undergoing biopsy or RF ablation to assist in target localization and needle and electrode placement. The navigation system displays electromagnetically tracked needles and US images relative to a preprocedural CT scan. Additional images (prior positron emission tomography [PET] or magnetic resonance [MR] imaging) can be fused with CT as needed. Needle aiming with and without tracking were compared, the utility of navigation for each procedure was assessed, the system's off-target tracking error for two different registration methods was evaluated, and setup time was recorded. RESULTS: The tracking error could be evaluated in 35 of 40 patients. A basic tracking error of 3.8 mm ± 2.3 was shown using skin fiducial markers for registration. The error improved to 2.7 mm ± 1.6 when using prior internal needle positions as additional fiducial markers. Real-time fusion of US with CT and registration with prior PET and MR imaging were successful and provided clinically relevant guidance information, enabling 19 of the 40 procedures. CONCLUSIONS: The spatial accuracy of the navigation system is sufficient to display clinically relevant image guidance information during biopsy and RF ablation. Breath holding and respiratory gating are effective in minimizing the error associated with tissue motion. In 48% of cases, the navigation system provided information crucial for successful execution of the procedure. Fusion of real-time US with CT or prior diagnostic images may enable procedures that are not feasible with standard, single-modality image guidance.


Assuntos
Biópsia por Agulha/métodos , Ablação por Cateter/métodos , Fenômenos Eletromagnéticos , Neoplasias Renais/cirurgia , Neoplasias Hepáticas/cirurgia , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção , Adulto , Idoso , Feminino , Marcadores Fiduciais , Humanos , Neoplasias Renais/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos
4.
J Ultrasound Med ; 30(2): 253-6, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21266564

RESUMO

This case illustrates the ability of electromagnetic tracking navigation to localize difficult targets in real time during biopsy or ablation of lesions that are only transiently apparent on arterial phase computed tomography and may be unapparent on sonography. Readily available technology enabling multimodality registration to sonography allows for the use of positron emission tomographic, magnetic resonance imaging, and computed tomographic information during sonographically guided procedures and examinations.


Assuntos
Biópsia por Agulha/métodos , Campos Eletromagnéticos , Neoplasias Hepáticas/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção/métodos , Feminino , Marcadores Fiduciais , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade
5.
J Urol ; 185(3): 815-20, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21239006

RESUMO

PURPOSE: We determined whether there is a correlation between D'Amico risk stratification and the degree of suspicion of prostate cancer on multiparametric magnetic resonance imaging based on targeted biopsies done with our electromagnetically tracked magnetic resonance imaging/ultrasound fusion platform. MATERIALS AND METHODS: A total of 101 patients underwent 3 Tesla multiparametric magnetic resonance imaging of the prostate, consisting of T2, dynamic contrast enhanced, diffusion weighted and spectroscopy images in cases suspicious for or with a diagnosis of prostate cancer. All prostate magnetic resonance imaging lesions were then identified and graded by the number of positive modalities, including low-2 or fewer, moderate-3 and high-4 showing suspicion on multiparametric magnetic resonance imaging. The biopsy protocol included standard 12-core biopsy, followed by real-time magnetic resonance imaging/ultrasound fusion targeted biopsies of the suspicious magnetic resonance lesions. Cases and lesions were stratified by the D'Amico risk stratification. RESULTS: In this screening population 90.1% of men had a negative digital rectal examination. Mean±SD age was 62.7±8.3 years and median prostate specific antigen was 5.8 ng/ml. Of the cases 54.5% were positive for cancer on protocol biopsy. Chi-square analysis revealed a statistically significant correlation between magnetic resonance suspicion and D'Amico risk stratification (p<0.0001). Within cluster resampling demonstrated a statistically significant correlation between magnetic resonance suspicion and D'Amico risk stratification for magnetic resonance targeted core biopsies and magnetic resonance lesions (p<0.01) CONCLUSIONS: Our data support the notion that using multiparametric magnetic resonance prostate imaging one may assess the degree of risk associated with magnetic resonance visible lesions in the prostate.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco/métodos
6.
J Vasc Interv Radiol ; 21(8 Suppl): S257-63, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20656236

RESUMO

Navigation systems, devices, and intraprocedural software are changing the way interventional oncology is practiced. Before the development of precision navigation tools integrated with imaging systems, thermal ablation of hard-to-image lesions was highly dependent on operator experience, spatial skills, and estimation of positron emission tomography-avid or arterial-phase targets. Numerous navigation systems for ablation bring the opportunity for standardization and accuracy that extends the operator's ability to use imaging feedback during procedures. In this report, existing systems and techniques are reviewed and specific clinical applications for ablation are discussed to better define how these novel technologies address specific clinical needs and fit into clinical practice.


