Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rhinology ; 62(2): 216-222, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37983015

RESUMO

BACKGROUND: The skin prick test (SPT) is the gold standard for identifying allergic sensitization in individuals suspected of inhalant allergy. A novel device, SPAT or Skin Prick Automated Test, that enables more standardized allergy testing has been developed. Previous research has shown reduced intra-subject variability of histamine wheals by SPAT. OBJECTIVE: This study aimed to evaluate within-test agreement (% of patients with consistent test results) to detect sensitization to common inhalant allergens when a SPT is executed automated by SPAT or by manual SPT (SPMT) procedure. METHODS: The 110 volunteers prospectively enrolled underwent both SPAT and SPMT with 3 pricks of house dust mite, timothy grass and birch, 2 pricks of histamine and 1 prick of glycerol. The proportion of consistent (3x positive â€" 3 x negative) and inconsistent (2x positive/negative â€" 1x positive/negative) test results were analysed. RESULTS: The proportion of inconsistent test results was significantly lower in the SPAT compared to the SPMT group. The delta histamine to control pricks was significantly higher in SPAT compared to SPMT group. Coefficient of variation was lower in SPAT compared to SPMT for house dust mite, timothy grass, birch pollen. Visual analogue scale for discomfort was significantly lower in SPAT compared to SPMT group. CONCLUSION: SPAT showed a 34% reduction in the number of inconsistent test results compared to manual SPT with common inhalant allergens. Patient experience is significantly improved when an allergy test is performed by SPAT compared to a manual SPT.


Assuntos
Histamina , Hipersensibilidade , Humanos , Hipersensibilidade/diagnóstico , Alérgenos , Testes Cutâneos/métodos , Escala Visual Analógica
2.
J Neuroendocrinol ; 23(6): 490-500, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21470317

RESUMO

GPR39, which may function as a Zn(2+) sensor, is a member of the G protein-coupled receptor family that also includes the receptor for the hunger hormone ghrelin. The down-regulation of GPR39 mRNA in adipose tissue of obese type 2 diabetic patients suggests that GPR39 may contribute to the pathogenesis of the disease. The present study aimed to investigate the role of GPR39 in the regulation of energy balance and glucose homeostasis in wild-type (GPR39(+/+) ) and GPR39 knockout mice (GPR39(-/-) ) with obesity-related type 2 diabetes. GPR39 mRNA levels in adipose tissue of fasted GPR39(+/+) mice fed a high-fat diet (HFD) for 30 weeks were reduced and correlated positively with blood glucose levels. Body weight, fat percentage and energy intake were increased in the HFD group but did not differ between both genotypes. Within the HFD group, blood glucose levels were lower in GPR39(-/-) than in GPR39(+/+) mice, despite significant reductions in prandial plasma insulin levels. The latter may not be a result of changes in ß-cell hyperplasia because immunohistochemical staining of pancreata of mice on a HFD showed no differences between genotypes. The lower blood glucose levels may involve alterations in insulin sensitivity as revealed by glucose tolerance tests and respiratory quotient measurements that showed a preference of obese GPR39(-/-) mice for the use of carbohydrates as metabolic fuel. The increase in plasma ghrelin levels in GPR39(-/-) mice fed a HFD may contribute to the alterations in glucose homeostasis, whereas changes in gastric emptying or intestinal Zn(2+) absorption are not involved. The results obtained in the present study suggest that GPR39 plays a role in the pathogenesis of obesity-related type 2 diabetes by affecting the regulation of glucose homeostasis.


Assuntos
Dieta/efeitos adversos , Glucose/metabolismo , Obesidade/etiologia , Receptores Acoplados a Proteínas G/fisiologia , Idade de Início , Animais , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/metabolismo , Dieta Aterogênica , Modelos Animais de Doenças , Predisposição Genética para Doença , Homeostase/genética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Família Multigênica/fisiologia , Obesidade/epidemiologia , Obesidade/genética , Obesidade/metabolismo , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo , Receptores de Grelina/genética , Receptores de Grelina/fisiologia
3.
Med Image Comput Comput Assist Interv ; 11(Pt 1): 393-400, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18979771

RESUMO

A generic supervised segmentation approach is presented. The object is described as a graph where the vertices correspond to landmarks points and the edges define the landmark relations. Instead of building one single global shape model, a priori shape information is represented as a concatenation of local shape models that consider only local dependencies between connected landmarks. The objective function is obtained from a maximum a posteriori criterion and is build up of localized energies of both shape and landmark intensity information. The optimization problem is discretized by searching candidates for each landmark using individual landmark intensity descriptors. The discrete optimization problem is then solved using mean field annealing or dynamic programming techniques. The algorithm is validated for hand bone segmentation from RX datasets and for 3D liver segmentation from contrast enhanced CT images.


Assuntos
Algoritmos , Inteligência Artificial , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Humanos , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Rheumatology (Oxford) ; 47(8): 1179-84, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18515868

RESUMO

OBJECTIVE: GCA carries an increased risk of developing thoracic aortic aneurysms. Previous work with fluorodeoxyglucose (FDG)-PET has shown that the aorta is frequently involved in this type of vasculitis. We wanted to investigate whether there is a correlation between the extent of vascular FDG uptake during the acute phase of GCA and the aortic diameter at late follow-up. METHODS: All patients with biopsy-proven GCA who ever underwent an FDG-PET scan in our centre were asked to undergo a CT scan of the aorta. The diameter of the aorta was measured at six different levels (ascending aorta, aortic arch, descending aorta, abdominal suprarenal, juxtarenal and infrarenal aorta) and the volumes of the thoracic and of the abdominal aorta were calculated. RESULTS: Forty-six patients agreed to participate (32 females, 14 males). A mean of 46.7 +/- 29.9 months elapsed between diagnosis and CT scan. All aortic dimensions were significantly smaller in women than in men, except for the diameter of the ascending aorta. Patients who had an increased FDG uptake in the aorta at diagnosis of GCA, had a significantly larger diameter of the ascending aorta (P = 0.025) and descending aorta (P = 0.044) and a significantly larger volume of the thoracic aorta (P = 0.029). In multivariate analysis, FDG uptake at the thoracic aorta was associated with late volume of the thoracic aorta (P = 0.039). CONCLUSION: GCA-patients with increased FDG uptake in the aorta may be more prone to develop thoracic aortic dilatation than GCA patients without this sign of aortic involvement.


Assuntos
Aorta/patologia , Arterite de Células Gigantes/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aortografia , Dilatação Patológica/diagnóstico por imagem , Feminino , Fluordesoxiglucose F18 , Seguimentos , Arterite de Células Gigantes/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Compostos Radiofarmacêuticos , Recidiva , Fatores de Risco , Fatores Sexuais , Tomografia Computadorizada por Raios X
5.
Med Phys ; 32(12): 3777-85, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475777

RESUMO

The inclusion of organ deformation and movement in radiosurgery treatment planning is of increasing importance as research and clinical applications begin to take into consideration the effects of physiological processes, like breathing, on the shape and position of lesions. In this scenario, the challenge is to localize the target in toto (not only by means of marker sampling) and to calculate the dose distribution as the sum of all the contributions from the positions assumed by the target during the respiratory cycle. The aim of this work is to investigate the use of nonrigid registration for target tracking and dynamic treatment planning, i.e., treatment planning based not on one single CT scan but on multiple CT scans representative of the respiration. Twenty patients were CT scanned at end-inhale and end-exhale. An expert radiation oncologist identified the PTV in both examinations. The two CT data sets per patient were nonrigidly registered using a free-form deformation algorithm based on B-splines. The optimized objective function consisted of a weighted sum of a similarity criterion (Mutual Information) and a regularization factor which constrains the transformation to be locally rigid. Once the transformation was obtained and the registration validated, its parameters were applied to the target only. Finally, the deformed target was compared to the PTV delineated by the radiation oncologist in the other study. The results of this procedure show an agreement between the center of mass as well as volume of the target identified automatically by deformable registration and manually by the radiation oncologist. Moreover, obtained displacements were in agreement with body structure constraints and considerations usually accepted in radiation therapy practice. No significant influence of initial target volume on displacements was found. In conclusion, the proposed method seems to offer the possibility of using nonrigid registrations in radiosurgery treatment planning, even if more cases need to be investigated in order to give a statistical consistency to parameter setup and proposed considerations.


Assuntos
Neoplasias Abdominais/cirurgia , Radiocirurgia/métodos , Radiocirurgia/estatística & dados numéricos , Neoplasias Torácicas/cirurgia , Neoplasias Abdominais/diagnóstico por imagem , Algoritmos , Fenômenos Biofísicos , Biofísica , Bases de Dados Factuais , Humanos , Movimento , Planejamento da Radioterapia Assistida por Computador , Respiração , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
IEEE Trans Med Imaging ; 22(11): 1490-504, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14606682

RESUMO

We propose a voxel-based nonrigid registration algorithm for temporal subtraction of two-dimensional thorax X-ray computed radiography images of the same subject. The deformation field is represented by a B-spline with a limited number of degrees of freedom, that allows global rib alignment to minimize subtraction artifacts within the lung field without obliterating interval changes of clinically relevant soft-tissue abnormalities. The spline parameters are constrained by a statistical deformation model that is learned from a training set of manually aligned image pairs using principal component analysis. Optimization proceeds along the transformation components rather then along the individual spline coefficients, using pattern intensity of the subtraction image within the automatically segmented lung field region as the criterion to be minimized and applying a simulated annealing strategy for global optimization in the presence of multiple local optima. The impact of different transformation models with varying number of deformation modes is evaluated on a training set of 26 images using a leave-one-out strategy and compared to the manual registration result in terms of criterion value and deformation error. Registration quality is assessed on a second set of validation images by a human expert rating each subtraction image on screen. In 85% of the cases, the registration is subjectively rated to be adequate for clinical use.


Assuntos
Algoritmos , Pulmão/diagnóstico por imagem , Movimento (Física) , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Técnica de Subtração , Artefatos , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...