Assuntos
Ablação por Cateter/instrumentação , Radiografia Intervencionista/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Biópsia , Competência Clínica , Fenômenos Eletromagnéticos , Desenho de Equipamento , Humanos , Destreza Motora , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Software , Resultado do Tratamento , Fluxo de Trabalho
7.
J Vasc Interv Radiol ; 18(6): 749-55, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17538137

RESUMO

PURPOSE: Respiratory motion can be a complicating factor during image-guided interventions. The ability to reproduce breath-holds may facilitate safer needle-based procedures. The purpose of this study was to evaluate if respiratory biofeedback decreased variability among breath-holds and if the signals from the respiratory bellows belt can be used to measure target motion. MATERIALS AND METHODS: In phase 1 of the study, a respiratory bellows belt was applied to patients before image-guided interventional procedures. Belt stretch from respiratory motion was converted into voltage readings and displayed on a monitor as biofeedback. Patients were asked to perform inspiratory, expiratory, and midcycle breath-holds with and without the biofeedback. The variability in voltage readings between breath-holds with and without biofeedback was compared. In phase 2, the respiratory bellows belt was used during computed tomography (CT)-guided procedures with the patients blinded to the biofeedback. Voltage readings and CT series numbers were recorded as patients were asked to hold their breath during scans. The variability of CT z-axis targets was compared with the variability of voltage readings. RESULTS: A significant decrease in variability was found during expiratory breath-holds (P = .0083) with trends toward significance with midcycle and inspiratory breath-holds. A positive correlation (Kendall tau = 0.5; P = .024) was shown between CT z-axis and belt stretch variability in subjects who received smaller doses of moderate sedation compared with those who received larger doses or general anesthesia. CONCLUSIONS: Biofeedback may help the patient to have a more consistent breath-hold. The belt could decrease the error and unpredictability from craniocaudal motion of targets during image-guided interventions.


Assuntos
Artefatos , Neoplasias/diagnóstico por imagem , Radiografia Intervencionista/instrumentação , Mecânica Respiratória , Processamento de Sinais Assistido por Computador/instrumentação , Tomografia Computadorizada por Raios X , Adulto , Idoso , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/fisiopatologia , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes
8.
J Vasc Interv Radiol ; 18(1 Pt 1): 9-24, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17296700

RESUMO

Several new image-guidance tools and devices are being prototyped, investigated, and compared. These tools are introduced and include prototype software for image registration and fusion, thermal modeling, electromagnetic tracking, semiautomated robotic needle guidance, and multimodality imaging. The integration of treatment planning with computed tomography robot systems or electromagnetic needle-tip tracking allows for seamless, iterative, "see-and-treat," patient-specific tumor ablation. Such automation, navigation, and visualization tools could eventually optimize radiofrequency ablation and other needle-based ablation procedures and decrease variability among operators, thus facilitating the translation of novel image-guided therapies. Much of this new technology is in use or will be available to the interventional radiologist in the near future, and this brief introduction will hopefully encourage research in this emerging area.


Assuntos
Ablação por Cateter/métodos , Intensificação de Imagem Radiográfica/métodos , Radiologia Intervencionista/métodos , Planejamento da Radioterapia Assistida por Computador , Ablação por Cateter/instrumentação , Análise de Elementos Finitos , Humanos , Radiologia Intervencionista/instrumentação , Software , Tomografia Computadorizada por Raios X
9.
J Vasc Interv Radiol ; 17(12): 1967-9, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17185695

RESUMO

Muscular complications are uncommon but have been reported after radiofrequency (RF) ablation of renal tumors. Ablation of renal lesions near the psoas muscle may result in paresthesia in the distribution of the genitofemoral nerve. The present report describes a case of sensory and muscular dysfunction after RF ablation of a renal lesion lying on top of the psoas muscle that was treated without hydrodissection. To prevent this complication, hydrodissection was effectively used in two other patients during RF ablation of lesions abutting or in close proximity to the psoas muscle.


Assuntos
Ablação por Cateter/efeitos adversos , Complicações Intraoperatórias/prevenção & controle , Neoplasias Renais/cirurgia , Doença de von Hippel-Lindau/cirurgia , Adulto , Feminino , Humanos , Complicações Intraoperatórias/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Masculino , Músculo Esquelético/lesões , Tomografia Computadorizada por Raios X , Doença de von Hippel-Lindau/diagnóstico por imagem
12.
Clin J Oncol Nurs ; 9(3): 346-9, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15973845

RESUMO

Radiofrequency ablation (RFA) has emerged as a safe and predictable technology for treating certain patients with cancer who otherwise have few treatment options. Nurses need to be familiar with all phases of the RFA procedure to create an optimal environment for patients. This article offers a brief review of the RFA procedure and nurses' responsibilities in caring for these patients. Before RFA, nurses should focus on patient education and aggressive hydration. During the procedure, nurses can prevent injury by placing grounding pads appropriately, monitoring vital signs, and medicating patients as needed. After RFA, nurses should assess the skin puncture site, provide adequate pain relief, and, again, hydrate patients. Nurses who care appropriately for RFA recipients may help to improve patient outcomes and make an otherwise frightening procedure more comfortable.


Assuntos
Ablação por Cateter/enfermagem , Neoplasias/cirurgia , Assistência Perioperatória/enfermagem , Humanos , Neoplasias/enfermagem
13.
J Support Oncol ; 2(5): 439-45, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15524075

RESUMO

The purpose of this study was to analyze the feasibility, safety, and efficacy of radiofrequency ablation (RFA) to treat pain from soft tissue neoplasms. RFA was performed on 15 painful soft tissue tumors in 14 patients. Tumors varied in histology and location and ranged in size from 2 to 20 cm. Patient pain was assessed using the Brief Pain Inventory (BPI) at baseline and 1 day, 1 week, 1 month, and 3 months post RFA. All patients had unresectable tumors or were poor operative candidates whose pain was poorly controlled by conventional treatment methods. BPI scores were divided into two categories: pain severity and interference of pain. Although not all scores were statistically significant, all mean scores trended down with increased time post ablation. Based on these outcomes, RFA appears to be a low-risk and well-tolerated procedure for pain palliation in patients with unresectable, painful soft tissue neoplasms. RFA is effective for short-term local pain control and may provide another option for failed chemotherapy or radiation therapy in patients with cancer. However, pain may transiently worsen, and relief is often temporary.


Assuntos
Ablação por Cateter , Dor Intratável/cirurgia , Cuidados Paliativos/métodos , Neoplasias de Tecidos Moles/cirurgia , Humanos , Medição da Dor , Estudos Retrospectivos , Neoplasias de Tecidos Moles/fisiopatologia
14.
Cardiovasc Intervent Radiol ; 27(5): 427-34, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15383844

RESUMO

Radiofrequency ablation (RFA) has been used for over 18 years for treatment of nerve-related chronic pain and cardiac arrhythmias. In the last 10 years, technical developments have increased ablation volumes in a controllable, versatile, and relatively inexpensive manner. The host of clinical applications for RFA have similarly expanded. Current RFA equipment, techniques, applications, results, complications, and research avenues for local tumor ablation are summarized.


Assuntos
Ablação por Cateter , Neoplasias/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos
15.
Cardiovasc Intervent Radiol ; 27(5): 512-5, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15383857

RESUMO

A 45-year-old male with renal cell carcinoma secondary to von-Hippel Lindau (VHL) disease presented for radiofrequency ablation (RFA) of kidney tumors. Due to his prior history of several partial nephrectomies and limited renal reserve, RFA was chosen because of its relatively nephron-sparing nature. A laser guidance device was used to help guide probe placement in an attempt to reduce procedure time and improve targeting accuracy. The device was successful at guiding needle placement, as both tumors were located with a single pass. Follow-up CT scan confirmed accurate needle placement, showing an area of coagulation necrosis covering the previously seen tumor.


Assuntos
Carcinoma de Células Renais/cirurgia , Ablação por Cateter/métodos , Neoplasias Renais/cirurgia , Terapia a Laser , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/etiologia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/etiologia , Terapia a Laser/instrumentação , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Doença de von Hippel-Lindau/complicações , Doença de von Hippel-Lindau/diagnóstico por imagem , Doença de von Hippel-Lindau/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...